<3. Function Specification>

All Rights Reserved Copyright © 2006, Yokogawa Electric Corporation

IM 01C25R51-01E

3.5.4

Primary Devices Supported in Auto Compensation Mode

This function is supported by EJXMVTool DTM.

Table 3.3 Supported primary devices

T0302E.EPS

Fixed Mode (Sets the discharge coefficient and gas expansion factor to a fixed value)

Primary Device

Orifice Flange Taps [ASME MFC-3M 1989]

Orifice Flange Taps [AGA No.3 1992]

Orifice Flange Taps [ISO5167-2 2003]

Orifice D and D/2 Taps [ISO5167-2 2003]

Orifice D and D/2 Taps [ASME MFC-3M 1989]

Orifice D and D/2 Taps [ISO5167-1 1991]

Orifice Corner Taps [ISO5167-2 2003]

Orifice Flange Taps [ISO5167-1 1991]

Orifice Corner Taps [ISO5167-1 1991]

Orifice Corner Taps [ASME MFC-3M 1989]

ASME FLOW NOZZLES [ASME MFC-3M 1989]

Classical Venturi tube with a machined convergent section [ISO5167-1 1991/ ISO5167-4 2003]

ISA1932 nozzle [ISO5167-1 1991/ ISO5167-3 2003]

ASME Venturi Tubes With a machined convergent section [ASME MFC-3M 1989]

Classical Venturi tube with a rough-welded sheet-iron convergent section 
[ISO5167-1 1991/ ISO5167-4 2003]

ASME Venturi Tubes With a rough Cast or Fabricated Convergent [ASME MFC-3M 1989]

Long radius nozzle [ISO5167-1 1991/ ISO5167-3 2003]

Classical Venturi tube “as cast” convergent section [ISO5167-1 1991/ ISO5167-4 2003]

Venturi nozzle [ISO5167-1 1991/ ISO5167-3 2003]

Orifice

Type

FIX

Nozzle

Venturi

Содержание vigilantplant EJXMVTool FSA120

Страница 1: ...User s Manual Y okogawa Electric Corporation IM 01C25R51 01E FSA120 EJXMVToolTM EJX MV Configuration DTM IM 01C25R51 01E 4th Edition...

Страница 2: ...ns 1 5 1 2 7 DIPPR 1 5 2 General 2 1 3 Functional Specification 3 1 3 1 PC 3 1 3 1 1 Hardware Operating Environment 3 1 3 1 2 Software Operating Environment 3 1 3 2 Field Communication 3 2 3 3 Model t...

Страница 3: ...nications Manager 4 16 4 5 5 Connect the EJX910A to the power supply 4 16 4 5 6 Connect the NI FBUS card to the EJX910A 4 16 4 6 Start FDT frame application 4 17 4 6 1 Update DTM Browser 4 17 4 6 2 St...

Страница 4: ...Fluid Operating Range Setup 6 28 6 3 6 Fluid Physical Property Setup 6 31 6 3 7 Apply Flow Configuration 6 33 6 4 Flow ConfigurationWizard Basic Mode 6 33 6 4 1 Flow Configuration Mode 6 33 6 4 2 Basi...

Страница 5: ...Blank Page...

Страница 6: ...nd user The information contained in this manual is subject to change without prior notice The information contained in this manual in whole or part shall not be transcribed or copied withoutYOKOGAWA...

Страница 7: ...trademark of Intel Corporation IBM PC AT is a registered trademark of International Business Machines Corp HART is a registered trademark of HART Communication Foundation MACTek is a registered tradem...

Страница 8: ...essing operations Use of the Licensed Software for any purpose other than those as ex pressly specified in the documentation provided by Licensor shall be prohibited Any result or damage arising out o...

Страница 9: ...RE LICENSOR AND SUPPLIERS DISCLAIM ANY AND ALL LIABILITY AND WILL HAVE NO LIABILITY FOR VIOLA TION MISAPPROPRIATION OR INFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS OF ANY THIRD PARTY 2 IN NO EVENT SHA...

Страница 10: ...ems it is not reasonable to license without such void or unen forceable part Licensor is entitled to modify the terms of this Agreement or terminate this Agreement at its option without owing any liab...

Страница 11: ...Blank Page...

Страница 12: ...lculation of flow parameters for EJX910 Database EJX MV Configuration DTM Dialog editor Fluid information Notebook PC FF H1 HART Communications Frame Application Comm DTM Flow Parameter Management Sen...

Страница 13: ...Blank Page...

Страница 14: ...er with an administrative authority Microsoft Windows XP Professional SP2 English Following software is necessary to be installed in your computer Common Adobe Reader FDT Frame application conforming...

Страница 15: ...Files FJX910 HART DTM included inYokogawa DTM Library HART FJX910 FF DTM included inYokogawa DTM Library FF IMPORTANT If you already have FSA210 Mass Flow Configuration Software installed in your comp...

Страница 16: ...am and HART DTMs of other YOKOGAWA products Yokogawa DTM Library FF Includes EJX910 FF DTM EJXMVTool source program and FF DTMs of other YOKOGAWA products Yokogawa MVTool additional resource disk Prog...

Страница 17: ...VTool Flow Configuration Wizard Obtain Flow Coefficient Database Table 3 2 Function of EJXMVTool for FF communication T0301 2E EPS Program Function Startup method Entry of License Contens Install loca...

Страница 18: ...ess value monitoring Tag Range Unit Damping Lowcut Indicator display Maintenance Adjustment Status information display 2 Offline Parameter The Transmitter General parameters of the device can be edite...

Страница 19: ...low operation and density compensation are performed conventionally with the flow factors being input manually Refer to section 6 4 3 File management xmv file Import export User Flow parameters Import...

Страница 20: ...67 1 1991 Orifice Corner Taps ISO5167 2 2003 Orifice Flange Taps ISO5167 1 1991 Orifice Corner Taps ISO5167 1 1991 Orifice Corner Taps ASME MFC 3M 1989 ASME FLOW NOZZLES ASME MFC 3M 1989 Classical Ven...

Страница 21: ...e 1 Decene Carbon Monoxide Methyl Vinyl ether 1 Decanal Carbon Tetrachloride Monochlorobenzene 1 Decanol Chlorine n Butane 1 Dodecene Chlorodifluoromethane n Butanol 1 Dodecanol Chloroprene n Butyrald...

Страница 22: ...Association for the Properties of Water and Steam 3 Density compensation using standard Natural gas AGA8 Compressibility Factors of Natural Gas and Other Related Hydrocarbon Gases American Gas Associa...

Страница 23: ...Blank Page...

Страница 24: ...choose Start Control Panel PowerOptions to open Power Options Properties dialog box Confirm the settings on this dialog box are the same as follows Power Schemes Tab System standby and System hibernat...

Страница 25: ...ab Hibernate Tab Do not check the option Enable hibernation Apply F0403E EPS Hibernate Advanced Power Schemes Power Options Properties Cancel OK UPS Disk space for hibernation Hibernate When you compu...

Страница 26: ...lick the filename in Windows Explorer FieldInstDrive is the drive on which field communication server is installed FieldInstDrive is the drive where the PRM directory is located The default drive is t...

Страница 27: ...ing the previous version of FieldMate Advance If the version is equivalent or higher install Additional Resource Disk alone if you have purchased FSA120 with FieldMate Advance check the version of Fie...

Страница 28: ...l resource installation Execute CDROM Resource setup exe Double click the file name in Windows Explorer and the EJXMVTool installation program will be started CDROM is the CD ROM drive of your compute...

Страница 29: ...ight 2006 Yokogawa Electric Corporation IM 01C25R51 01E 3 Input User Name Organization and Click Next F0407E EPS Figure 4 6c Customer Information Screen 4 Select Complete or Custom Complete setup is r...

Страница 30: ...Preparation All Rights Reserved Copyright 2006 Yokogawa Electric Corporation IM 01C25R51 01E 5 Click Install F0409E EPS Figure 4 6e Ready to install screen 6 Click Finish F0410E EPS Figure 4 6f Finish...

Страница 31: ...F0411E EPS Version number Figure 4 7 Version Number of DTM Library 2 EJXMVTool DTM The version number is displayed on the HELP screen of Flow Configuration Wizard or Obtain Flow Coefficient Refer to 6...

Страница 32: ...01E 4 3 Uninstallation 1 FieldMate Refer to User s manual IM01R01A01 00E 2 MVTool Additional Resouce Use the Add or Remove Programs function of the Windows Control Panel Select Yokogawa MVTool additi...

Страница 33: ...RT Communication Modem Connect the HART communication modem to the PC s COM port NOTE Either a serial RS232C or USB port may be used 4 4 2 COM port Find out which COM port the modem will be connected...

Страница 34: ...ration All Rights Reserved Copyright 2006 Yokogawa Electric Corporation IM 01C25R51 01E F0415E EPS Figure 4 10b Hardware propoerties Click Ports COM LPT to find out the port number F0416E EPS Figure 4...

Страница 35: ...4 4 Communication setting HART communication This subsection describes the procedures to change the communication related setting of FieldMate Please try these procedures after you start FieldMate an...

Страница 36: ...lue 1 Click the Tool HART Modem Configuration at FieldMate window 2 Select address number 3 Click the OK button F0435E EPS Maximum value of communication Addressfor scaning Figure 4 14 Address Setting...

Страница 37: ...tivate the program as an Administrator or user with an Administrative authority 1 Activate the program On PC click the following order and activate the program Click Start All Programs National Instru...

Страница 38: ...4 15c NI FBUS H1 Port Properties 1 Device Address Select Visitor Device Type Select Basic Device Usage Select NI FBUS CAUTION Do not set the NI FBUS card to Link Master Device in the Fieldbus segment...

Страница 39: ...15e Starting NI FBUS IMPORTANT When running the program log in the Windows as an Administrator or an user with an administrative authority 4 5 5 Connect the EJX910A to the power supply Please refer to...

Страница 40: ...plication This section describes the operation of DTM with using FieldMate For the detailed operation of FieldMate refer to User s manual of FieldMate IMPORTANT When running the program log in the Win...

Страница 41: ...eldMate Starting FieldMate by following operation 1 Click Start All Programs YOKOGAWA FieldMate FieldMate F0424E EPS Figure 4 17a Start FieldMate 2 Default Scan Segment is to select the communication...

Страница 42: ...nect to FieldMate If not No device found message is shown on the window If a connected device icon does not appear check that initial setting for communication is correctly done Refer to section 4 4 f...

Страница 43: ...Electric Corporation IM 01C25R51 01E F0428 03E EPS Figure 4 17e Version Number of EJX910 DTM 4 6 3 Start EJX910 DTM 1 Start DTM Works Select the icon of the target device for configuration in the win...

Страница 44: ...ter snapshot is saved to an external file dfs file which includes the following parameters User Flow parameters Transmitter Flow parameters Transmitter General parameters For a file format of dfs refe...

Страница 45: ...by closing each window 1 Click the File Exit at DTM Works window 2 Click the File Exit at FieldMate window 4 7 EJXMVTool Activation 4 7 1 How to Activate Start EJX910DTM see 4 6 3 Start DTM Works Sel...

Страница 46: ...ight 2006 Yokogawa Electric Corporation IM 01C25R51 01E F0431E EPS Figure 4 22 Software License Form Once the license number is confirmed Flow Configuration Wizard screen below appears F0432E EPS Figu...

Страница 47: ...Blank Page...

Страница 48: ...e Setup Fluid Physical Property Setup Export XMV menu Fluid type Setup Initialize menu Offline Parameter Flow Configuration Wizard Parameter Device Upload Transmitter Flow parameters and Transmitter G...

Страница 49: ...nline Parameter screen is opened Offline Parameter Disconnect Device Goes online Connect Device Open Offline Parameter window Parameter Device Load the XXXXXX dfs User Flow parameters Transmitter Flow...

Страница 50: ...Additional functions Device You can check th flow coefficient The value is saved in a log file FlowCoeffLog Download to device 2 Device Obtain Flow Coefficient Additional functions Disconnect Device D...

Страница 51: ...h flow coefficient The value is saved in a log file FlowCoeffLog Download to device 2 Device Obtain Flow Coefficient Additional functions Device FieldMate Menu DTM Works Menu Sub Menu Sub Menu Procedu...

Страница 52: ...r Online Parameter Obtain Flow Coefficient Export Report Initia lize Import Help Import PRM Export XMV Report Initialize Import XMV EJXMVTool Help EJXMVTool About Refer to section 6 1 Flow configurati...

Страница 53: ...rt File CSV initialize Xmv file Transmitter General Parameters dfs file Compatible between different frame applications Compatible between HART and FFDTMs Not compatible between different frame applic...

Страница 54: ...ion of EJX910 DTM Please refer to EJX910DTM HELP for detail Please also refer to FieldMate User s Manual for operation F0603E EPS Click here to refer EJX910DTM HELP for detail HART Click here to refer...

Страница 55: ...nd address are not shown on the online parameter screen Use Segment Viewer to confirm the PD Tag and address of the device NOTE Connect menu is active only while the transmitter is disconnected 2 How...

Страница 56: ...and stored in offline database Parameters saved in offline database can be downloaded to the device by using Download to Device function Parameters in the device can be uploaded to the offline databa...

Страница 57: ...All Rights Reserved Copyright 2006 Yokogawa Electric Corporation IM 01C25R51 01E 2 Offline Parameter Click the Device Parameter Offline Parameter F0606E EPS Figure 6 6a Go to Offline Parameter F0606 0...

Страница 58: ...EPS Figure 6 7 Upload from Device Offline Parameters Transmitter Flow Parameters Transmitter General Parameters are uploaded from the transmitter to offline database They can be edited using offline p...

Страница 59: ...2 Click the Device Download to Device FF DTM 1 Click the Device Parameter Offline Parameter 2 Check the checkbox of the function blocks downloading to a device F0608aE EPS Figure 6 8a Checkbox of Blo...

Страница 60: ...okogawa Electric Corporation IM 01C25R51 01E Downloading icon on the tool bar can also be used to execute download F0608bE EPS Figure 6 8b Download to Device NOTE Download to Device menu is active onl...

Страница 61: ...rameters can be printed out by using print function Click the Device Print Select Online Parameter Offline Parameter Diag Service Observe F0609E EPS Figure 6 9 Print 6 1 5 Properties The EJX910 DTM ve...

Страница 62: ...6 Additional functions 1 Diag Service for HART Diagnostics related parameters are shown Click the Device Additional Functions Diag Service F0611E EPS Figure 6 11a Diag Service 2 Observe for HART Proc...

Страница 63: ...Management can be done from the Flow Configuration Wizard by the following procedures Click the Device Additional Functions Flow Configuration Wizard F0613E EPS Figure 6 12Top Menu Screen of Flow Con...

Страница 64: ...PS Figure 6 13b Initializing Message 6 2 2 Import 1 Import Flow Configuration XMV file User Flow parameters and Transmitter Flow parameters can be imported NOTE Refer to 7 File Format for information...

Страница 65: ...ng R1 02 00 or earlier the following message is displayed F0615 02E EPS Figure 6 14b Information Message for Reference Pressure Reenter the absolute pressure equivalent to the displayed gauge pressure...

