4. Configuration Setup
4-4
TI 30A10A30-01E
The Command Line Interface supports following functions.
Command input assistant function
Once enough letters are entered to uniquely identify a command name, press the “Tab” key to let
the system complete the rest of the command name.
Command/Parameters list choices display function
When a question mark “?” is entered, a list of possible command keywords or parameters is
displayed. By entering “?” as the parameter for a command, a list of the parameters available
and those descriptions are displayed. By entering “?” as the CLI prompt, a list of the commands
available and those descriptions are displayed.
Command history buffer function
Command lines that are executed in the past can be stored into the history buffer of the device.
These command lines can be reused.
• Entering “Ctrl”+“P”, go to previous line in history buffer.
• Entering “Ctrl”+“N”, go to next line in history buffer.
Up/Down cursor keys can be used instead of entering “Ctrl”+“P”/“N,” which is useful in repeating
a simple command set.
Text input function
A group of sequential commands can be input by using paste function of a text editor, which is
useful to set up the configuration by using a template text file prepared for a particular network
application.
The command entry buffer cannot accept too many command lines at a time.
For to use this function, set the transmit delay time to 1 msec/char on the serial port setup
window of the terminal software, and confirm if all the pasted commands are executed
completely.