Maintenance procedure 

 

6.1

 

Precautions during installation

   

   

Caution

 

   

 

(1)

When  installing,  confirm  if  the  direction  of  fluid  flow  matches  with  inlet  and 

outlet port of the product respectively. 

If installed in opposite direction, it will not function as designed. 

 

   

(2)

When  installing,  reserve  the  space  shown  for  the  maintenance  and  checking 

(cleaning of the screen). 

It will be impossible to carry out the maintenance and inspection (cleaning of the 
screen). 

 

   

 

(3)

When installing, do not transmit unreasonable load, bending, vibration to the 

products. 

 

 

   

       

The leakage problem may occur.       

(4)

Carry out the connection with pipes properly. 

 

Improper  piping  connection  may  cause  the  leakage  of  fluid  due  to  vibration  or       

other  cause.  With  some  kind  of  fluid,  there  will  be  a  danger  of  personnel  being   
scalded. 

The fluid flowed out of pipe end may cause some material damages. 

 

 

 

 

 

 

(1)

In case installing pressure gauge at backward and forward of strainer, clogging 

can be checked by differential pressure. 

Ref. 8

  Piping example

 

figure 1

 

     

(2)

Install strainer with the cap parts facing downward. 

Ref. 8

Piping example

 

figure 1

 

           

However, install strainer with cap parts facing sideways in case of steam piping 
so that condensate accumulation is minimized. 

Ref. 8

Piping example

 

figure 

2

 

   

(3)

if fluid flows from bottom to top, install a blow valve in order to remove scale 
accumulated at the bottom of riser pipe.

 

Ref. 8

Piping example

 

figure 3

 

                                                               

 

 

6.2

 

Warning and Caution at the point of use

   

   

Warning

 

   

(1)

In case the high temperature of fluid is applied, keep the bare hand off the 

strainer. 

It may cause the personnel being scalded. 

 

   

           
 

(2)

Do not tighten the cap after flowing the fluids to the valve.   

The gasket will be broken and leads to have a leakage. 

 

 

 

 

 

   

Caution

 

   

 

(1)

Use the strainer in condition of maximum pressure loss of below 0.1MPa. Also 

keep cleaning the screen periodically. 

The screen may be damaged. 

 

 

 

 

 

Содержание SY-5

Страница 1: ...hat mishandling this product might cause fatal or serious bodily injury Caution Indicates that mishandling this product might cause bodily injury or material damage Table of Contents 1 Overview 1 2 Sp...

Страница 2: ...compactness and lightweight 2 The strainer is marine type to have maximum filtration area with due consideration of lowering flow rate caused by clogging Steam Cold and hot w Oil Other non dangerous f...

Страница 3: ...25A Rc 1 110 85 32 60 Rc 3 8 1 4 32A Rc 1 1 4 135 95 40 70 Rc 3 8 2 2 40A Rc 1 1 2 145 105 45 75 Rc 3 8 3 4 50A Rc 2 170 120 56 90 Rc 3 8 4 5 The plug size is for the case with a plug Operation No Nam...

Страница 4: ...tallation cost among others Smaller diameter of pipe makes the lower piping cost but the pressure loss will be increased and there are possibilities of abrasion of pipe noise and vibration due to turb...

Страница 5: ...4 EPDT 042b Pressure loss diagram Screen Outside Screen Holes cm2 Screen Outside Screen Holes cm2 Inside Screen Mesh Fluid Water Size Loss of Pressure MPa V Flow Rate L min...

Страница 6: ...ay cause some material damages In case installing pressure gauge at backward and forward of strainer clogging can be checked by differential pressure Ref 8 Piping example figure 1 Install strainer wit...

Страница 7: ...s due to residual pressure or spillage around the valve After checking no internal pressure existed in the strainer by pressure gauge and etc dismount Cap and take out Screen which shall be washed by...

Страница 8: ...product Yoshitake supplies the repair parts for 5 years otherwise individually agreed 3 This warranty does not cover the damage due to any of below 1 Valve seat leakage or malfunction caused by forei...

Отзывы: