Yoshitake AL-6 Скачать руководство пользователя страница 6

                                                                                  ■

EPDT-241

 

 

 

6. Installation 

Fig. 3 reference. 

          Warning 

1.  Do not install any closing device such as a stop valve at inlet and outlet sides of the product. 
2.  Install  an  exhaust  pipe  on  outlet  side  of  the  product,  and  lead  it  to  a  place  where  there  is  no  risk  of 

physical damage even if fluid blows out. 
* Failure to follow this notice may result in injury and scalds in case of fluid blow out. 

3.  Do not disassemble the product unnecessarily. 

* Failure to follow this notice may prevent the product from functioning properly and lead to danger. 

4.  Regarding applicable fluid, viscous fluid that may make fixation of the valve and valve  seat cannot be 

used. 
*  Failure  to  follow  this  notice  may  make  valve  and  valve  seat  fixed  and  prevent  the  product  from 
functioning properly. 

 

          Caution 

1.  Before installing the product, remove foreign substances and scale from the piping. 

*  Failure  to  follow  this  notice  may  prevent  the  product  from  functioning  properly  due  to  foreign 
substance,  etc.  Note  that  the  customer  will  be  required  to  pay  repair  charge  for  any  defect  that 
occurs due to foreign

 

matter. 

2.  When installing the product, confirm the direction of fluid flow with the inlet and outlet of the product 

respectively, and install the product correctly. 
* Failure to follow this notice may prevent the product from functioning properly. 

3.  Install the product vertically with the cap [3] facing upward. 

* Failure to follow this notice may prevent the product from functioning properly. 

4.  Securely support and fasten the pipes (Regarding pipe mount and exhaust pipe, see the below). 

* If an excessive stress is applied to the product, the product may be deformed and not close. 

5.  Lead exhaust pipe to outside of buildings if the product is installed on a place where there is a risk 

that fluid blowout causes alarm activation or contamination of the peripheral equipment. 
* Improper placement may cause contamination of the peripheral equipment. 

6.  Connect the product to the pipes securely. 

* Improper connecting may cause fluid leakage from the connection when vibration is applied, or may   
  cause scalds in case that fluid is hot. 

7.  If  there  is  a  risk  that  condensate  or  rain  water  accumulates  in  exhaust  pipe,  set  a  drain  pipe  in  a 

position where they can be drained. 
* Failure to follow this notice may cause rust and result in malfunction. 

8.  Inner diameters of pipe mount and of exhaust pipe shall be equal to or more than those of each inlet 

and outlet of the product. 
* Failure to follow this notice may result in malfunction or insufficient amount of blowout. 

 

  Pipe mount of safety relief valve 

1.  Pipe mount should have sufficient strength and rigidity against shear stress, compressive stress 

and bending stress which are induced by reaction force in opposite direction of the exhaust 
through the axis of the exhaust pipe.   

2.  Pressure loss in pipe mount leads to decrease in the discharge amount and to unstable 

operation of the product. To prevent them from happening, install the product vertically 
as close as possible to the can body and the header. In addition, install the product in a 
position where maintenance and inspection can be done easily. 

3.  Inner diameter of pipe mount shall be more than that of the product inlet.   

 

  Exhaust pipe of safety relief valve 

1.  Install exhaust pipe and drip pan elbow so that the product cannot be subject to the 

stress caused by thermal expansion of the equipment and by expansion or contraction of 
the exhaust pipe due to thermal action of blowout. 

2.  Inner diameter of exhaust pipe shall be more than that of the product outlet to avoid 

improper back pressure. 

Содержание AL-6

Страница 1: ...ates a potentially hazardous situation that if not avoided could result in death or serious injury Caution This symbol indicates a hazardous situation that if not avoided may result in minor or modera...

Страница 2: ...e seat leakage The product has allowable valve seat leakage and does not close completely valve seat leakage cannot be zero 2 Do not use the product for equipment or device which vibrates excessively...

Страница 3: ...sions mm Weight kg d L H1 H 65A 331 9 65 120 120 479 20 2 80A 441 8 75 130 130 132 493 495 24 0 100A 785 4 100 160 150 152 626 628 44 0 125A 1227 2 125 200 205 207 835 837 88 0 150A 1767 2 150 210 215...

Страница 4: ...e of the safety relief valve decreases when the fluid is released into the atmosphere by the pop action of the valve 5 the force of fluid lift is lowered At this point the repelling force of the sprin...

Страница 5: ...Pa 1 1 1 2 1 3 1 4 1 5 65A 1976 2138 2299 2461 2621 80A 2631 2846 3060 3276 3489 100A 4677 5059 5440 5825 6203 125A 7309 7906 8500 9102 9692 150A Boiler structure standards kg h Nominal size Set press...

Страница 6: ...ngs if the product is installed on a place where there is a risk that fluid blowout causes alarm activation or contamination of the peripheral equipment Improper placement may cause contamination of t...

Страница 7: ...h the open end of the exhaust pipe Failure to follow this notice may result in injury due to discharge Be aware that the product makes a loud noise at start up 4 Do not disassemble the product Please...

Страница 8: ...please contact us for repair at our factory 2 Damage on contact surface between valve 5 and valve seat 4 2 The product needs to be disassembled and its parts need to be replaced Please contact us for...

Страница 9: ...nd cleaned Please contact us 4 There is a back pressure at the piping of the product outlet 4 Remove the back pressure In addition change the piping layout not to allow back pressure 5 The product doe...

Страница 10: ...pair at our factory After lever operation the product does not stop blowing even if letting go of the lever 1 Scale stuck on contact surface between valve 5 and valve seat 4 1 Remove the scale by oper...

Отзывы: