background image

035-19671-002 Rev. A (0704)

2

Unitary Products Group

7.

NEVER . . .Store flammable materials of any kind near your fur-
nace. Gasoline, solvents, and other volatile liquids should be
stored only in approved containers outside your home. These
materials vaporize easily and are extremely dangerous.

8.

NEVER . . .Store cleaning materials near your furnace. Materials
such as bleaches, detergents, powdered cleansers, etc., can
cause corrosion of the heat exchangers.

9.

NEVER . . . Use the area around your furnace as a storage area
for items which could block the normal flow of air. This flow of air is
required for ventilation of the various furnace components.

INSTRUCTIONS FOR EXAMINING THE FURNACE 

INSTALLATION

It is the owner’s responsibility to ensure that an annual inspection of the
entire heating portion of the unit is made by a qualified service agency.
Examine the furnace as outlined below in steps “1 - 6” before each
heating season. Use Figure 3 for visual reference.

1.

Examine the heat exchanger, vent pipe, combustion air passes-
ges, vent connectors and chimney to be sure they are clear and
free of obstructions.

2.

Examine the vent pipe making sure it is firmly in place, that it
slopes slightly upward and is physically sound without holes and
all of the connections are secure.

3.

Examine the return-air duct connections to make sure they are
physically sound, sealed to the furnace casing, and the ducts ter-
minate outside the space containing the furnace.

4.

Examine the furnace casing making sure the physical support is
sound without sagging, cracks or gaps. Examine the furnace base
making sure it is physically sound without cracks, gaps or sagging
and has a good seal.

5.

Examine the furnace casing for obvious signs of deterioration.

6.

Examine the burner flames to make sure they are in good adjust-
ment. Refer to the pictorial sketch shown in Figure 2 as a compari-
son to the actual flame.

 FIGURE 1: 

Component Locations

FIRE OR EXPLOSION HAZARD

This furnace is designed and approved for use with Nat-
ural Gas and (LP) Propane Gas ONLY. DO NOT BURN
ANY LIQUID FUEL OR SOLID FUEL IN THIS FURNACE.

Burning any unapproved fuel will result in damage to the
furnace heat exchanger, which could result in Fire, Per-
sonal Injury, and/or Property Damage.

BLOWER

PRESSURE
SWITCH

BURNER
ASSEMBLY

GAS VALVE

VENT PIPE

INDUCER
ASSEMBLY

INDUCER
MOTOR

INTEGRATED
CONTROL

R

E

P

L

A

C

E

R

E

P

L

A

C

E

SCRE

W

SCRE

W

PM

C
HI

O
F
F

O
F
F

ON

ROLLOUT
SWITCH

ELECTRICAL
JUNCTION BOX

LIMIT CONTROL

SAFETY SHUTOFF
SWITCH

 FIGURE 2: 

Burner Flame Drawing

BLUE CONE PORTION OF FLAME SHOULD
ENTER HEAT EXCHANGER TUBE

 FIGURE 3: 

Furnace Examination Checkpoints

4 EXAMINE

FURNACE
CASING

6

5

3

4

3

1

6

EXAMINE
RETURN AIR
DUCT
CONNECTION

REMOVE
PANEL
TO EXAMINE
BURNER
FLAMES

EXTERNAL HEAT EXCHANGER INTERNAL

VENT COMBUSTION AIR PIPE. MUST

REMOVE PANEL TO EXAMINE.

EXAMINE ENTIRE
FURNACE CASING
SHOWN IN ALL
DRAWINGS

EXAMINE
RETURN AIR
DUCT
CONNECTION
(side or bottom)

REMOVE
PANEL
TO EXAMINE
BURNER
FLAMES

EXAMINE EXTERNAL
VENT PIPE

EXAMINE
FURNACE
CASING

BURNER DOOR

BLOWER DOOR

Содержание FC8T

Страница 1: ...all gas con trols control system parts electrical parts that have been wet or the furnace if deemed necessary FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious...

Страница 2: ...pace containing the furnace 4 Examine the furnace casing making sure the physical support is sound without sagging cracks or gaps Examine the furnace base making sure it is physically sound without cr...

Страница 3: ...water Operating Instructions 1 STOP Read the safety information above 2 Set the thermostat to the lowest setting 3 Turn off all electric power to the appliance 4 Remove burner door 5 Move gas control...

Страница 4: ...ve a bottom or side return air duct using the following method a If the return air filter is on the left or right side of the furnace it is a side return b If the air filter is on the bottom of the fu...

Страница 5: ...rner assembly 7 Burners may be cleaned by rinsing in hot water 8 Reassemble the burners in the reverse order Cleaning the Heat Exchanger Lower Heat Exchanger Access 1 Turn off the electrical power to...

Страница 6: ...acts of 2LP The High Fire Pressure Switch The Control checks that 2LP is closed The Gas Valve is energized on 2nd Stage High Fire The Control simultaneously de energizes the Heat Low relay and energiz...

Страница 7: ...to the fur nace SLOW GREEN FLASH Normal operation SLOW AMBER FLASH Normal first stage operation with call for heat AMBER PULSE Normal second stage operation with call for heat 3 FLASHES AMBER Indicate...

Страница 8: ...MINUTE AUTOMATIC RESET FROM LOCKOUT This control includes a watch dog type circuit that will reset from a lockout condition after 60 minutes Operational faults 6 7 8 will be reset This provides protec...

Страница 9: ...W INDUCER LOW STAGE PRESSURE SWITCH HSI 1ST STAGE MAIN VALVE FLAME SENSE LOW CIRCULATOR HEAT SPEED 1ST STAGE LOW PRESSURE SWITCH CLOSE RECOGNITION HSI WARM UP 17 SEC IGNITION ACTIVATION PERIOD 4 SEC T...

Страница 10: ...19671 002 Rev A 0704 10 Unitary Products Group SECTION III REPLACEMENT PARTS LIST 2 4 11 9 5 3 6 8 7 12 13 16 17 26 53 28 42 39 29 38 43 21 25 32 33 35 31 27 23 22 44 30 24 18 20 12A 7 35 24 36 12 19...

Страница 11: ...NGER ASS Y 25 MANIFOLD GAS 26 PANEL UPPER ACCESS 27 PAN BASE 28 PANEL BLOWER ACCESS 29 PANEL TOP 30 WRAPPER INSULATED 31 CHANNEL TOE PLATE 32 BRACKET TOP DOOR 33 BRACKET BOTTOM DOOR 34 RACK FILTER 35...

Страница 12: ...650 78 N1 1V 1PS0314 1CB0314 COMBUSTIBLE FLOOR BASE FOR DOWNFLOW UNITS ALL 14 1 2 A CABINETS 1CB0317 ALL 17 1 2 B CABINETS 1CB0321 ALL 21 C CABINETS 1CB0324 ALL 24 1 2 D CABINETS REPLACEMENT PART CON...

Страница 13: ...035 19671 002 Rev A 0704 Unitary Products Group 13 SECTION IV WIRING DIAGRAM FIGURE 9 Wiring Diagram...

Страница 14: ...035 19671 002 Rev A 0704 14 Unitary Products Group NOTES...

Страница 15: ...035 19671 002 Rev A 0704 Unitary Products Group 15 NOTES...

Страница 16: ...anty applies only to products installed in the United States and Canada EXCLUSIONS This warranty does not cover any 1 Shipping labor or material charges 2 Damages resulting from transportation install...

Отзывы: