WIRING DIA

GRAM

710541B

 (Replaces 710541A)

Air Handler with Factory Installed Heat (8 kW, 10kW)        

 

X13 MOTOR

Legend

Field 

Wiring

Factory 

Wiring:

Lo

Vo

ltag

e

High 

Vo

ltag

e

NO

TES:

1)  

The blo

wer motor 

speed tap

 

connection ma

y not 

be as sho

wn.

 See 

the Installation 

Instructions.

2)  Disconnect all 

po

wer bef

ore 

servicing.

3)  

Transf

ormer ma

ha

ve a dual v

oltage 

primary tap

. Match

 

the tap position with 

the suppl

y v

oltage

 

used.

4) 

If the Internal wiring 

is replaced,

 use on

ly

 

105

°

C copper wire 

of the same gaug

e.

GREY

ORANGE

ELEMEN

T

ELEMEN

T

BLAC

K

GREY

BLAC

K

GREY

BLUE

ORANGE

POWER

PLUG

LIMI

T

RED

RE

D

RED

RED

BLACK

BLACK

RED

BLACK

RELA

Y

RELA

Y

TERMINAL

BLOCK

(f

or select

models on

ly

)

CIRCUIT

BREAKER

(Cir

cuit breaker

models only)

BLUE

   

 

W2 W1

O

Y/Y2

G R C

X13 MO

TO

R

1 2 3

5

4

TRANSFORMER

24

V

BLA

CK

RED

WHIT

E

BLA

CK

WHITE

FUSE

BLO

WER 

MO

TOR PLUG

C

L

G

N

N = NEUTRAL

G = GR

OUND

L = LINE

C = COMMON

L2

L2

L2 COM

L1

L1

XFMR

X13 COOL

X13 HEAT

24 VA

C

RED

COM

GREY

Y1

C L G N

WHIT

E

X13 COM

RED/BL

AC

K

GREEN/YELLOW

1

2

3

4

5

5 = HI

4 = MED HI

3 = ME

D

2 = MED LO

W

1 = LO

W

SPEED 

TA

PS

5=HI

1=LO

W

2=MED LO

3=ME

D

4=MED HI

C=COM

L=LINE

G=GR

OUND

N=NEUTRAL

P3

HEA

TER KIT 

PLUG

3

2

1

6

5

4

7

GR

OUND

SUPP

LY

 VO

LT

AG

E

RE

D

BLAC

K

¢710541s¤

Figure 12. Wiring Diagram for B5BV Series Electric furnace Equipped With

X13 Motor & 8 or 10 kw heater Kit

Содержание B5BV Series

Страница 1: ...cial notes highlighted in the manual Improper installation of the furnace or failure to follow safety warnings could result in serious injury death or property damage Please read all instructions care...

Страница 2: ...Supply Circuits 10 Control Board 10 Twinning 10 Thermostat Low Voltage Connections 10 Grounding 10 Startup Adjustments 11 Before You Start the Unit 11 Air Circulation Check 11 Running the Blower Conti...

Страница 3: ...ctric Code ANSI NFPA 70 For Canadian installations the electrical connectionsandgroundingshallcomplywiththecurrent Canadian Electrical Code CSA C22 1 and or local codes Installationofequipmentmayrequi...

Страница 4: ...rant tubing This unit should be located with consideration of minimizing the length of the supply and return ducts Refer to the rating plate or Table 3 page 15 for proper circulating airflow data Figu...

Страница 5: ...essure shown on the furnace rating plate The supply air must be delivered to the heated space by duct s secured to the furnace casing running full length and without interruption Circulating Air Suppl...

Страница 6: ...r best sound performance be sure to install all the needed gaskets and grommets around penetrations into the electric furnace such as for electrical wiring Air Filters B5BV series electric furnaces ar...

Страница 7: ...th sheet metal screws Make sure the screws penetrate the sheet metal casing and flanges Tape or seal all seams if required by local code NOTE If an upflow pedestal mounting stand is fabricated in the...

Страница 8: ...nnector and cut out the marked area of the supply air duct NOTE Toallowsomeclearanceforinstallingtheplenum connector cut the opening 1 4 larger the actual cutout drawn 6 Install the duct connector bac...

Страница 9: ...lso be installed in a horizontal application with the unit suspended from the ceiling If suspending the electricfurnacefromtheceiling assembleasupportframe using slotted iron channel and full threaded...

Страница 10: ...ce controls the timing sequence of the elements The board is equipped with a 3 second blower ON delay and a 15 second blower OFF delay in heating and a 40 second blower OFF delay in cooling Twinning E...

Страница 11: ...temperature above room temperature and observe that the blower energizes Checktheairbeingdischargedattheregister is warmer than room temperature 2 Allow the unit to run for several minutes and then se...

Страница 12: ...s recommended that the filter be cleaned or replacedmonthly Newlybuiltorrecentlyrenovatedhomes mayrequiremorefrequentchanginguntiltheconstruction dust has minimized Filter sizes shown in Table 2 are a...

Страница 13: ...B 19 3 4 18 1 4 49 3 8 C 22 1 2 21 56 3 4 3 4 3 4 13 1 7 8 K O 11 8 K O typ 11 4 15 8 17 8 11 4 3 1 4 2 5 8 11 8 K O typ 13 4 K O typ 1 7 8 3 5 8 5 5 8 DETAIL D 3 1 4 2 1 4 15 1 4 13 SUCTION LIQUID W...

Страница 14: ...Transformer Capacitor Circuit Breaker 60A Heating Element Assembly Blower Wheel Blower Housing Motor Control Board Control Board Filter Door Upper Door Assembly Lower Door Assembly Figure 10 B5BV Ser...

Страница 15: ...1576 1783 NOTES 1 Airflow is shown in cfm 5 2 All airflows are measured without filter and with dry coil For filter velocity of 300 ft min subtract 08 external static pressure For wet coil subtract 1...

Страница 16: ...peed tap connection may not be as shown See the Installation Instructions 2 Disconnect all power before servicing 3 Transformer may have a dual voltage primary tap Match the tap position with the supp...

Страница 17: ...GREY BLUE ORANGE POWER PLUG LIMIT RED RED RED RED BLACK BLACK RED BLACK RELAY RELAY TERMINAL BLOCK for select models only CIRCUIT BREAKER Circuit breaker models only BLUE W2 W1 O Y Y2 G R C X13 MOTOR...

Страница 18: ...d 4 If the Internal wiring is replaced use only 105 C copper wire of the same gauge W2 W1 O Y Y2 G R C 4 SPD MOTOR 1 2 3 5 6 4 TRANSFORMER 24V BLACK RED WHITE BLACK WHITE FUSE L2 COM 2 L2 L2 COM L1 VS...

Страница 19: ...ANSFORMER 24V BLACK RED WHITE BLACK WHITE FUSE BLOWER MOTOR PLUG C L G N N NEUTRAL G GROUND L LINE C COMMON L2 L2 L2 COM L1 L1 XFMR X13 COOL X13 HEAT 24 VAC RED COM GREY Y1 C L G N WHITE X13 COM RED B...

Страница 20: ...h B5 Electric Furnace G R C E O Y Thermostat NOTE Jumper W1 W2 together for shorter staging time W2 W1 O Y G R C W2 W1 O Y G R C NOTE Jumper W1 W2 together for shorter staging time Air Handler W2 O W2...

Страница 21: ...21...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...at been calibrated YES NO Is the thermostat level YES NO Is the heat anticipator setting correct YES NO VENTING SYSTEM Is there adequate fresh air supply for ventilation YES NO Vent free from restrict...

Отзывы: