6. Programming first transmitter

7. Changing motors direction

4

1. Longer than 10 seconds pause between series of button clicks during programming will cause device to switch off from 

programming mode without saving any changes.

IV MODE - IMPULSE SWITCH

a) A short circuit between wires 1 and 3 causes to move the curtain in step-by-step mode.

METHOD 1:

Programming the first transmitter by this method it is possible, when none of the transmitters has been programmed.

METHOD 1:

Changing the work motor direction using this method is only possible before the limit positions are programmed.

METHOD 2: 

If the limit positions have not been set, programming the first transmitter removes the previously programmed transmitters from 

memory.

IV MODE 

has been set.

Press and hold the programming button 

on the motor for 10 seconds. Release 

programming button after the third flash

of the diode. Motor will make 3 sounds.

Press P2 

programming button

 4 times.

LED diode will flash 4 times. 

Motor will make 4 sounds.

Press and hold the programming

button on the motor for 2 seconds. 

The LED diode will flash 5 times. 

Motor will make 3 sounds.

Turn on 

the power.

When power is on press and hold 

programming button for 2 seconds.

Simultaneously

press and hold

UP and DOWN buttons

for 2 seconds.

LED diode will flash 5 times. 

Motor will make few 

short sounds.

LED diode flash once. 

Motor will make a sound.

Press and hold STOP button for 

2 seconds on the transmitter.

LED diode flashed. 

Motor will make a sound.

Press and hold STOP button for 

2 seconds on the transmitter.

LED diode will flash 5 times. 

Motor will make few sounds.

LED diode will flash 5 times. 

Motor will make few sounds.

The transmitter has been 

programmed.

The transmitter has been 

programmed.

The work motor direction

has been changed.

Содержание Ortino DT72TE Series

Страница 1: ...ill be installed and provide information to users about the conditions and maintenance of the device Failure to follow these instructions can present risk to life and health or invalid functioning of...

Страница 2: ...r should be performed by specialists with 1kV or higher SEP certi ed electrician s licence SEP Association of Polish Electrical Engineers or equal license Device is designed to operate in places shiel...

Страница 3: ...e Motor will make 3 sounds Press P2 programming button LED diode flash once Motor will make a sound I MODE has been set II MODE has been set III MODE has been set Press and hold the programming button...

Страница 4: ...on on the motor for 10 seconds Release programming button after the third flash of the diode Motor will make 3 sounds Press P2 programming button 4 times LED diode will flash 4 times Motor will make 4...

Страница 5: ...g button on the motor for 10 seconds Release programming button after the third flash of the diode Motor will make 3 sounds Press DOWN button LED diode will flash 5 times Motor will make a sound Addin...

Страница 6: ...position LED diode will flash 5 times Motor will make a few short sounds The limit position of the open curtain has been set Press and hold simultaneously DOWN and STOP buttons for 2 seconds Press and...

Страница 7: ...conds Release programming button after the third flash of the diode Motor will make 3 sounds Press programming button P2 on the remote control LED diode flash once Motor will make a sound Press UP but...

Страница 8: ...lash 7 times Motor will make 4 sounds Press programming button P2 on the remote control LED diode flash once Motor will make a sound Press DOWN button Press DOWN button LED diode will flash 5 times Mo...

Отзывы: