LPM2100 mg NB Module Hardware User Guide
Shanghai Yuge Information Technology Co., Ltd.
- 15 -
30
GPIO_1
IO
Universal input/output port
31
GPIO_2
IO
Universal input/output port
Antenna interface
26
BT_ANT
IO
Bluetooth antenna interface
(reserved)
50
Ω
characteristic
impedance
35
RF_ANT
IO
RF antenna interface
50
Ω
characteristic
impedance
8,21,25
,
44
RESERVED
NC
Leave empty when
not in use
1
,
27
,
34
,
36
,
37
,
40
,
41
GND
Ground signal
3.3 Power interface
The LPM2100 mg series module power connector consists of two parts
:
VBAT is the working power of the module;
VDD_EXT is the internal LDO output IO voltage domain (current load up to 50mA)
for external use
。
3.3.1 VBAT interface
The power supply VBAT has a power-on voltage range of 3.1~4.2V. The module powers
the internal RF and baseband circuitry through the VBAT pin. Under the premise of ensuring
that the VBAT power supply is sufficient, it is recommended to be close to the power input
and put 10pF, 0.1uF,1uF ceramic capacitor and 100uF tantalum capacitor. VBAT PCB traces
are as short and thick as possible
。
Figure 3-2 VBAT power supply