Страница 66: ...E EPS Figure 6 15 Exporting a File 6 2 4 Report Export user flow parameters in CSV File format NOTE Report can be used only in the Apply Flow Configuration screen F0617E EPS Figre 6 16 Report NOTE Use...

Страница 67: ...opyright 2006 Yokogawa Electric Corporation IM 01C25R51 01E 6 2 5 Help 1 EJXMVTool Help The EJXMVTool manual map opens when this menu is clicked F0618E EPS Figure 6 17 Help NOTE EJXMVTool Online Help...

Страница 68: ...in Flow Cefficient version number is shown when this menu is clicked F0619E EPS Figure 6 18 About The EJXMVTool DTM version number is also shown by Add or Remove Program of Windows Control Panel Refer...

Страница 69: ...uid physical properties and primary element for the EJX910 can be performed using a dialog window Basic Mode Flow operation and density compensation are performed conventionally with the flow factors...

Страница 70: ...d sheet iron convergent section ISO5167 1 1991 ISO5167 4 2003 ASME Venturi Tubes With a rough Cast or Fabricated Convergent ASME MFC 3M 1989 Long radius nozzle ISO5167 1 1991 ISO5167 3 2003 Classical...

Страница 71: ...ally calculated according to the material Table 6 3 Pipe material T0605E EPS Pipe Material Remarks 304 Stainless Steel Default 316 Stainless Steel Carbon Steel Hastelloy C Monel 6 3 3 Fluid Setup Auto...

Страница 72: ...m Gas DIPPR Gas Custom Data Table When Natural Gas Default is selected for Category select the Fluid name Method from the followings AGA8 Detail Characterization Method Default AGA8 Gross Characteriza...

Страница 73: ...achloride Monochlorobenzene 1 Decanol Chlorine n Butane 1 Dodecene Chlorodifluoromethane n Butanol 1 Dodecanol Chloroprene n Butyraldehyde 1 Heptanol Chlorotrifluoroethylene n Butyronitrile 1 Heptene...

Страница 74: ...ry Liquid Custom set the Fluid name Method in the blank box 6 3 4 Natural Gas Setup 1 AGA8 Detail Characterization F0623E EPS Figure 6 22 Natural Gas Setup Screen 1 Input the value as mole percent for...

Страница 75: ...tane mole percent 0 6 1 13 C5H12 i Pentane mole percent 0 4 2 14 C5H12 n Pentane mole percent 0 4 2 15 C6H14 n Hexane mole percent 0 Dew Point 3 16 C7H16 n Heptane mole percent 0 Dew Point 3 17 C8H18...

Страница 76: ...10 0 3 17 76 42 87 MJ m3 477 1150 BTU ft3 at 14 73 psi abs 60 F at 101 56 kPa abs and 15 56 F at 14 73 psi abs 60 F at 101 56 kPa abs and 15 56 F Expanded Range Remarks 3 AGA8 Gross Characterization...

Страница 77: ...as Setup Screen 4 Input the value as mole percent for each component shown in Table 6 9 The each value must be specified within the range shown in Table 6 9 Total mole percent must become 100 Standard...

Страница 78: ...C4H10 i Butane mole percent 0 1 5 1 12 C4H10 n Butane mole percent 0 1 5 1 13 C5H12 i Pentane mole percent 0 0 5 2 14 C5H12 n Pentane mole percent 0 0 5 2 15 C6H14 n Hexane mole percent 0 0 1 16 C7H16...

Страница 79: ...emarks 6 3 5 Fluid Operating Range Setup 1 Gas or Steam excluding Category Saturated steam F0628E EPS Figure 6 27 Fluid Operating Range Setup Screen 1 Input operating ranges and select units Pressure...

Страница 80: ...e configuration If the temperature and pressure range input on the Fluid Operating Range Setup is too wide there is a probability of the calculation error of density is big These ranges are used only...

