5292157-UIM-B-0317
16
Johnson Controls Unitary Products
SECTION XIII: UNIT DATA
TABLE 5:
Physical and Electrical Data - Cooling Only
Models
AVV25B
AVV37B
AVV37C AVV38B AVV38C
AVV49C
AVV49D
AVV50C
AVV50D
AVV61C
AVV61D
Blower-Diameter x Width
10 x 8
10 x 8
11 x 10
TBD
11 x 10
11 x 10
11 x 10
11 x 10
11 x 10
11 x 10
11 x 10
Motor
HP
1/2 HP
1/2 HP
1/2 HP
TBD
1/2 HP
3/4 HP
3/4 HP
3/4 HP
3/4 HP
3/4 HP
3/4 HP
Nominal RPM
1050
1050
1050
TBD
1050
1050
1050
1050
1050
1050
1050
Voltage
208/230
208/230
208/230
TBD
208/230
208/230
208/230
208/230
208/230
208/230
208/230
Full Load Amps @230V
4.5
4.5
4.5
TBD
4.5
7.0
7.0
7.0
7.0
7.0
7.0
Filter
1
Type
DISPOSABLE OR PERMANENT
Size
16 x 20 x 1 16 x 20 x 1 20 x 20 x 1
TBD
20 x 20 x 1 20 x 20 x 1 22 x 20 x 1 20 x 20 x 1 22 x 20 x 1 20 x 20 x 1 22 x 20 x 1
Permanent Type
Kit
1PF0601 1PF0601 1PF0602
TBD
1PF0602 1PF0602 1PF0603
1PF0602
1PF0603 1PF0602 1PF0603
Shipping / Operating
Weight (lbs.)
119/113
119/113
120/114
TBD
158/150
158/150
163/153
175/165
180/170
175/165
180/170
NOTES:
1. Field supplied.
TABLE 6:
Electrical Data - Cooling Only
Models
Motor FLA
1
Minimum Circuit Ampacity
MOP
2
208V
230V
208V
230V
25B / 37B / 37C / 38B / 38C
5.0
4.5
6.3
5.6
15
49C / 49D / 50C / 50D / 61C / 61D
7.3
7.0
9.1
8.8
15
NOTES:
1. FLA = Full Load Amps.
2. MOP = Maximum Overcurrent Protection device; must be HACR type circuit breaker or time delay fuse. Refer to the latest edition of the National Electric Code or in
Canada the Canadian electrical Code and local codes to determine correct wire sizing.
TABLE 7:
Electrical Heat: Minimum Fan Speed
Heater Kit
Models
1,2,3
Nom. kW
@240V
Air Handler Models
AVV25B
AVV37B
AVV37C AVV38B AVV38C
AVV49C
AVV49D
AVV50D
AVV50D
AVV61C AVV61D
6HK(0,1)6500206
2.4kW Med Lo (D)Med Lo (D)Med Lo (D)
TBD
Med Lo (D) Med Lo (D)Med Lo (D) Med Lo (D) Med Lo (D)Med Lo (D)Med Lo (D)
6HK(0,1)6500506
4.8kW Med Lo (D)Med Lo (D) Med (C)
TBD
Med (C) Med Lo (D)Med Lo (D) Med Lo (D) Med Lo (D)Med Lo (D)Med Lo (D)
6HK(0,1)6500806
7.7kW Med Lo (D)Med Lo (D) Med Hi (B)
TBD
Med Hi (B) Med Lo (D)Med Lo (D) Med Lo (D) Med Lo (D)Med Lo (D)Med Lo (D)
6HK(0,1)6501006
6HK36501025
9.6kW Med Lo (D)Med Lo (D) Med Hi (B)
TBD
Med Hi (B) Med Lo (D)Med Lo (D) Med Lo (D) Med Lo (D)Med Lo (D)Med Lo (D)
6HK(1,2)6501306 12.5kW
Med (C)
Med (C) Med Hi (B)
TBD
Med Hi (B) Med Lo (D)Med Lo (D) Med Lo (D) Med Lo (D)Med Lo (D)Med Lo (D)
6HK(1,2)6501506
6HK36501525
14.4kW
-
Med Hi (B) Med Hi (B)
TBD
Med Hi (B)
Med (C)
Med (C)
Med (C)
Med (C) Med Lo (D)Med Lo (D)
6HK(1,2)6501806
6HK36501825
17.3kW
-
Med Hi (B) Med Hi (B)
TBD
Med Hi (B)
Med (C) Med Hi (B) Med (C)
Med Hi (B) Med (C)
Med (C)
6HK(1,2)6502006
6HK46502025
19.2kW
-
Med Hi (B)
Hi (A)
TBD
Hi (A)
Med Hi (B)
Hi (A)
Med Hi (B)
Hi (A)
Med Hi (B) Med Hi (B)
6HK(1,2)6502506
6HK46502525
24kW
-
-
-
TBD
-
-
Hi (A)
-
Hi (A)
-
Med Hi (B)
N
OTES:
1. (0,1) - 0 = no service disconnect OR 1 = with service disconnect.
2. (1,2) - 1 = with service disconnect, no breaker jumper bar OR 2 = with service disconnect & breaker jumper bar.
3. 6HK3 = 3-Phase with terminal block connectors only, 6HK4 = 3-Phase with service disconnect.