To set alert
1 . Press
[ ALERT ]
to select and display the desired weather alert reading in the sequence
below:
Alert reading Sequence
Setting Range
Display Section
Default Value
Outdoor Temperature High
Alert (current channel)
-40°C ~ 80°C
Outdoor temperature &
humidity
40°C
Outdoor Temperature Low Alert
(current channel)
0°C
Outdoor Humidity High Alert
1% ~ 99%
80%
Outdoor Humidity Low Alert
40%
Indoor Temperature High Alert
-40°C ~ 80°C
Indoor temperature &
humidity
40°C
Indoor Temperature Low Alert
0°C
Indoor Humidity High Alert
1% ~ 99%
80%
Indoor Humidity Low Alert
40%
Wind Speed
0.1m/s ~ 50m/s
Wind direction & speed
17 .2mm/h
Pressure Drop
1hPa ~ 10hPa
Barometer & Rainfall
3hPa
Hourly Rainfall
1mm ~ 1000mm
100mm
Wind Chill Low Alert
-40°C ~ 60°C
Weather index
0°C
Dew point High Alert
-40°C ~ 60°C
10°C
Dew point Low Alert
-10°C
Heat index High Alert
27°C ~ 49°C
35°C
Beaufort scale High Alert
1 ~12
6
UV index Alert
1 ~ 16
10
2 . Under the current alert reading, press and hold
[ ALERT ]
key for 2 seconds to enter alert
setting and the alert reading will flash.
3 . Press
[ GRAPH / ]
or
[ HISTORY / V ]
key to adjust the value or press and hold the key to
change rapidly .
4 . Press
[ ALERT ]
key to save the alert reading then press
[ ALARM ]
key to toggle the
regarding alert on / off .
Alert
ON
Alert on
Alert off
5 . Press any
key on the front side to save and back to normal mode, or it will automatically
back to normal mode after 30 seconds without pressing any key .
To silence the alert alarm:
Press
[ SNOOZE / LIGHT ]
key to silence the alert alarm or let the alarm automatically turn off
after 2 minutes .
NOTE:
-Once the alert is triggered, the alarm will sound for 2 minutes and the related alert icon and
readings will flash.
-If the alert alarm is automatically off after 2 minutes, the alert icon and readings will still keep
flash until the weather reading is out of the alert range.
-The weather alert will sound again when the weather readings falls into the alert range again .