20
Wiring Schematics cont.
Aurora Advanced Control - 208-230/60/1
Black
Blue
240V
CC
T2
T1
Compressor
C
R
S
Blue
L1
L2
Tan(10)
Capacitor
HWHW
Black
Black
Orange
Orange
SCT
P8
MOTOR
P6
RS485
P7
ZONE
P9
ABC
STEPPER
ANA
ACC2
DH
DIV
NO
COM
K6
NO
COM
K5
C
L1
L1
L2
L2
P12
P10
P5
P11
C
R
(-)
(+)
C
R
(-)
(+)
C
R
(-)
(+)
P4
P2
K1
K2
K3
HA2
HA1
SGI
LOOP
VS DATA
VS PUMP
PUMP
SLAVE
P3
R
V+
C
R
TX
RX
+5
P14
LLT
P1
LAT
FLOW
LWT
EWT
CT2
4
3
CT2
4
3
CT1
2
1
CT1
2
1
Status
G
DISCH
P16
P17
P18
P15
(Aurora Expansion Board)
AXB™
SW1
Modbus Add. ID
Future Use
1
2
3
4
5
ON
OFF
Future Use
Acc 2 – Dip 4
Acc 2 – Dip 5
C
S+
5
C
S
+5
2
1C
C
IN
OUT
T
Suction
Line Temp
5A Circuit Breaker
5A Circuit Breaker
1
2
PB2
2
1
208-230/60/1
Pump
G
Pump
Ext Pump
1/2 hp Total
Blue
Blue
GND
OUT
5DC
1
2
3
SUC P
White
Red
Black
Suction
Pressure
Transducer
Pump Slave
Input/Output
Smart Grid
Home
Automation
Future Use
Accessory 2 Output
1
2
PB1
2
1
208-230/60/1
G
Pump
Load Pump
5A Circuit Breaker
5A Circuit Breaker
OAT Sensor
GeoTank Sensor
OAT
OAT
Tank
Tank
Red (GND)
Red (TS)
Brown (OAT)
Brown (GND)
HydroZone
Controller
GND
TS
OAT
GND
B+
A+
HZC
R
C
O/B
P
V
C1
C2
C3
C4
L
NOTE 2
Black
Red
White
White
Not Used
Violet/White (8)
Violet/White (9)
Black/White (2)
Black/White (1)
Violet (7)
Violet (6)
Black (4)
Black (5)
Orange (12)
Brown (13)
LPR
LPR
NO
NC
COM
Black/White (3)
24 VDC
LPR
NO
NC
COM
Black/White (3)
CC-T1
NOTE 5
Geothermal Tank
Thermostat
Y1
NOTE 6
R
Aurora
Board
Compressor
Common CT
Capacitor
CT
Blue
Blue
Red
Red
Pink
T
Pink
HWHW
HOT WATER
OPTION
T
T
T
T
Brown
Brown
Black
Red
GND
OUT
5DC
1
2
3
White
REFRIGERATION
MONITORING
PERFORMANCE
MONITORING
White
White
Purple
Purple
Gray
Gray
PRESSURE
TRANSDUCER
REFRIGERATION
MONITORING
GND
OUT
5DC
3
2
4
White
3
2
4
Green
Brown
Field Installed Flow Meter
NOTE 8
Notes
1 - Switch blue and red wires for 208V operation.
2 – HydroZone controller is an optional field installed accessory.
3 – Reversing Valve wires not installed on heating only option
4 – FP2 is replaced with a resistor on heating only option
5 – Move black/white(3) wire when HydroZone is not used for pump control to
LPR-NC and CC-T1
6 – When Geothermal Storage Tank is wired directly to the Aurora Board
7 – Low voltage wiring is Class 2
8 – Flow Meter is sent with unit, but needs to be field installed outside the unit.
Auxiliary
Heat CT
Load
Pump CT
Black
Black
Brown
Brown
9 – HydroStat communicating controller is an optional field installed accessory.
Compressor
Common CT
Capacitor
CT
AFFINITY SINGLE STAGE HYDRONIC INSTALLATION MANUAL