background image

6

Unitary Products Group

550.39-TG5YI

Model

KEU

CFM

Face

Velocity

(FPM)

Sound
Power

dB (10)

12 Watts

Angle of Deflection

Vertical Louvers

1

0° Spread

Horizontal

Louvers

2

Vertical Louvers

1

22

1

2

° Spread

Horizontal

Louvers

2

Vertical Louvers

1

45° Spread

Horizontal

Louvers

2

Throw

(Feet)

3

Spread

(Feet)

3

18°

Throw

(Feet)

3

Spread
(Feet)3

18°

Throw

(Feet)

3

Spread
(Feet)3

18°

Min Max Min Max

Drop

(Feet)

4

Min Max Min Max

Drop

(Feet)

4

Min Max Min Max

Drop

(Feet)4

180

4800

880

26

84 132

32

48

23

12

61

95

38

56

21

11

46

72

73

112

12

6

5400

1000

28

95 149

36

54

24

12

68

107

42

63

22

11

52

81

81

124

12

6

6000

1110

30

106 165

39

59

25

13

76

119

46

69

23

12

57

89

90

138

13

7

6600

1220

33

116 182

43

65

26

13

84

131

50

76

23

12

63

98

99

152

13

7

7200

1330

36

126 199

46

70

27

14

92

143

55

83

24

12

68

107 109 166

14

7

1

Adusting the vertical louvers will vary the throw, the spread and the drop.

2

Adjusting the horizontal louvers will only vary the drop.

3

The velocity of the air will be 125 ft/min. at the minimum distance and 80 ft/min. at the maximum distance.

4

The velocity of the conditioned air at the bottom of the drop will be 50 ft./min. Drafts will occur if the drop extends into the

occupied level of the conditioned space.

SUPPLY AIR PLENUM PERFORMANCE DATA, CFM

Model

KEU

m

3

/s

Face

Velocity

(MPM)

Sound
Power

dB (10)

12 Watts

Angle of Deflection

Vertical Louvers

1

0° Spread

Horizontal

Louvers

2

Vertical Louvers

1

22

1

2

° Spread

Horizontal

Louvers

2

Vertical Louvers

1

45° Spread

Horizontal

Louvers

2

Throw

(Meters)

3

Spread

(Meters)

3

18°

Throw

(Meters)

3

Spread

(Meters)3

18°

Throw

(Meters)3

Spread

(Meters)

3

18°

Min Max Min Max

Drop

(Meters)

4

Min Max Min Max

Drop

(Meters)

4

Min Max Min Max

Drop

(Meters)4

180

2.26

268

26

25.5 40.1 9.7 14.6 7.0

3.6 18.5 28.9 11.6 17.0 6.4

3.3 14.0 22.0 22.2 34.0 3.6

1.8

2.55

304

28

28.9 45.3 10.9 16.4 7.3

3.6 20.7 32.5 12.8 19.2 6.7

3.3 15.8 24.6 24.6 37.7 3.6

1.8

2.83

337

30

32.2 50.1 11.9 18.0 7.6

4.0 23.1 36.2 14.0 21.0 7.0

3.6 17.3 27.0 27.4 42.0 4.0

2.1

3.11

371

33

35.3 55.3 13.1 20.0 7.9

4.0 25.5 40.0 15.2 23.1 7.0

3.6 19.2 29.8 30.1 46.2 4.0

2.1

3.40

404

36

38.3 60.5 14.0 21.3 8.2

4.3 28.0 43.5 16.7 25.2 7.3

3.6 20.7 32.5 33.1 50.5 4.3

2.1

1

Adusting the vertical louvers will vary the throw, the spread and the drop.

2

Adjusting the horizontal louvers will only vary the drop.

3

The velocity of the air will be 125 ft./min. at the minimum distance and 80 ft./min. at the maximum distance.

4

The velocity of the conditioned air at the bottom of the drop will be 50 ft./min. Drafts will occur if the drop extends into the

occupied level of the conditioned space.

