14
DynaPak 3010RNM Version 01102001 ATEX Rev.
YZ Systems, Inc. • 3101 Pollok Drive • Conroe, Texas • USA • 77303 • P: 936.788.5593 • F: 936.788.5720
Turn the count dials to the appropriate number of
pulses you want to count before the sample pump
strokes.
Example: 20 pulses; turn dials to 20.
Press the test button once to load the value into
the memory.
NOTE: if the calculated counter setting is less
than 1 or greater than 99, the pulses per volume
metered will need to be adjusted. This can be
programmed in most flow meters to the desired
rate. If the calculated counter setting is less than
1, increase the pulses per volume metered. If
the calculated counter setting is greater than 99,
decrease the pulses per volume metered.
1. your pump displacement (from .1 to .4cc’s)
=
a.__________
2. your sample cylinder volume in cc’s (300cc, 500cc, etc.)
=
b.__________
3. average flow rate (Metered Volume per day)
=
c.__________
4. sample period in days
=
d.__________
5. pulses per volume metered (pulses per Metered Volume)
=
e.__________
6. counter setting
=
a x c x d x e
(b)
EXAMPLE:
pump displacement
(a.)
=
.2cc
sample cylinder size
(b.)
=
300cc
average flow rate
(c.)
=
100 Metered Volumes per day
sample period
(d.)
=
30 days
pulses per volume metered
(e.)
=
10 pulses per Bbl
counter setting = .2cc x 100 Bbl/day x 30 days x 10 pulses/Bbl =
20 pulses
300 cc
8.2 Z-65/6.1 Set Up:
Calculate the Z65/6.1 counter setting using the
following chart:
3
2
0
9
6
8
7
1
3
2
5
4
0
9
1
6
7
8
5
4
8. Sampler set-up:
Continuous proportional-to-flow sampling