5. Installation

 

 

5.1 Precaution for installation

 

          Caution

 

1.  Do not disassemble the product unless it is necessary. 

* Disassembly may prevent the product from functioning properly. 

2.  Be sure to remove foreign substances and scale from the piping before connecting the product. 

* Foreign substances and scale may prevent the product from functioning properly. 

3.  Be sure to install a strainer (60 to 80 mesh) at the inlet side of the product.   

* Foreign substances and scale may prevent the product from functioning properly. 

4.  Be sure to install pressure gauges at the inlet and outlet sides of the product for operation check. 

* Failure to follow this notice hampers correct temperature regulation. 

5. 

When installing, check the direction and posture of the product.

 

* Setting the product in a wrong direction or posture prevents the product from functioning properly.

 

6.  Install the product to a place where the ambient temperature does not exceed the set temperature. 

* The ambient temperature beyond the set temperature hampers correct temperature regulation. 

7.  Install a thermometer close to the thermal bulb. 

* Failure to follow this notice hampers correct temperature regulation. 

8.  Make sure that more than 3/4 of the thermal bulb’s total length is in direct contact with the fluid to be 

heated or cooled. 
* Failure to follow this notice hampers correct temperature regulation. 

9.  The bend radius of the capillary tube should be more than 40 mm. Avoid bending at a sharp angle, 

twisting or pulling it with force. 
* Failure to follow this notice may damage the capillary tube and prevent the product from functioning 
properly. 

10. Make sure that the capillary tube is not in contact with steam piping. 

* Failure to follow this notice hampers correct temperature regulation. 

11. 

Do not apply excessive load, torque or vibration to the product.

 

*  Failure  to  follow  this  notice  may  result  in  malfunction  or  a  drastically  shortened  service  life  of  the 
product

.

 

12. 

The body and the sensor are separately packaged.

 

 

5.2 Installation of body

 

(1) 

Be sure not to lose the bellows follower [13] (attached component).

 

(2) 

Install the body to horizontal piping with the handle [12] facing upward.

 

(3) 

Check the direction of the product so that the fluid flowing and the arrow marked on the body [1] are 
in the same direction.

 

(4) 

Be  sure  to  install  pressure  gauges,  a  strainer  and  a  bypass  line  to  the  piping.  (See  “7.5  Piping 
example”) 

 

(5) 

The  pressure  of  heating  or  cooling  fluid  should  be  reduced  with  a  reducing  valve  if  it  exceeds  the 
maximum pressure.

 

(6)  Before stopping operation of the product for an extended period, completely discharge the condensate 

inside the product and piping, and close the stop valves installed at before and after the product. 

(7)  Before leading fluid into the product, be sure to remove foreign substances and scale from the piping 

completely by using a bypass line. 

 

5.3 Installation of thermal bulb

 

(1) 

Although the thermal bulb [20] can be mounted in any posture, make sure that more than 3/4 of its 
total length is in direct contact with the fluid to be heated or cooled.

 

(2) 

Screw in the bushing [18] first, then use the washer of packing [19] to secure the thermal bulb.

 

(3)  The bend radius of the capillary tube [21] should be more than 40 mm. Avoid bending at a sharp angle, 

twisting or pulling it with force. 

(4)  Install a thermometer close to the thermal bulb. 
(5) 

When inserting the thermal bulb into the piping for temperature detection, it should be installed at a 
point where the circulation is best.

 

* The thermal bulb is made of copper and can be easily bent if it bumps against something. Handle 
with care.

 

 

 

 

Содержание OB-30

Страница 1: ...d result in death or serious injury Caution This symbol indicates a hazardous situation that if not avoided may result in minor or moderate injury or may result in only property damage Table of Conten...

Страница 2: ...Pa Material Thermal bulb Copper pipe Nickel chrome plated Capillary tube Copper Flexible tube Stainless steel Standard capillary length 2 m Connection JIS R1 2 screwed Available with thermal well stai...

Страница 3: ...Nominal Size d L Weight kg Capillary length Weight 15A Rc 1 2 75 2 1 2 m 0 6 kg 20A Rc 3 4 80 2 2 25A Rc 1 90 2 4 OB 30U OB 31U OB 30U OB 31U Body mm Sensor Nominal Size d L Weight kg Capillary lengt...

Страница 4: ...lve When the temperature of the bulb lowers the downward force applied to the spindle by the spring 11 opens the valve The set temperature can be adjusted by turning the handle 12 to change the load o...

Страница 5: ...orce to the spindle 7 to open the valve When the temperature of the bulb lowers the downward force applied to the spindle by the spring 11 closes the valve The set temperature can be adjusted by turni...

Страница 6: ...P2 and steam flow rate are 0 2 MPa 0 15 MPa and 20 kg h respectively first find intersection point a of the inlet pressure of 0 2 MPa and the outlet pressure of 0 15 MPa Trace down vertically from th...

Страница 7: ...re and flow rate are 0 3 MPa 0 15 MPa and 1 m3 h respectively first find intersection point a of the differential pressure P of 0 15 MPa 0 3 MPa 0 15 MPa before and after the valve and the flow rate o...

Страница 8: ...Failure to follow this notice hampers correct temperature regulation 11 Do not apply excessive load torque or vibration to the product Failure to follow this notice may result in malfunction or a dra...

Страница 9: ...lve Capillary tube 5 4 Assembly of body and sensor Place the bellows follower 13 which is packaged with the body into the bellows 14 with its flat surface facing downward and then screw it into the lo...

Страница 10: ...r hammer and can heavily damage the main parts of the product Be sure to follow the procedure below 1 Close the stop valves at the inlet and outlet sides of the product Open the bypass stop valve and...

Страница 11: ...t us to retighten the gasket or disassemble the product to replace the part 2 Balance bellows 6 is damaged 2 Please contact us to disassemble the product and replace the part OB 31 OB 31U Trouble Caus...

Страница 12: ...hock to the thermal bulb Warning Inspection must be done by experienced professional or valve manufacturer Completely discharge the pressure inside of the product piping and equipment prior to disasse...

Страница 13: ...improvement without any prior notice After the discontinuation of the product Yoshitake supplies the repair parts for 5 years otherwise individually agreed 3 This warranty does not cover the damage d...

Отзывы: