Maintenance and
Disassembly
Page 70
3. Electrical parts
Note: Remove the panel plate and fan assembly (refer to 1. Panel plate and 2. Fan assembly) before
disassembling electrical parts.
YUFE18BYTM-MO-X, YUFE24BYTM-MO-X, YUFE36BYTM-MO-X
Procedure
Illustration
1) Remove the two screws fixed the
electronic control board (see CJ_
ODU_009).
2) Disconnect the wires connected to
the compressor. (Black wire connects
with terminal 1,blue wire and red
wire connect with the compressor
capacitor) (see CJ_ODU_009)
3) Disconnect the wires connected to
4-way valve.(Blue wires on terminal
2&3) (see CJ_ODU_009)
4) Remove the fixing screw of the
compressor capacitor, then pull it out
(see CJ_ODU_009)
5) Remove the electrical parts (see CJ_
ODU_009)
CJ_ODU_009
Note: This section is for reference only. Actual unit appearance may vary.
Two Fixing Screws
Wires Of Compressor
Connectors for fan motor
Terminal 1 to 4