background image

IV. Product packing list

VI. Button instructions

VII. Installation

V. Product instructions

02

03

Name 

       Quantity

Name 

            Quantity

2

1

3

4

5

1. Air outlet                   2. Heated Humidifier 

    3. Hook button 

  4. Power connector            

5. Air filter                   6. Data connection port               7. Micro SD card slot        8. Breathing machine 

9. Start/Stop button   10. Screen           11. Knob 

  12. Button                        13. Humidifying tank

Press this button to start or stop the therapy.

Press the knob to enter the selected interface, to select the items or to save 

the  settings;  also  turn  clockwise  the  knob  to  increase  the  selected  setting 

parameters while turn counter clockwise to decrease.

START

“Start/Stop”button

Knob

Note

   

Fill the humidifier with water which should not exceed the maximum level                 MAX ; 

otherwise the water may enter into the air hose and the device.

    Please fill it with the distilled water, or cool boiled water if no distilled water is available..

2. Take out the humidifying tank from the heated 

    humidifier, and fill it with the  distilled water 

    through the hole on it to an appropriate level 

    below the maximum level.

Host machine   

 1 set 

Heated Humidifier                                    1 set

Air hose 

 

 1 pc 

Power adapter and line                             1 set

User’s manual 

 1 pc 

Mask and accessories (nose mask)          1 set

Kit 

 

 1 set 

Micro SD card (YH- 560/YH-580)                            1 pc

Air filter 

 

 2 pcs                               

1. Connect the heated humidifier with the PAP 

    device.

1

2

       It is suggested to replace the water every day.

13

6

7

12

11

8

9

10

Содержание BreathCare YH-360CPAP

Страница 1: ...certificate or the package for the production date 1030400 0A BreathCare APAP Suzhou Yuyue Medical Technology Co Ltd No 9 Jinfeng Road Suzhou Science Technology Town Suzhou Jiangsu 215163 PRC http ww...

Страница 2: ...sk barotrauma severe lung pneumothorax dehydration cerebrospinal fluid leakage recent intracranial surgery intracranial trauma and etc Dry mouth nosebleeds bloating ear or sinus discomfort eye irritat...

Страница 3: ...wise to decrease START Start Stop button Knob Note Fill the humidifier with water which should not exceed the maximum level MAX otherwise the water may enter into the air hose and the device Please fi...

Страница 4: ...s per hour Used time the time duration for the last therapy h Average pressure the average pressure for the last therapy cmH20 hPa Average leak volume average air leak volume per minute for the last t...

Страница 5: ...n off Level 1 for the lowest level and Level 6 for the highest level Levels 1 6 are equivalent to the following temperatures with the accuracy of 4 respectively Note These temperatures are measured wi...

Страница 6: ...knob to return to the standby interface Fig 6 2 In the APAP mode set the maximum pressure minimum pressure therapy pressure and initial pressure by the same operational order Remark No therapy pressu...

Страница 7: ...return option and press the knob to return to the standby interface Fig 6 2 5 Select the Ramp min 6 Select the Humidity Note Press the START button and the knob at the same to enter into the clinical...

Страница 8: ...ce with a dry and clean cloth Note Ensure that the size of the air filter cotton is proper so as to prevent water or dust from going into the PAP device B Air hose inspection Inspect the air hose for...

Страница 9: ...n the figure The removable cover the partition and the humidifier tank body should be properly installed with their embossing positions aligned 14 15 XII Therapy parameter storage The PAP device shoul...

Страница 10: ...he nose mask type is unqualified The humidify level is low The nose has other disorders The humidify level is too high The temperature difference between inside and outside of the hose is high Decreas...

Страница 11: ...duce the service life of the product When the heated humidifier is used please place the device in a height below the user s head to prevent any water from backflowing into the air hose and the nose m...

Страница 12: ...eated humidifier Plastic hose 1 8m approx PC injection molding stainless steel bottom TPE seal strip 4 20cm H2O hPa adjustable increment 0 5cm H2O hPa 4 20cm H2O hPa adjustable increment 0 5cm H2O hPa...

Страница 13: ...s declaration electromagnetic immunity Immunity test Electrostatic discharge ESD GB T17626 2 6 kV contact 8 kV air 6 kV contact 8 kV air 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycle...

Страница 14: ...MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people...

Страница 15: ...I Warranty Generally Suzhou Yuyue Medical Technology Co Ltd provides the warranty periods for the product and its accessories as follows The warranty for this product applies only for the first time b...

Страница 16: ...ase Date Dealer User Date The following cases are not included in the warranty scope 1 Failure or damage caused by any unauthorized modification and repair by non authorized technicians from yuwell co...

Страница 17: ...nt electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the BreathCare PAP device as recommended below according to t...

Отзывы: