Transmitter
Quick Reference Instruction Manual
Wiring
IM01U10A00-00EN-R, 2nd edition, 2017-08-29
43 / 54
Active status
output
P/Sout
Since this is a transistor contact, maximum allowed current as well as polarity and level of
output voltage must be observed during wiring.
Value
Load resistance
> 1 kΩ
Internal power supply
24 V
DC
±20 %
P/Sout+
P/Sout-
24 V
0 V
1
ROTAMASS
Fig. 31:
Active status output connection
P/Sout
①
External device with load resistance
Active status output
P/Sout
with internal
pull-up resistor
Value
Internal pull-up resistor
2.2 kΩ
Internal power supply
24 V
DC
±20 %
1
P/Sout+
P/Sout-
24 V
0 V
ROTAMASS
Fig. 32:
Active status output
P/Sout
with internal pull-up resistor
①
External device