Wiring
Quick Reference Instruction Manual for Spare
Transmitter replacement
IM01U10A01-00EN-R, 1
st
edition, 2019-12-09
63 / 76
Active status
output
P/Sout
Since this is a transistor contact, maximum allowed current as well as polarity and level of
output voltage must be observed during wiring.
Value
Load resistance
> 1 kΩ
Internal power supply
24 V
DC
±20 %
P/Sout+
P/Sout-
24 V
0 V
ROTAMASS
1
Fig. 40:
Active status output connection
P/Sout
①
External device with load resistance
Active status
output
P/Sout
with internal
pull-up resistor
Value
Internal pull-up resistor
2.2 kΩ
Internal power supply
24 V
DC
±20 %
P/Sout+
P/Sout-
24 V
0 V
ROTAMASS
1
Fig. 41:
Active status output
P/Sout
with internal pull-up resistor
①
External device
Passive status
output
P/Sout
or
Sout
Value
Output current
≤ 200 mA
Power supply
≤ 30 V
DC
P/Sout+ or Sout+
P/Sout- or Sout-
ROTAMASS
1
Fig. 42:
Passive status output connection
P/Sout
or
Sout
①
External device