1.8.2 Features of the indoor fan gear: standard and with high-speed kit
Ps: Static pressure available [Pa]
P: Consumed power [W]
H.S.D.: High-speed kit
H.S.D.M: High-speed kit with motor included
VIR 25A
Ventilation
gear
Code
Flow m
3
/ h
3600
3900
4250
4590
4900
5200
5500
Ps
P
Ps
P
Ps
P
Ps
P
Ps
P
Ps
P
Ps
P
Standard
₋
172
720
156
790
137
825
117
895
92
965
₋
₋
₋
₋
H.S.D
611991087
267
900
253
980
₋
₋
₋
₋
₋
₋
₋
₋
₋
₋
H.S.D.M
611991088
267
900
253
980
238
1040
222
1100
200
1160
180
1220
158
1290
VIR 40A
Ventilation
gear
Code
Flow m
3
/ h
6000
6500
7000
7500
7800
8000
8300
Ps
P
Ps
P
Ps
P
Ps
P
Ps
P
Ps
P
Ps
P
Standard
₋
153
1070
150
1100
137
1200
118
1305
105
1355
98
1390
85
1440
H.S.D
611991089
242
1280
241
1340
233
1460
217
1585
206
1655
200
1700
188
1760
VIR 45A
Ventilation
gear
Code
Flow m
3
/ h
7200
7800
8400
9000
10500
12000
12600
Ps
P
Ps
P
Ps
P
Ps
P
Ps
P
Ps
P
Ps
P
Standard
₋
150
1375
146
1405
141
1430
130
1490
₋
₋
₋
₋
₋
₋
H.S.D
611991091
203
1575
201
1615
197
1650
188
1720
₋
₋
₋
₋
₋
₋
H.S.D.M
611991090
203
1575
201
1615
197
1650
188
1720
141
2030
65
2400
52
2570
VIR 60A
Ventilation
gear
Code
Flow m
3
/ h
8400
9100
9800
10500
11100
11800
12600
Ps
P
Ps
P
Ps
P
Ps
P
Ps
P
Ps
P
Ps
P
Standard
₋
178
1475
175
1600
160
1750
137
1920
122
2065
90
2270
50
2450
H.S.D
611991092
277
1865
276
2010
266
2170
246
2360
₋
₋
₋
₋
₋
₋
H.S.D.M
611991093
277
1865
276
2010
266
2170
246
2360
234
2510
206
2700
172
2940
VIR 75A
Ventilation
gear
Code
Flow m
3
/ h
11000
12000
12900
13700
15000
16300
17500
Ps
P
Ps
P
Ps
P
Ps
P
Ps
P
Ps
P
Ps
P
Standard
₋
170
1660
156
1830
140
2010
125
2170
97
2450
65
2775
28
3000
H.S.D
611991091
289
2150
282
2380
271
2640
260
2830
₋
₋
₋
₋
₋
₋
H.S.D.M
611991094
289
2150
282
2380
271
2640
260
2830
235
3200
207
3600
175
3930
Installation manual
1
Specifications table
1.8
25