SUPPLY AIR PLENUM PERFORMANCE DATA,

Motor

(kW/HP)

Blower

Range
(RPM)

Adjustable Motor Pulley

Fixed Blower Pulley

Belt

Pitch Dia

(mm/in.)

Bore

(mm/in.)

Pitch Dia.

(mm/in.)

Bore

(mm/in/)

Designation

Pitch Lg.

(mm/in.)

2.2 / 3

615/800

86 - 112/

3.4 - 4.4

22.2 /

7

8

203 / 8.0

25 / 1

A54

1405 / 55.3

BLOWER MOTOR AND DRIVE DATA

M

3

/S

Содержание SUNLINE 2000 KEU180

Страница 1: ...can be selected to precisely match the cooling and heating requirements of the conditioned space These heaters are designed for easy field installation over the supply air opening of the unit Every he...

Страница 2: ...Air Grille and Base accessories can be applied on arrangement b The Supply Air Plenum Return Air Grille and Suspension accessories can be applied on arrangement c Heater Model UL Test Voltage Nominal...

Страница 3: ...ower Model Used On l s GPM m3 s CFM Entering Water Temperature Minus Entering Air Temperature C F 21 70 32 90 43 110 54 130 66 150 1HW0451 KEU180 0 95 15 2 3 4800 135 5 463 175 1 598 215 8 737 257 4 8...

Страница 4: ...SP2 IWG OUTPUT BHP INPUT kW ESP2 IWG OUTPUT BHP INPUT kW 4800 CFM 5400 CFM 6000 CFM 6600 CFM 7200 CFM 600 0 46 1 44 1 34 0 30 1 68 1 56 0 11 1 96 1 80 615 0 55 1 54 1 43 0 40 1 79 1 64 0 22 2 08 1 90...

Страница 5: ...04 0 05 0 06 0 07 Return Air Grille 0 04 0 05 0 06 0 07 0 08 Hot Water Coil 0 18 0 22 0 26 0 03 0 34 Steam Coil 0 15 0 18 0 22 0 26 0 30 Static resistance pascal Unit Model Accessory m3 s 2 26 2 55 2...

Страница 6: ...rtical Louvers1 0 Spread Horizontal Louvers2 Vertical Louvers1 221 2 Spread Horizontal Louvers2 Vertical Louvers1 45 Spread Horizontal Louvers2 Throw Meters 3 Spread Meters 3 0 18 Throw Meters 3 Sprea...

Страница 7: ...lectric Heater 10 kW 37 6 83 16 kW 29 9 66 26 kW 32 2 71 36 kW 33 5 74 Hot Water Coil Tube OD mm inches 1 2 12 7 copper Rows Deep 2 Fins per 25mm 1 in 8 aluminum Face Area square meters square feet 0...

Страница 8: ...ll dimension of the unit will vary if an electric heater a supply air plenum or a base is used 2 This dimension is required for removal of the DX coil Only 660mm 26 in is required for normal servicing...

Страница 9: ...tting on the electric heat accessory Connect the power wiring to the fuse block in the heater control box Route the control wires through the 22 2mm 7 8 in openings and connect them to the ter minals...

Страница 10: ...hrough 0 AWG Accessory Model Nom kW Heater Dimensions mm inches A B C D E F G H K L M 2HS04501050 2HS04501650 2HS04502650 2HS04503650 10 16 26 36 692 271 4 641 251 4 362 141 4 25 1 102 4 13 1 2 140 51...

Страница 11: ...11 550 39 TG5YI TERMINALS ON BLOCK 3TB OF THE BLOWER UNIT TERMINALS ON 1 STAGE COOLING THERMOSTAT 2TH13700424 FIELD WIRING Cooling only CONTROL WIRING Units with steam or hot water coil AC Units with...

Страница 12: ...o change without notice Printed in U S A Copyright by York International Corporation 2001 All Rights Reserved 5005 York Drive 550 39 TG5Y 0601 Supersedes 550 39 TG5Y 0501 Norman OK 73069 Unitary Produ...

Отзывы: