6. Operating Procedure

 

 

6.1 Precaution for operation

 

 

         

Caution

 

1.  Before leading fluid into the product, close the stop valves at the inlet and outlet of the product and remove 

foreign substances and scale from the piping completely by using a bypass line. When blowing fluid via 
the bypass line, keep fluid temperature from exceeding the withstand temperature of the product. 
* Failure to follow this notice prevents the product from functioning properly due to the ingress of foreign 
substances and scale into the product. Applying fluid exceeding the withstand temperature makes the 
spindle bent and unusable. 

2. 

Adjust set temperature while watching the thermometer with enough time.

 

Failure to follow this notice hampers correct temperature regulation. 

3.  Before stopping operation of the product for an extended period, completely discharge the fluid inside the 

product and piping, and close the stop valves installed at before and after the product.

 

* Failure to follow this notice may cause malfunction due to rusting inside the product and piping. 

4.  If condensate accumulates while the product closes, install a trap to discharge the condensate. 

*Failure to follow this notice may cause malfunction due to rusting inside the product and the pipes. 

 

6.2 Adjustment

 

 

Taking a wrong adjusting procedure may cause hunting, scale problems or water hammer, and can heavily 
damage the main parts of the product. Be sure to follow the procedure below.

 

 

1. 

Close the stop valves at the inlet and outlet sides of the product. Open the bypass stop valve and 
blow fluid through the bypass line with enough time. After discharging, be sure to close the bypass 
stop valve.

 

2. 

Turn the handle [12] and move the indicator to the desired temperature position on the scale. To 
raise  the  temperature,  turn  the  handle  clockwise  (to  direction  of  the  “H”  position).  To  lower  the 
temperature, turn it counterclockwise (to direction of the “L” position).

 

3. 

Slowly open the inlet stop valve to its full open position, and then, open the outlet stop valve little 
by little to its full open position.

 

4. 

Adjust  the  handle  till  the  desired  temperature  is  obtained  while  watching  the  thermometer  with 
enough time.

 

 

[Scale reading and set temperature]

 

Scale reading

 

OB-30, OB-30U (for heating)

 

0-35°C

 

25-70°C

 

40-100°C

 

60-130°C

 

70-150°C

 

0

 

-10°C

 

14°C

 

  28°C

 

 

 

1

 

  5°C

 

30°C

 

  47°C

 

  58°C

 

  67°C

 

2

 

20°C

 

46°C

 

  66°C

 

  81°C

 

  91°C

 

3

 

31°C

 

62°C

 

  86°C

 

105°C

 

119°C

 

4

 

42°C

 

78°C

 

106°C

 

132°C

 

162°C

 

 

Scale reading

 

OB-31, OB-31U (for cooling)

 

0-35°C

 

25-70°C

 

40-100°C

 

0

 

 

 

 

1

 

-14°C

 

11°C

 

23°C

 

2

 

  9°C

 

38°C

 

55°C

 

3

 

32°C

 

65°C

 

94°C

 

4

 

55°C

 

98°C

 

141°C

 

 

The  tables  above  show  the  set  temperature  per  scale  reading  as  a  guide.  Because  the 
temperature varies slightly according to the conditions of use, adjust the handle till the desired 
temperature is obtained.

 

            Warning

 

When the product is used for hot fluid, do not touch the product with bare hands.

 

* The product having hot fluid may scald your skin.

 

Содержание OB-30

Страница 1: ...d result in death or serious injury Caution This symbol indicates a hazardous situation that if not avoided may result in minor or moderate injury or may result in only property damage Table of Conten...

Страница 2: ...Pa Material Thermal bulb Copper pipe Nickel chrome plated Capillary tube Copper Flexible tube Stainless steel Standard capillary length 2 m Connection JIS R1 2 screwed Available with thermal well stai...

Страница 3: ...Nominal Size d L Weight kg Capillary length Weight 15A Rc 1 2 75 2 1 2 m 0 6 kg 20A Rc 3 4 80 2 2 25A Rc 1 90 2 4 OB 30U OB 31U OB 30U OB 31U Body mm Sensor Nominal Size d L Weight kg Capillary lengt...

Страница 4: ...lve When the temperature of the bulb lowers the downward force applied to the spindle by the spring 11 opens the valve The set temperature can be adjusted by turning the handle 12 to change the load o...

Страница 5: ...orce to the spindle 7 to open the valve When the temperature of the bulb lowers the downward force applied to the spindle by the spring 11 closes the valve The set temperature can be adjusted by turni...

Страница 6: ...P2 and steam flow rate are 0 2 MPa 0 15 MPa and 20 kg h respectively first find intersection point a of the inlet pressure of 0 2 MPa and the outlet pressure of 0 15 MPa Trace down vertically from th...

Страница 7: ...re and flow rate are 0 3 MPa 0 15 MPa and 1 m3 h respectively first find intersection point a of the differential pressure P of 0 15 MPa 0 3 MPa 0 15 MPa before and after the valve and the flow rate o...

Страница 8: ...Failure to follow this notice hampers correct temperature regulation 11 Do not apply excessive load torque or vibration to the product Failure to follow this notice may result in malfunction or a dra...

Страница 9: ...lve Capillary tube 5 4 Assembly of body and sensor Place the bellows follower 13 which is packaged with the body into the bellows 14 with its flat surface facing downward and then screw it into the lo...

Страница 10: ...r hammer and can heavily damage the main parts of the product Be sure to follow the procedure below 1 Close the stop valves at the inlet and outlet sides of the product Open the bypass stop valve and...

Страница 11: ...t us to retighten the gasket or disassemble the product to replace the part 2 Balance bellows 6 is damaged 2 Please contact us to disassemble the product and replace the part OB 31 OB 31U Trouble Caus...

Страница 12: ...hock to the thermal bulb Warning Inspection must be done by experienced professional or valve manufacturer Completely discharge the pressure inside of the product piping and equipment prior to disasse...

Страница 13: ...improvement without any prior notice After the discontinuation of the product Yoshitake supplies the repair parts for 5 years otherwise individually agreed 3 This warranty does not cover the damage d...

Отзывы: