5. Connecting and configurating of the switch
3
1. Connect the switch to the socket using the RJ-9 plug. For mounting the RJ plug, use the right tools for it.
2. The motor can work in one of four switch modes:
I MODE - ASTABLE SWITCH FOR BLINDS:
a) A short circuit between wires 1 and 3 causes open or close the curtain.
b) A short circuit between wires 1 and 4 closes or stops the curtain.
II MODE - STABLE SWITCH FOR BLINDS:
a) A circuit between wires 1 and 3 causes open the curtain.
b) A circuit between wires 1 and 4 closes the curtain.
III MODE - ASTABLE SWITCH:
a) A short circuit between wires 1 and 3 causes open the curtain.
b) A short circuit between wires 1 and 4 closes the curtain.
c) A short circuit between wires 1,3 and 4 stops the curtain.
Press and hold the programming
button on the motor for 10
seconds. Release programming
button after the third flash
of the diode. Motor will make 3 sounds.
Press P2
programming button.
LED diode flash once.
Motor will make a sound.
I MODE
has been set.
II MODE
has been set.
III MODE
has been set.
Press and hold the programming
button on the motor for 2 seconds.
The LED diode will flash 5 times.
Motor will make 3 sounds.
Press and hold the programming
button on the motor for 10 seconds.
Release programming button after
the third flash of the diode.
Motor will make 3 sounds.
Press P2
programming button
2 times.
LED diode will flash 2 times.
Motor will make 2 sounds.
Press and hold the programming
button on the motor for 2 seconds.
The LED diode will flash 5 times.
Motor will make 3 sounds.
Press and hold the programming
button on the motor for 10 seconds.
Release programming button after
the third flash of the diode.
Motor will make 3 sounds.
Press P2
programming button
3 times.
LED diode will flash 3 times.
Motor will make 3 sounds.
Press and hold the programming
button on the motor for 2 seconds.
The LED diode will flash 5 times.
Motor will make 3 sounds.
4
3
2
1
close
open
common wire
1