1-4

IM 01B04N01-02E

1.3  Notice

This Instruction Manual

•  This manual should be passed on to the end user.  Keep at least one extra copy of the 

manual in a safe place.

•  Read this manual carefully to gain a thorough understanding of how to operate this 

product before you start using it.

•  This manual is intended to describe the functions of this product.  Yokogawa Electric 

Corporation (hereinafter simply referred to as Yokogawa) does not guarantee that these 

functions are suited to the particular purpose of the user.

•  Under absolutely no circumstances may the contents of this manual, in part or in whole, 

be transcribed or copied without permission.

•  The contents of this manual are subject to change without prior notice.

•  Every effort has been made to ensure accuracy in the preparation of this manual.  Should 

any errors or omissions come to your attention however, please contact your nearest 

Yokogawa representative or sales office.

Protection, Safety, and Prohibition against Unauthorized Modification

•  The following safety symbols are used on the product and in this manual.

Markings

If this symbol is indicated on the product, the operator should refer 

to the explanation given in the instruction manual in order to avoid 

personal injury or death to either themselves or other personnel, and/

or damage to the instrument.  The manual describes that the operator 

should exercise special care to avoid shock or other dangers that may 

result in injury or loss of life.

Protective ground terminal:

This symbol indicates that the terminal must be connected to ground 

prior to operating the equipment.

Function ground terminal:

This symbol indicates that the terminal must be connected to ground 

prior to operating the equipment.

AC voltage:

This symbol indicates that AC voltage is present.

DC voltage:

This symbol indicates that DC voltage is present.

•  In order to protect the product and the system controlled by it against damage and ensure 

its safe use, make certain that all of the instructions and precautions relating to safety 

contained in this document are strictly adhered to.  Yokogawa does not guarantee safety 

if products are not handled according to these instructions. 

•  If protection/safety circuits are to be used for the product or the system controlled by it, 

they should be externally installed on the product.

•  Do not turn off the power of the product during adjustment and parameter setting.

•  Be sure to confirm the parameters referring to ‘‘5.4 Parameter List’’ before installing the 

product in a system or plant. After confirming them, install the product in a system or plant 

and turn on the power.

•  When you replace the parts or consumables of the product, only use those specified by 

Yokogawa.

•  If the product is to be used in systems with special requirements for human safety, such 

in as nuclear power and radiation related equipment, railway facilities, aircraft facilities, 

and medical devices, please consult with your sales representative.

•  Do not modify the product.

Force Majeure

•  Yokogawa does not make any warranties regarding the product except those mentioned 

in the WARRANTY that is provided separately.

•  Yokogawa assumes no liability to any party for any loss or damage, direct or indirect, 

caused by the use or any unpredictable defect of the product.

Содержание YS80 Series

Страница 1: ...User s Manual Y okogawa Electric Corporation IM 01B04N01 02E 10th Edition Model SISD Style S Isolator...

Страница 2: ......

Страница 3: ...1 Names of Components 5 2 5 2 Setting Jumper 5 3 5 2 1 Check of Setting Jumper and Its Position 5 3 5 3 Setting of Parameters 5 4 5 3 1 Configuration of Parameters 5 5 5 3 2 Description of Parameters...

Страница 4: ...Blank...

Страница 5: ...g of the controller Maintenance of equipment Related Documents The following documents all relate to the SISD Isolator Read them as necessary Manual Title Manual No Description Rack Mounted Instrument...

Страница 6: ...nsure that the product is as specified in the order F0101 ai 100 120VAC 50 60Hz ISOLATOR SISD 100 S XXXXXXXXX 1 5VDC 100mA 7 0VA 24 110VDC 100 120VAC 50 60Hz ISOLATOR SISD 100 S XXXXXXXXX 1 5VDC 100mA...

Страница 7: ...o complement the present topic and or describe terms specific to this document Gives reference locations for further information on the topic Description of Displays Some of the representations of pro...

Страница 8: ...must be connected to ground prior to operating the equipment Function ground terminal This symbol indicates that the terminal must be connected to ground prior to operating the equipment AC voltage Th...

Страница 9: ...mA DC signals which are isolated from the input signal and the power supply With the VJ77 Parameter Setting Tool you can do the following Read write all parameters at once Save read parameters to a f...

Страница 10: ...2 2 IM 01B04N01 02E 2 1 Standard Specifications Please see the General Specifications GS 01B04N01 02E at the end of this manual...

Страница 11: ...d Style Code S Style S Option Codes 1 2 NHR FBP LOCK WSW REK TB A2TB A2ER Without rack case Power supply fuse bypass Power supply plug with lock With spring washer Mount to same line with EK series ra...

Страница 12: ...Blank...

Страница 13: ...tallation 1 2 3 App 1 2 3 5 6 7 8 4 Installation For details of the installation procedure and wiring precautions refer to the instruction manual Installation of Rack Mounted Instruments IM 1B4F2 01E...

Страница 14: ...C B A 8 7 6 5 4 3 2 1 OUT IN Terminal arrangement Figure 3 1 Terminal Layout Table 3 1 Terminal Wiring Terminal Designation Description A Output1 1 to 5 V DC B C D F Output2 4 to 20 mA DC H J K Do not...

Страница 15: ...etc in micro processor to be Pulse Width Modulation PWM then is converted into 1 to 5 V DC or 4 to 20 mA DC signals in output circuit through optical isolation circuit Output Circuit Input Processing...

Страница 16: ...Blank...

