3-6
IM 71M02D04-01E 10th Edition: 2012.12.01
3.4 Regenerative resistor Terminal <TB3>
List of Models Provided with Regenerative resistors
Model
Suffix code
Regenerative resistor
UM1LG3
-330
-
A-1
-N
80W 60
Ω
-530
-
A-1
-N
-240
-
A-1
-N
-330
-
A-2
-N
80W 200
Ω
-530
-
A-2
-N
-240
-
A-2
-N
If the motor is moved by external force, etc., additional large regenerative resistors will be
required, regardless of whether or not a regenerative resistor is supplied with the model.
When you replace attached regenerative resistors by the thing of other capacity, or when you
connect regenerative resistors to the drive to which regenerative resistor is not appended,
inquire at our sales department for more information.
Disconnect all power and wait 7 minutes, before servicing. Do not remove the separator
attached in the regenerative resistor terminal of a drive. May cause electric shock. The high
voltage is applied to the regenerative resistor terminal.
A regenerative resistor generates high temperatures. Do not touch the regenerative resistor
while operating the motor and the drive until the temperature has cooled down sufficiently.
!
DANGER
•
Make sure to connect the regeneration resistor supplied with the
product according to the figure.
See the list below for the models to which a regeneration resistor is
attached.
•
Use AWG#20 to AWG#16 to extend the cable.
Regenerative resistor
(attached)
CAUTION
!
DANGER
Connector: 231-202/206-00
(made by WAGO)