Installation Procedure
17
Electrical Wiring
WARNING:
INTERCONNECTING WIRES MUST BE WIRED ACCORDING TO FIGURE BELOW. INCORRECT WIRING MAY CAUSE
EQUIPMENT DAMAGE.
Outdoor unit
terminal block
Indoor unit
terminal block
Power supply:380-400V, 3N~,50Hz
Y/G
1 2 3
Y/G
1 2 3
R S T N
SINGLE SPLIT SYSTEM UNITS WIRING DIGRAM
Outdoor unit
terminal block
Indoor unit
terminal block
Power supply:1PH,220-230V~, 50Hz
Y/G
1 2 3
Y/G
1 2 3
L N
Installation Procedure
Test Run
CAUTION!
THIS UNIT WILL BE STARTED INSTANTLY WITHOUT "ON" OPERATION WHEN ELECTRIC POWER IS SUPPLIED.
BE SURE TO EXECUTE "OFF" OPERATION BEFORE ELECTRIC POWER IS DISCONNECTED FOR SERVICING.
This unit has a function of automatic restart system after recovering power stoppage.
1. Before starting test run (for all Heat pump models)
Confirm whether the power source breaker (main switch) of the unit has been turned on for over 12 hrs to energize the
crankcase heater in advance of operation.
2.Test run
Suction pressure at check joint of service valve for gas pipe.
Discharge pressure at check joint on the compressor discharge pipe.
Temperature difference between return air and supply air for indoor unit.
Run the unit continuously for about 30 minutes, and check the following.
MAXI SPLIT SYSTEM UNITS WIRING DIGRAM
Note:
1.The master is the indoor unit which connect to a wired
controller,others are slaves,please purchase wired controller
separately for MAXI system.
2.For one MAXI split system there is only one master.
3.For the MAXI system with 2 or 3 indoor units, the wiring
method is the same with the diagram on the left except for
the indoor units quantity.
4.Make sure that the wire connection for all units in MAXI
system OK before running.
terminal block
1 2 3
R S T N
3N~ 50Hz
380-400V
ERB TYPE
L N
1PH~ 50Hz
220-230V
ERA TYPE
1 2 3
terminal block
Indoor unit 1
master
1 2 3
terminal block
Indoor unit 2
slave
1 2 3
terminal block
Indoor unit 3
slave
1 2 3
terminal block
Indoor unit 4
slave
Содержание YHUJYH(024-060)BAR(S)XA-X(Y)
Страница 3: ......
Страница 19: ...Troubleshooting 18 24K 28K 36K 48K R X 48K S X 48K S Y 60K ...