Страница 17: ...hen inserting the internal unit into the rack case firmly connect the multi pin connectors for connecting the internal unit and the case 3 Make sure that power plugs are properly connected to the powe...

Страница 18: ...Name plate Output terminal block Main board Terminal cover and handle for drawing out the internal unit Two pole plug with earthing contact Multi pin connector Input terminal block Rack case F0501 ai...

Страница 19: ...he internal unit out from the rack case b Check that the jumper on the main board of the internal unit is set to obtain the desired action c Use the tweezers to change the position of jumper d Put the...

Страница 20: ...munication cable of 5 pin connector type model F9182EE and the adapter for modularjack model E9786WH are required For details of operation and adjusting procedures of VJ77 Parameters Setting Tool refe...

Страница 21: ...low cut point is shown in the figure below A 0 2 hysteresis is used for the low cut point Y X Output Signal Y Input Signal X Low cut point Hysteresis fixed to 0 2 0 3 D33 OUT1 DR and D34 OUT2 DR Sets...

Страница 22: ...AG NO 2 Tag Number2 Up to 8 single byte Alphanumeric D03 COMMENT1 Comment1 Up to 8 single byte Alphanumeric D04 COMMENT2 Comment2 Up to 8 single byte Alphanumeric D17 LINEARIZE1 Linearize OFF SQR OFF...

Страница 23: ...6 1 IM 01B04N01 02E Maintenance 1 2 3 App 1 2 3 5 6 7 8 4 Maintenance This chapter describes the calibration procedures that can be done in the instrument room or service shop Chapter 6 Maintenance...

Страница 24: ...following test equipment manufactured by Yokogawa or their equivalent DC Voltage Current Standard Yokogawa GS200 or the equivalent 1 set Digital Voltmeter Yokogawa DM7560 or the equivalent 1 set PC V...

Страница 25: ...dy Terminal for adjustment The procedure is shown below using the JHT200 Handy Terminal as an example Adjust SISD using JHT200 Handy Terminal a Connect the equipment as illustrated in Figure 6 1 b Set...

Страница 26: ...put value and the in put display of P04 SPAN ADJ1 If the input value does not correspond to the display value select P04 SPAN ADJ1 to enter the adjustment mode Mainly select INC addi tion or DEC subtr...

Страница 27: ...use S9510VK Approx 3 years If the fuse breaks or if the replacement period elapses please have the item replaced Power supply unit L3510YA Standard L3510YF Option codes TB FBP or REK L3510YT Option co...

Страница 28: ...Blank...

Страница 29: ...7 1 IM 01B04N01 02E Troubleshooting 1 2 3 App 1 2 3 5 6 7 8 4 Troubleshooting If any fault occurs in the instrument note the symptoms and follow Section 7 1 Chapter 7 Troubleshooting...

Страница 30: ...OM error 0002 ERROR EEPROM SUM ERROR Output 0 or less Communication Undefined Parameter error 1000 ERROR AD ERROR Output 0 or less Communication Normal action A D conversion error 0008 ERROR INPUT OVE...

Страница 31: ...ecify the terminal block to which the power source is directly connected option codes TB A2TB and REK the external wiring to the terminal block is necessary therefore drawing out the internal unit req...

Страница 32: ...nal Block Output Terminal Cover Power Fuse Power Terminal Cover Input Terminal Cover Power Terminal Input Terminal Block Power and Ground Terminal connection Connection screw M4 Symbol L N Description...

Страница 33: ...S C3307 Vinyle sheathed cables for electric appliances KIV stranded wires conforming to JIS C3316 Note Power supply cables should be determined from the instrument power consumption they must have con...

Страница 34: ...Blank...

Страница 35: ...AND APPEARANCE Mounting Rack mounting Wiring Signal Wiring ISO M4 size 4mm screws on terminal block Power and Ground Wiring 100 V version JIS C 8303 two pin plug with earthing contact IEC A5 15 UL458...

Страница 36: ...less above sea level Warm up time 15 minutes or more after the power is turned on n TRANSPORT AND STORAGE CONDITIONS Temperature 25 to 70 C Temperature change rate 20 C per hour or less Humidity 5 to...

Страница 37: ...eral tolerance value of tolerance class IT18 based on JIS B 0401 2016 2 Cable length 300 mm Power supply terminal type option TB or A2TB F02 ai 136 22 71 300 52 48 180 L N Trigonometry Unit mm General...

Страница 38: ...r supply terminal type option REK F03 ai 52 71 300 32 136 48 200 190 5 L N 2 7 Trigonometry Unit mm General tolerance value of tolerance class IT18 based on JIS B 0401 2016 2 Power supply terminal blo...

Страница 39: ...yle S Option Codes 1 2 NHR FBP LOCK WSW REK TB A2TB A2ER Without rack case Power supply fuse bypass Power supply plug with lock With spring washer Mount to same line with EK series rack With power sup...

Страница 40: ......

Страница 41: ...May 2004 Change of the company name 9th Edition Oct 2019 Change of the style number 10th Edition Jan 2021 VJ77 parameter setting tool R3 01 or later support n Written by Yokogawa Electric Corporation...

Страница 42: ...4th Floor 129090 Moscow RUSSIA Phone 7 495 737 7868 Fax 7 495 737 7869 YOKOGAWA CHINA CO LTD 3F Tower D Cartelo Crocodile Building No 568 West Tianshan Road Shanghai 200335 CHINA Phone 86 21 62396262...

Отзывы: