10 - 5
IM 4H3B1-01E
1
0. GENERAL SPECIFICATIONS
Relation between Chart Speed and Intervals of Periodic Printout:
Pen Model
Dot Model
DISPLAY
Display Method:
VFD (5
×
7 dot matrix, 20 characters).
Digital Display:
AUTO
Channel No. or tag, type of alarm, measured values, unit (front 3
digits), for each channel alternately
MAN
Channel No. or tag, type of alarm, measured values, unit (front 3
digits), for one specific channel
CLOCK
Year / month / date and hour / min / sec will be displayed
VIEW
Status for IC Memory Card and TLOG function will be displayed
Bargraph Display:
Measured data
Left-centered (%) bargraph and center-zero bargraph
(selectable for each channel).
Alarm
Setting level of alarm, in case of alarm: flashing display.
Other Displays:
RCD:
recording in progress
POC:
Pen Offset Compensation (pen model only)
SET:
SET Mode
AUTO: Auto display is used
MAN: Manual display is used
CLK:
Clock display is used
ALM: shared alarm (not corresponding to any channel)
CHT:
Chart end indicator (optional)
BAT:
low battery
ALARM
Number of Levels:
Up to four levels for every channel (High, Low, Delta high, Delta low, High rate-of-
change, Low rate-of-change selectable)
Interval time of rate-of-change alarm is the measuring interval multiplied by 1 to 15
(selectable, and common for both rate-of-change alarms).
Display:
Set value:
Is indicated as a segment on the bargraph.
In case of alarm:
This segment will start flashing on the bargraph and the digital
display will show the type of alarm. The alarm indicator in
different display will show alarm.
Hysteresis:
Approx. 0.5% of recording span (only High, Low) and 0%, selectable (common for all
channels and all levels).
Chart Speed
Printing Interval of Periodic Printout
6 dot
12 dot
18 dot
24 dot
1 to 9 mm/h
no printout
no printout
no printout
no printout
10 to 19 mm/h
every 8 hrs.
every 12 hrs.
every 12 hrs.
every 24 hrs.
20 to 39 mm/h
every 4 hrs.
every 8 hrs.
every 8 hrs.
every 12 hrs.
40 to 50 mm/h
every 2 hrs.
every 4 hrs.
every 4 hrs.
every 8 hrs.
51 to 79 mm/h
every 2 hrs.
every 4 hrs.
no printout
no printout
80 to 100 mm/h
every hour
every 2 hrs.
no printout
no printout
101 to 1500 mm/h
no printout
no printout
no printout
no printout
Chart Speed
Printing Interval of Periodic Printout
5 to 9 mm/h
10 to 18 mm/h
20 to 36 mm/h
40 to 72 mm/h
75 to 135 mm/h
150 to 180 mm/h
200 to 320 mm/h
360 to 1500 mm/h
more than 1500 mm/h
no printout
every 8 hours
every 4 hours
every 2 hours
every hour
every 30 minutes
every 20 minutes
every 10 minutes