<1. GENERAL>
1-2
IM 11G02Q02-01EN 2nd Edition : Sep. 04, 2020-00
l
RS-485 Interface
Electrical specification :
Based on EIA RS-485
Transmission system :
2-wire, semi-duplicate
Synchronizing system :
Start-stop synchronous system
Connection format :
1*N
Maximum connectable units : 31 units
Transmission distance :
500 m max.(total extension distance)
Transmission speed :
38400 bps
Data format
Data length ;
8 bits
Stop bit ;
1 bit
Parity ;
None
X flow control ; None
Transmission code :
HEX value (MODBUS RTU mode)
Error detection :
CRC-16
Isolation :
Isolation from internal circuit
Functional isolation between signal line and ground