background image

Page 5 of 9

PIAZZA PATIO HEATER

10/04/07

Each Yunca PIAZZA All Seasons Patio Heater is factory set to the appropriate

operating pressure for the gas type that it is factory equipped. If gas pressure

requires adjustment, or a gas type conversion is required, the operating pressure

can be tested at the test nipple on the side of the BM 733 control. Operating

pressure is adjusted at either the LPG or NG in line regulator.

Gas Type, Pressures and jet sizes appear on data plate on the Patio Heater.

When running on Natural Gas the heater can be left mobile and connected to an

approved “bayonet” fitting, or permanently mounted and piped.

To  get  the  maximum  life  from  this  product  we  suggest  that  it  is  stored  in  a

covered position.

If the heater is being installed permanently connected to the supply, a manual

isolating valve should be installed as close as is practical to the appliance.

The All Seasons Patio Heater uses the BM733 control valve, a functional view of

this is shown below.

Legend to functional diagram

1. Valve body, top section

6. Disk valve

11.

Pressure test nipple

2. Valve body, bottom section 7. Flame failure device 12. Main gas inlet

3. Control knob

8. Pilot gas filter

13. Main gas outlet

4. Min. Setting screw

9. Piezo hammer

14. Pilot gas outlet

5. Max. Setting screw

10. Piezo crystal

15. Thermocouple

      Connection.

Содержание PIAZZA

Страница 1: ...Page 1 of 9 PIAZZA PATIO HEATER 10 04 07 PIAZZA All SEASONS PATIO HEATER APRIL 2007 OPERATIONS MAINTENANCE WARRANTY INFORMATION...

Страница 2: ...ld stay with the appliance and is for the reference of the user and service person Only authorised service technicians should undertake any repairs or maintenance on this product It is recommended tha...

Страница 3: ...EGS TO LEG COLUMN SUPPORT 2 BOLT LEGS TO BASE 3 SLIDE CYLINDER ON TO POLE 4 POSITION COLUMN PIPE TO SOCKET 5 ALIGN HOLES SO THAT THE BOLT CAN PASS THROUGH 6 SECURE POLE INTO POSITION USING LOCK NUT 7...

Страница 4: ...ater will effectively heat a radius of around 3M so its position should be chosen to allow efficient use of heat without impeding peoples movement The clearances shown below should be maintained at al...

Страница 5: ...connected to an approved bayonet fitting or permanently mounted and piped To get the maximum life from this product we suggest that it is stored in a covered position If the heater is being installed...

Страница 6: ...to the flame setting required Changing a bottle LPG When the flame turns abnormally yellow and becomes smaller it is time to change the gas bottle To do this simply slide the round cylinder cover up...

Страница 7: ...l must be removed This is done by removing the screws top and bottom and the channel section pilot pipe cover As with all gas appliances regular servicing will improve the trouble free operation of th...

Страница 8: ...y for incidental and consequential damage directly or indirectly sustained or for any loss caused by the application of this product not in accordance with the current printed instructions Our liabili...

Страница 9: ...urchased Installed By If permanent installation Date Yunca Gas PO Box 500 Dunedin 9054 Ph 03 488 4342 Email yuncagas southnet co nz Cut along this line This section must be returned within 10 days of...

Отзывы: