6-2
<Toc> <Ind>
<6. Display Specification >
All Rights Reserved Copyright © 2006, Yokogawa Electric Corporation
IM 01C25R51-01E
(2)
DTM Works Menu Structure (Example of HART)
F0601E.EPS
F0601E.EPS
Connect
Disconnect
------
Parameter
Additional functions
------
Show and Compare parameters...
------
Upload from device
Download to device
------
Print
------
Property
Online Parameter
Offline Parameter
EJXMVTool Help
EJXMVTool About
Initialize
Report
Export XMV
Diag/Service
Observer
Flow Configuration Wizard
Obtain Flow Coefficient
------
About
------
Refresh online Data
Import XMV
Import PRM
(HART only)
Online Parameter
Offline Parameter
Diag/Service
Observe
Figure 6.1 Menu structure
(3)
Data Flow Diagram
Transmitter (EJX910A)
Online
Parameterization
Transmitter
General Parameters
Online Parameterization *
Sensor
Sensor Input
(DP,SP,ET)
Simulated Sensor Input
(DP,SP,ET)
Obtain Flow
Coefficient Module
(
Simulation Mode
)
INPUT
OFC *
Process Value
(DP,SP,ET)
Flow Coefficient
(Flow, Density, Viscosity, Gas
Expansion Factor, Discharge
Coefficient, Reynolds No.)
Obtain Flow
Coefficient Module
OFC
*
Offline Database
Offline
Parameterization
Transmitter
General Parameters
Flow Configuration
Wizard
PRM file
Report File (CSV)
initialize
Xmv file
Transmitter
General
Parameters
dfs file
Compatible between different frame applications
Compatible between HART and FFDTMs
Not compatible between different frame applications
User Flow
Parameters
(note2)
Transmitter
Flow
Parameters
Flow
Configuration
DownloadD
o
w
n
lo
a
d
to Device *to
D
e
v
ic
e
*
Uplo
ad from
U
p
lo
a
d
f
ro
m
De
v
ic
e *
D
e
v
ic
e
*
Transmitter
Flow
Parameters
User Flow
Parameters
Open
/Save
as
User Flow
Parameters(csv)
Import
User Flow
Parameters
Transmitter Flow
Parameters
Open
/Sav
e as
Transmitter General
Parameters
Not compatible between HART and FF DTMs
HART
Transmitter
General
Parameters
Transmitter Flow Parameters
FCW start
up
Apply
Enter
Start Up
Transmitter General
Parameters
Transmitter Flow
Parameters
(note1)
OFC
*
Expor
t
F0602E.EPS
Import/Export
Im
p
o
rt/
E
x
p
o
rt
Import/Export
Impor
t/Expor
t
Im
p
o
rt/
E
x
p
o
rt
Impor
t/Expor
t
Load
from /
Save t
o
Download
to Device *
Uplo
ad from
De
v
ic
e *
* : Online function (executed while connected)
(note1) EJXMVTool calculates Transmitter Flow Parameters
based on the User Flow Parameters. A transmitter
does not hold User Flow Parameters.
(note2) User Flow Parameters consist of primary element
information, fluid information, and operating condition.
(note3) Generated by FSA210.
Can be imported to HART DTM.
(note3)
Figure 6.2 Data flow diagram