Страница 81: ...value on the following page fluid physical property setup page and continue configuration If the pressure range input on the Fluid Operating Range Setup is too wide there is a probability of the calcu...

Страница 82: ...used only for the density and viscosity calculation Range of Transmitter are not changed 6 3 6 Fluid Physical Property Setup 1 Gas or Steam Natural gas ISO physical properties setup F0633E EPS Figure...

Страница 83: ...Operating Range Setup is narrow Please specify another value wider range and try again F0634E EPS Figure 6 33 Information message for setting range 2 Liquid F0635E EPS Figure 6 34 Fluid Physical Prope...

Страница 84: ...S Figure 6 35 Apply Flow Configuration In order to download the configuration to the transmitter please select Apply Then perform download store to device from your frame application Please refer to C...

Страница 85: ...flow factors being input manually NOTE 1 The flow unit is not automatically converted in basic mode 2 The flow range is set to LRV 0 and URV 100 when the Flow Configuration Mode is changed to Basic Mo...

Страница 86: ...calculated according to the Flow unit category 3 Reter to table 6 5 6 6 6 7 Qm or Qv_norm 1 Kfactor Flow unit Category 3 P T Tb SPb SP P 1 Temp K1 T Tb P Tb T SP SPb 2 b 2 b norm 2 b 2 b 1 K 2 b 1 K...

Страница 87: ...Electric Corporation IM 01C25R51 01E 2 Liquid F0639E EPS Figure 6 38 Basic Mode Setup for Liquid Input Reference Temperature Tb Kfactor Temp K1 Input Reference static pressure to 0 This factor is use...

Страница 88: ...tter please select Apply Then perform download store to device from your frame application Please also refer to Chapter 5 and Figure 6 2 6 5 Obtain Flow Coefficient Click the Device Additional Functio...

Страница 89: ...Blank Page...

Страница 90: ...rent frame application can access the file Compatible between both protocol DTM HART and FF WinInstDrive Desk Top My Documents Default HART General parameters file XXXXXX prm HART Transmitter General...

Страница 91: ...awa DTMs EJXMVTool Report File XXXXXX csv User flow parameters in CSV file format WinInstDrive Desk Top My Documents Default Physical property Error Log File 1 FF EJXMVToolFF log EJXMVToolFF1 log Back...

Страница 92: ...and sub code is shown in error log file EJXMVTool log 8 1 Error Message Table 8 1 Error message T0801E EPS Code Sub code Explanation Recovery Information Message 600 8 Rank deficient The temperature...

Страница 93: ...Blank Page...

Страница 94: ...ed to take the following three steps 1 Uninstall field communication server Execute FieldInstDrive PRM Program PRMUninstall exe Double click the filename in Windows Explorer FieldInstDrive is the driv...

Страница 95: ...FSA210 Uninstallation All Rights Reserved Copyright 2006 Yokogawa Electric Corporation IM 01C25R51 01E NOTE It takes a few seconds for the EXA Bossed service to stop FA0103E EPS Figure A1 3 Click OK F...

Страница 96: ...stall the EJXMVTool program with the Add or Remove Programs function of the Windows Control Panel Select EJXMVTool and click Change Remove FA0105E EPS Figure A1 5 3 Uninstall Exaopc Use the Add or Rem...

Страница 97: ...wa Electric Corporation IM 01C25R51 01E Click OK FA0107E EPS Figure A1 7 Click Yes FA0108E EPS Figure A1 8 Select Yes and click Finish This will reboot the computer FA0109E EPS Figure A1 9 NOTE After...

Страница 98: ...updating on Offline parameters screen in EJX910 FF DTM 6 13 6 2 2 Add Note for xmv file made in FSA120 R 102 00 or before 6 19 6 3 3 Correct the method name for steam 6 23 6 3 4 Correct the mole vali...

Отзывы: