background image

4

 

 

<Read Me First>

IM 01W02D02-11EN

NOTE

Draws attention to information essential for understanding the operation and features.

TIP

Indicates additional information.

SEE 

ALSO

Indicates a source to refer to

  Indicates a protective grounding terminal. Before using the product, ground the terminal.

  Indicates a functional grounding terminal. Before using the product, ground the terminal.

  Indicates a DC supply

n

 S

afe Use of This Product

This product is designed to be used by a person with specialized knowledge. For the safety of the operator 

and to protect this product and the system, please be sure to follow this manual’s safety instructions when 

handling this product. If these instructions are not heeded, the protection provided by this product may be 

impaired. In this case, Yokogawa cannot guarantee that this product can be safely operated. Please pay 

special attention to the following points:

(a)  Installation

•  This instrument may only be installed by an engineer or technician who has an expert 

knowledge of this device. Operators are not allowed to carry out installation unless they 

meet this condition.

•  All installation shall comply with local installation requirements and the local electrical code.

(b)  Wiring

•  The instrument must be installed by an engineer or technician who has an expert 

knowledge of this instrument. Operators are not permitted to carry out wiring unless they 

meet this condition. All installation shall comply with local installation requirements and the 

local electrical code.

(c)  Operation

CAUTION

When ambient temperature is beyond 50°C, a temperature of the surface is very high. Please be 

careful not to touch with bare hands. 

(d)  Maintenance

•  Please carry out only the maintenance procedures described in this manual. If you require 

further assistance, please contact the nearest Yokogawa office.

Содержание YFGW610

Страница 1: ...ormation to use this product correctly and safely for YFGW610 Field Wireless Media Converter Before use the product be sure to read this document first Contents Introduction 2 Safety Precautions 3 Exp...

Страница 2: ...entification tag attached on packing box are essential parts of the product keep them in a safe place for future reference l The purpose of the User s Manual is to describe details of functions provid...

Страница 3: ...a hazardous state All repairs and modifications of the product must be consulted with Yokogawa l If any protection or safety circuit is required for the system controlled by the product or for the pro...

Страница 4: ...product can be safely operated Please pay special attention to the following points a Installation This instrument may only be installed by an engineer or technician who has an expert knowledge of th...

Страница 5: ...strument by the customer g Product Disposal The instrument should be disposed of in accordance with local and national legislation regulations h Authorized Representative in EEA The Authorized Represe...

Страница 6: ...rranty and Disclaimer l Yokogawa assumes no responsibilities for this product except as stated in the warranty l Yokogawa shall have neither liability nor responsibility to any person or entity with r...

Страница 7: ...ber which defines a transient overvoltage condition It implies the regulation for impulse withstand voltage I applies to electrical equipment which is supplied from the circuit when appropriate transi...

Страница 8: ...caused by Electronic Information Products in the People s Republic of China RoHS Pb Hg Cd Cr VI PBB PBDE YFGW610 GB T26572 GB T26572 SJ T11364 l EU RoHS This product is in conformity with the followin...

Страница 9: ...cations For Explosion Protected Types Item Description Code Factory Mutual FM Nonincendive Approval 1 ATEX Type n declaration 2 Applicable Standard EN IEC 60079 0 EN 60079 15 II 3 G Ex nA IIC T4 Gc X...

Страница 10: ...ated outside the range Power Dissipation 10 W Altitude Up to 3000 m Enclosure The equipment shall be installed in an enclosure that provides a minimum ingress protection of IP54 in accordance with EN...

Страница 11: ...the type of protection and installation practices relevant rules and regulations and general principles of area classification The degree of protection not less than IP54 shall be maintained at cable...

Страница 12: ...Plate Main Name plate MODEL Specified model code SUFFIX Specified suffix code STYLE Style code SUPPLY Specified Voltage Range and wattage S N Serial number and year of production 1 YOKOGAWA TOKYO 180...

Страница 13: ...egistered trademarks in this User s Manual Patent Notice n Notice NO RIGHTS OR LICENSES EXPRESS OR IMPLIED ARE GRANTED TO USE THIRD PARTY DEVICES IN COMBINATION WITH THESE PRODUCTS IN A WIRELESS MESH...

Страница 14: ...t Delete Expired issue year of ATEX Applicable Standard EN 60079 0 2009 3rd Edition March 2017 2 5 9 10 11 13 14 Update Introduction Update Safe Use of This Product Add RoHS description Update ATEX Ty...