background image

7

 

 

<Read Me First>

IM 01W02D02-11EN

n

  Cautions for Safely Applying the Device

l

  EMC Conformity Standards

EN 61326-1 Class A, Table 2, EN 55011 Class A, Group 1, EN 61000-6-2
This instrument is a Class A product, and it is designed for use in the industrial environment.
Please use this instrument in the industrial environment only.

l

  Safety Conformity Standards

Applicable standard: EN 61010-1, EN 60825-1, CSA-C22.2 No. 61010-1

(1) Pollution Degree 2

 

“Pollution degree” describes the degree to which a solid, liquid, or gas which deteriorates 

dielectric strength or surface resistivity is adhering. “2” applies to normal indoor atmosphere. 

Normally, only non-conductive pollution occurs. Occasionally, however, temporary 

conductivity caused by condensation must be expected.

(2) Overvoltage category I

 

“Overvoltage category (Installation category)” describes a number which defines a transient 

overvoltage condition. It implies the regulation for impulse withstand voltage. “I” applies 

to electrical equipment which is supplied from the circuit when appropriate transient 

overvoltage control means (interface) are provided.

(3) Indoor/Outdoor use

 

It can be used in indoors and outdoors.

(4) Altitude of installation site

 

Max. 3,000 m above sea level

n

  About Laser

YFGW610-C is compliant with class 1 laser in accordance with EN 60825-1:2014 and  

CDRH 21-CFR 1040.

CAUTION

•  To avoid eye injury although, please do not see a light source.

n

 W

iring the Ground

Appropriate grounding is necessary for the stable operation of YFGW610.
The frame ground (FG) terminal (M4 screw) is located on the side of power supply connector on 

the top side of the mainbody.  
To connect the ground cable to the FG terminal, use a ring tongue terminal for M4 with an 
insulation sleeve.
Secure the M4 screws at a tightening torque of 1.2 to 1.5 Nm.

SEE 

ALSO

For grounding of YFGW610, see “B4.3 Grounding” of the YFGW610 user’s manual (IM 01W02D02-01EN). 

Содержание YFGW610

Страница 1: ...ormation to use this product correctly and safely for YFGW610 Field Wireless Media Converter Before use the product be sure to read this document first Contents Introduction 2 Safety Precautions 3 Exp...

Страница 2: ...entification tag attached on packing box are essential parts of the product keep them in a safe place for future reference l The purpose of the User s Manual is to describe details of functions provid...

Страница 3: ...a hazardous state All repairs and modifications of the product must be consulted with Yokogawa l If any protection or safety circuit is required for the system controlled by the product or for the pro...

Страница 4: ...product can be safely operated Please pay special attention to the following points a Installation This instrument may only be installed by an engineer or technician who has an expert knowledge of th...

Страница 5: ...strument by the customer g Product Disposal The instrument should be disposed of in accordance with local and national legislation regulations h Authorized Representative in EEA The Authorized Represe...

Страница 6: ...rranty and Disclaimer l Yokogawa assumes no responsibilities for this product except as stated in the warranty l Yokogawa shall have neither liability nor responsibility to any person or entity with r...

Страница 7: ...ber which defines a transient overvoltage condition It implies the regulation for impulse withstand voltage I applies to electrical equipment which is supplied from the circuit when appropriate transi...

Страница 8: ...caused by Electronic Information Products in the People s Republic of China RoHS Pb Hg Cd Cr VI PBB PBDE YFGW610 GB T26572 GB T26572 SJ T11364 l EU RoHS This product is in conformity with the followin...

Страница 9: ...cations For Explosion Protected Types Item Description Code Factory Mutual FM Nonincendive Approval 1 ATEX Type n declaration 2 Applicable Standard EN IEC 60079 0 EN 60079 15 II 3 G Ex nA IIC T4 Gc X...

Страница 10: ...ated outside the range Power Dissipation 10 W Altitude Up to 3000 m Enclosure The equipment shall be installed in an enclosure that provides a minimum ingress protection of IP54 in accordance with EN...

Страница 11: ...the type of protection and installation practices relevant rules and regulations and general principles of area classification The degree of protection not less than IP54 shall be maintained at cable...

Страница 12: ...Plate Main Name plate MODEL Specified model code SUFFIX Specified suffix code STYLE Style code SUPPLY Specified Voltage Range and wattage S N Serial number and year of production 1 YOKOGAWA TOKYO 180...

Страница 13: ...egistered trademarks in this User s Manual Patent Notice n Notice NO RIGHTS OR LICENSES EXPRESS OR IMPLIED ARE GRANTED TO USE THIRD PARTY DEVICES IN COMBINATION WITH THESE PRODUCTS IN A WIRELESS MESH...

Страница 14: ...t Delete Expired issue year of ATEX Applicable Standard EN 60079 0 2009 3rd Edition March 2017 2 5 9 10 11 13 14 Update Introduction Update Safe Use of This Product Add RoHS description Update ATEX Ty...

Отзывы: