1.1  Using This Instrument Safely

(1)   Maintenance

WARNING

•   Maintenance of the vortex flowmeter should be performed by trained personnel with 

knowledge of safety. No operator shall be permitted to perform any operations relating to 

maintenance.

•   Do not open the cover in wet weather or humid environments. When the cover is opened, the 

stated enclosure protection is not applicable.

•   For details on maintenance, read the maintenance manual in the related documents indicated 

in Table 1.1. Perform only maintenance that is described in this manual. Do not perform other 

maintenance. If other maintenance is necessary, contact your nearest sales office or Service 

Center.

•   When opening and closing the cover, pay sufficient care to handling of screws and O-rings to 

prevent damage and attachment of foreign objects.

•   Some of the electronic components used on this product are susceptible to damage as a 

result of static electricity. Take sufficient care when handling electronic components by, for 

example, wearing wrist straps to prevent charging by static electricity and not directly touching 

electronic components, circuits and other components susceptible to static electricity.

(2)   Modification

Yokogawa will not be liable for malfunctions or damage resulting from any modification made to 

this instrument by the customer.

(3)   Product Disposal

The instrument should be disposed of in accordance with local and national legislation/

regulations.

(4)   Authorized Representative in EEA

In relation to the CE Marking, The authorized representative for this product in the EEA 

(European Economic Area) is: Yokogawa Europe B.V. Euroweg 2,

3825 HD Amersfoort, The Netherlands

(5)   CE Marking

CE marking is displayed on the nameplate for non-explosion protected type devices and ATEX 

explosion protected type devices. Products with CE marking are in compliance with the statutory 

requirements of the applicable EU directives.

*VY150 with nickel alloy CW-12MW body material is not compliant with PED, so the CE marking is not displayed.

(6)   EU RoHS Directive

EN IEC 63000:2018

(7)   Morocco Conformity Mark 

This conformity mark indicates that the product complies with Moroccan requirements.

Содержание VY Series

Страница 1: ...User s Manual Vortex Flowmeter VY Series Maintenance Manual IM 01F07A01 02EN IM 01F07A01 02EN 1st Edition...

Страница 2: ...rage Precautions 8 3 MAINTENANCE 9 3 1 Changing the Orientation of the Transmitter Case and Sensor Terminal Box 9 3 2 Removing and Rotating the Indicator 10 3 3 Removing the Amplifier Unit 12 3 4 Inst...

Страница 3: ...those for the standard type under the specified model number break down and do not cover custom made instruments Please note that this manual may not be revised for any specification changes construc...

Страница 4: ...follows Functional ground terminal Direct current Handling precaution This is attached to locations where this manual must be referenced to protect personnel safety and devices When handling this ins...

Страница 5: ...in accordance with local and national legislation regulations Table 1 1 Related Documents Document title Document No Vortex Flowmeter VY Series GS 01F07A00 01EN FSA130 Magnetic Flowmeter Vortex Flowm...

Страница 6: ...ctronic components by for example wearing wrist straps to prevent charging by static electricity and not directly touching electronic components circuits and other components susceptible to static ele...

Страница 7: ...resulting from handling operation or storage that violates the intended use and specifications Problems that result from using or performing maintenance on the instrument in a location that does not c...

Страница 8: ...ected thoroughly before it is shipped from the factory When this instrument is delivered to the installation site check its external appearance for damage and make sure that all parts for installation...

Страница 9: ...ould be as follows The preferred ambient temperature and humidity levels are 25 C and approximately 65 RH Ambient temperature 40 to 85 C Humidity 0 to 100 RH no condensation 3 When storing a vortex fl...

Страница 10: ...ormed at the Yokogawa factory The orientation of the transmitter case and sensor terminal box can be changed in 90 degree increments four directions Follow the procedure below to change the orientatio...

Страница 11: ...nd adhesion of foreign matter Replace O rings if they are damaged or deformed If there is no lubricant on the O rings apply silicone based grease CAUTION In the case of an explosion protected type ins...

Страница 12: ...htening the screws and washers 6 When installing the indicator perform the removal procedure in reverse to return the parts to their original positions then tighten the indicator mounting screws The i...

Страница 13: ...oreign matter Replace O rings if they are damaged or deformed If there is no lubricant on the O rings apply silicone based grease Follow the procedure below to remove the amplifier unit 1 Turn the pow...

Страница 14: ...amplifier unit mounting guide pins into the mounting holes 3 Lightly press the upper and lower parts of the amplifier unit simultaneously to insert the amplifier unit into the transmitter case Take c...

Страница 15: ...ent make sure that no explosive atmosphere conditions are present Before removing the shedder bar stop the flow and remove any remaining fluid When removing or installing the shedder bar pay careful a...

Страница 16: ...tention to the sensor cable 3 Remove the shedder bar mounting bolts 2 to 10 bolts and washers then remove the shedder bar fixing block and shedder bar with attention to the sensor cable The instrument...

Страница 17: ...Table 3 2 Partially tighten each bolt equally 3 to 4 times until the tightening torque value is reached Read Figure 3 8 for the bolt tightening sequence F1105 ai Upstream Number of bolts 2 Number of...

Страница 18: ...49 3 74 3 49 3 VY150 0 VY200 1 69 98 69 VY200 0 69 98 69 VY250 0 157 210 140 VY300 0 157 210 140 VY400 0 160 240 140 1 For SPG stainless steel gasket plated with silver only 2 For ASME JPI Class 150...

Страница 19: ...e Flow velocity V V N 1 t 1 KT UKT 4 D2 f Reynolds number Re Re V D f 1 1000 N Number of input pulses pulse t Time corresponding to N sec f Instrument error correction coefficient e Compressible fluid...

Страница 20: ...low rate Uk Uk m3 For M mass Uk f U f Uk kg d For user specified units Uk Uk User 3 Mass flow rate calculation for instruments with built in temperature sensor and analog input a Steam In the case of...

Страница 21: ...2 T1 T2 2 T2 T1 2 10 2 a2 k1 1 T2 k2 1 T1 T1 2 T2 T2 2 T1 10 6 kx 1 a1 Tx 10 2 a2 Tx 2 10 6 Tx Tx Tn x 1 2 M Mass flow rate Qn Volumetric flow rate at normal conditions Qf Volumetric flow rate at ope...

Страница 22: ...21 IM 01F07A01 02EN Revision Information Title Vortex Flowmeter VY Series Maintenance Manual Edition Date Page Revised Item 1st Feb 2022 New publication...

Отзывы: