manualshive.com logo in svg
background image

-1- 

EPDT-042b

 

 

 

General description 

Strainer is used as dust exhaustion for various pipe lines.      Strainer is necessary 

especially in front of pressure reducing valve, temperature regulator, steam trap, and 
various valves as the reason for maintenance and conservation.       

 

1.

Features 

    (1) The most economical superior type due to compactness and lightweight. 
    (2) The strainer is marine type to have maximum filtration area with due consideration   

of lowering flow rate caused by clogging.

 

     

2.Specifications

 

       

Application

   

Steam

・Air・

Cold and hot w

ater・

Oil

Other non-dangerous fluids  

        Max.Press.           

2.0MPa 

 

        Max.Temp.           

220

 

 

      Material 

     

    Body           

Ductile Cast Iron 

 

   

    Screen     

Stainless Steel 

 

      Connection 

JIS Rc 

 

       

Standard Screen

OutSide Screen

φ

2.5

7.21Holes/cm

InSide Screen80Mesh 

     

20

100Mesh Screen are also available 

     

Plug made of bronze or brass is also available an order.      And, size 10 to 32A 

plug is also available.   

   

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание SY-5

Страница 1: ...hat mishandling this product might cause fatal or serious bodily injury Caution Indicates that mishandling this product might cause bodily injury or material damage Table of Contents 1 Overview 1 2 Sp...

Страница 2: ...compactness and lightweight 2 The strainer is marine type to have maximum filtration area with due consideration of lowering flow rate caused by clogging Steam Cold and hot w Oil Other non dangerous f...

Страница 3: ...25A Rc 1 110 85 32 60 Rc 3 8 1 4 32A Rc 1 1 4 135 95 40 70 Rc 3 8 2 2 40A Rc 1 1 2 145 105 45 75 Rc 3 8 3 4 50A Rc 2 170 120 56 90 Rc 3 8 4 5 The plug size is for the case with a plug Operation No Nam...

Страница 4: ...tallation cost among others Smaller diameter of pipe makes the lower piping cost but the pressure loss will be increased and there are possibilities of abrasion of pipe noise and vibration due to turb...

Страница 5: ...4 EPDT 042b Pressure loss diagram Screen Outside Screen Holes cm2 Screen Outside Screen Holes cm2 Inside Screen Mesh Fluid Water Size Loss of Pressure MPa V Flow Rate L min...

Страница 6: ...ay cause some material damages In case installing pressure gauge at backward and forward of strainer clogging can be checked by differential pressure Ref 8 Piping example figure 1 Install strainer wit...

Страница 7: ...s due to residual pressure or spillage around the valve After checking no internal pressure existed in the strainer by pressure gauge and etc dismount Cap and take out Screen which shall be washed by...

Страница 8: ...product Yoshitake supplies the repair parts for 5 years otherwise individually agreed 3 This warranty does not cover the damage due to any of below 1 Valve seat leakage or malfunction caused by forei...