Johnson Controls Unitary Products
7
632151-YTG-A-1010
COOLING CAPACITY - With High Efficiency Motor Furnaces
UNIT
MODEL
FURNACE
MODEL
COIL
MODEL
1
W
COOLING
STAGE
RATED
CFM
NET MBH
SEER
EER
TOTAL
SENSIBLE
1 PH HP WITH HIGH EFFICIENCY FURNACES
2
YZF06013(C)
T*(8,L)X*C16
FC/MC62D
21
1
1115
46.5
29.8
15.00
20.80
2
1610
55.5
39.0
11.65
T*9X*C16
FC/MC62D
21
1
1085
46.5
29.8
15.00
20.80
2
1550
55.5
39.0
11.60
T*9X*C20
FC/MC62D
21
1
1220
47.5
31.2
15.00
20.35
2
1595
55.5
38.5
11.70
T*9X*D20
FC/MC62D
24
1
1240
48.0
31.4
15.00
20.50
2
1610
55.0
38.5
11.50
(Y*(8,L)C/T*8V)*C16
FC/MC62D
21
1
1025
46.5
29.8
15.00
20.80
2
1635
55.5
38.5
11.45
(Y*(8,L)C/T*8V)*C20
FC/MC62D
21
1
1060
46.5
29.8
15.00
20.80
2
1620
55.5
39.0
11.60
(Y*9C/T*9V)*C16
FC/MC62D
21
1
1040
46.5
29.8
15.00
20.80
2
1590
55.5
38.5
11.40
(Y*9C/T*9V)*C20
FC/MC62D
21
1
1040
46.5
29.8
15.00
20.80
2
1655
55.0
38.5
11.25
(Y*9C/T*9V)*D20
FC/MC62D
24
1
1085
46.5
29.8
15.00
20.80
2
1630
55.5
38.5
11.35
T*(8,L)X*C16
FC64D
21
1
1115
48.0
31.2
15.00
21.60
2
1610
57.0
40.0
11.90
T*(8,L)X*C20
FC64D
21
1
835
45.0
28.0
15.00
20.35
2
1665
57.5
40.5
12.00
T*9X*C16
FC64D
21
1
1085
48.0
31.2
15.00
21.60
2
1550
57.0
40.0
11.85
T*9X*C20
FC64D
21
1
1220
49.5
32.6
15.00
21.10
2
1595
57.0
40.0
12.00
T*9X*D20
FC64D
24
1
1240
49.5
32.8
15.00
21.25
2
1610
57.0
40.0
11.85
(Y*(8,L)C/T*8V)*C16
FC64D
21
1
1025
48.0
31.2
15.00
21.60
2
1635
57.0
40.0
11.75
(Y*(8,L)C/T*8V)*C20
FC64D
21
1
1060
48.0
31.2
15.00
21.60
2
1630
57.0
40.0
11.85
(Y*9C/T*9V)*C16
FC64D
21
1
1040
48.0
31.2
15.00
21.60
2
1590
57.0
40.0
11.70
(Y*9C/T*9V)*C20
FC64D
21
1
1040
48.0
31.2
15.00
21.60
2
1655
56.5
40.0
11.50
(Y*9C/T*9V)*D20
FC64D
24
1
1085
48.0
31.2
15.00
21.60
2
1630
57.0
40.0
11.65
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Variable speed furnaces have B.O.D (Blower on Delay) standard.