< 3. INSTALLATION, PIPING AND WIRING >
3-59
IM 12A0V2-E
L(101)
N(102)
G(001)
(201)L
(202)N
(002)G
(11)
(12)
(301)
(302)
Power
Converter
for chlorine
L
N
G
Power
Sensor
Sensor
(32)NC
(31)C
(33)NO
S1
(42)NC
(41)C
(43)NO
S2
(72)NC
(71)C
(73)NO
S4
(61)
+
(62)
-
mA1
(65)
+
(66)
-
mA2
(81)
+
(82)
-
mA3
(85)
+
(86)
-
mA4
(21)
(22)
(24)
SHLD(63)
(87)
+
(88)
-
SHLD(89)
A
+
(91)
B
-
(92)
GND(93)
SHLD(94)
Termination(95)
RS485(-R)
Ethernet(-E)
SENCOM
Disuse
L(101)
N(102)
G(001)
L(201)
N(202)
G(002)
(52)NC
(51)C
(53)NO
S3
BK
WH
RD
L
N
G
U1
U2
U3
S
Power
US
Oscillator
L(201)
N(202)
G(203)
L(
30
1)
N
(30
2)
G
(00
4)
L(101)
N(102)
G(001)
CP
AR
Terminal box for connecting solenoid valve
Contact output
(-WR)
Solenoid Valve
pH Sensor
Power
Supply
Terminal box for power supply
FC800D
Non-reagent Type Free Available Chlorine Sensor Unit
FLXA402T
Liquid Analyzer for Turbidity detector and
Chlorine sensor unit
Analog output
(-N2, -N4)
Analog output
(-N2, -N4)
Analog output
(-N4)
Analog output
(-N4)
Contact input
(-N2, -N4)
Analog input
(-N4)
PG400 Pulse Generator for Clean Unit
Flow-Through type holder
Figure 3.60
ST401G-PF8-N-A /AZC (/R) (/TT3) With free available chlorine analyzer and pH analyzer,
auto zero calibration, (back piping), (500 ml KCl tank)
ST401G-PF8-P-A /AZC (/R) (/TT3) With free available chlorine analyzer and pH analyzer,
ultrasonic oscillator, auto zero calibration, (back piping), (500 ml KCl tank)