16
Electrical Data
Unit
Model
Rated
Voltage
Voltage
Min/Max
Compressor
Load
Pump
Source
Pump
Total Unit
FLA
Min Ckt
Amp
Maximum
Fuse/HACR
RLA
LRA
LRA*
018
208-230/60/1
187/253
9.0
48.0
17
1.8
5.4
16.2
18.5
25
025
208-230/60/1
187/253
14.1
73.0
25.5
1.8
5.4
21.3
24.8
35
040
208-230/60/1
187/253
20.0
115.0
40.3
1.8
5.4
27.2
32.2
50
050
208-230/60/1
187/253
26.4
134.0
46.9
1.8
5.4
33.6
40.2
60
060
208-230/60/1
187/253
30.1
145.0
50.8
1.8
5.4
37.3
44.8
70
075
208-230/60/1
187/253
26.9
145.0
50.8
1.8
5.4
34.1
40.8
60
Notes:All fuses type “D” time delay (or HACR circuit breaker in USA). 1/15/2015
Source pump amps shown are for up to a 1/2 HP pump
Load pump amps shown are for small circulators.
*With optional IntelliStart
Control Box
Load Pump Power Block
Transformer
Run Capacitor
Ground Lug
Load Pump Relay
Compressor Contactor
Circuit Breakers
Source Pump Power Block
Aurora Base Control
Board (ABC)
Aurora Advanced
Control Board (AXB)
Optional IntelliStart
AFFINITY SINGLE STAGE HYDRONIC INSTALLATION MANUAL