How to Replace and Dispose the Batteries
EU Battery Directive 

(This directive is valid only in the EU.) Batteries are included in 

this product. 

When you remove batteries from this product and dispose them, 

discard  them  in  accordance  with  domestic  law  concerning 

disposal.

Take  a  right  action  on  waste  batteries,  because  the  collection 

system in the EU on waste batteries are regulated.

      Battery type: Manganese dry cell

Pb

      Criterion value (weight percent): Lead (Pb) 0.004%

Notice:

This  marking  indicates  they  shall  be  sorted  out  and  collected  as 

ordained in the EU battery directive.

The  chemical  symbol  beneath  the  marking  means  relevant 

chemical  substance  is  contained  more    than  criterion  value  in 

battery.

How to remove batteries safely: 

For further details, see "7 Battery Replacement". 

Authorized Representative in the EEA

Authorized Representative in the EEA Yokogawa Europe B.V. is 

the authorized representative of Yokogawa Test & Measurement 

Corporation for this product in the EEA.

(EEA: European Economic Area)

To  contact  Yokogawa  Europe  B.V.,  see  the  separate  list  of 

worldwide contacts, PIM 113-01Z2.

Содержание EY200

Страница 1: ...IM EY200 JA Japanese IM EY200 EN English 5th Edition Feb 2018 KYOU Store this manual in a safe place for future reference Model EY200 Digital Earth Tester User s Manual...

Страница 2: ...s one are provided as manuals for the EY200 Read them along with this manual IM EY200 EN This manual IM CROHS EY200 Document for China IM EY200 93Z2 Document for Korea Contact information of Yokogawa...

Страница 3: ...Check 31 5 2 Connecting Test Probes 31 6 Operating Instructions 31 6 1 Principle of Measurement 31 6 2 Precise Measurement 32 6 3 Simpli ed Measurement 33 7 Battery Replacement 36 8 Notes on Housing...

Страница 4: ...nt in contradiction to these cautionary notes WARNING Indicates a hazard that may result in the loss of life or serious injury of the user unless the described instruction is abided by CAUTION Indicat...

Страница 5: ...equipment etc CAT III For measurement preformed in the building installation Distribution board circuit breaker etc CAT IV For measurement preformed at the source of the low voltage installation Over...

Страница 6: ...ry compartment cover while making measurement Never attempt to make measurement if any abnormal conditions are noted such as broken case cracked test probe and exposed metal parts Never turn the range...

Страница 7: ...sure to let it dry before putting it in storage 2 Features Model EY200 is an earth resistance tester for testing power distribution lines in house wiring system electrical appliances etc It also has...

Страница 8: ...ea Electromagnetic Conformity Standard RF eld strength 1V m total accuracy speci ed accuracy RF eld strength 3V m total accuracy speci ed accuracy 5 of range Safety Standards EN 61010 1 EN 61010 2 030...

Страница 9: ...tem voltage Range to keep the maximum operating error Measurement range within which the maximum operating error 30 applies 20 range 5 to 19 99 200 range 20 to 199 9 2000 range 200 to 1999 Battery lif...

Страница 10: ...D mm Weight Approx 550g including batteries Accessories Product Name Model No Quantity Test Leads Red 20m Yellow 10m Green 5m 98074 1 set Auxiliary Earth Spikes 98070 2 2P Test Leads Red Black Green...

Страница 11: ...Mark Low Battery 3 Indication LED With Measurement 4 Press To Test Button MEASURE 5 Range Selector Switch 6 Measuring Terminals 7 Test Leads 8 Earth Spikes 9 2P Test Lead 10 Safety Alligator Clip 11...

Страница 12: ...nstrument will produce a maximum voltage of about 50V between terminals E C in earth resistance function Take enough caution to avoid electric shock hazard When measuring earth voltage do not apply vo...

Страница 13: ...e earthed equipment under test the yellow wire to the auxiliary earth spike P and the red wire to the auxiliary earth spike C from terminals E P and C of the instrument in order three pole wire method...

Страница 14: ...asurement the display reads Recheck the connection of test leads and the earth resistance of auxiliary earth spike CAUTION If measurement is made with the probes twisted or in touch with each other th...

Страница 15: ...ven in case of a live conductor when the connection of the earth electrode to be measured has come o or when the connection of the test leads of the instrument is not correct etc Do not use the instru...

Страница 16: ...n measurement LED remains illuminated during testing Turn the range switch to 200 and 20 when the earth resistance is low This indicated value is the earth resistance of the earthed equipment under te...

Страница 17: ...ment cover CAUTION Do not mix new and old batteries Install batteries in the orientation as shown inside the battery compartment observing correct polarity Six 6 1 5 V manganese batteries R6P AA size...

Страница 18: ...Case Lid Case lid can be fit under the housing case while making measurement 8 2 How to Fit Strap Belt The instrument is equipped with a Shoulder strap to suspend from the neck to allow both hands to...

Страница 19: ...e do not apply voltage greater than 200V between measuring terminals If the display reads in precise earth resistance measurement Stick the auxiliary earth spikes deeper into the earth or stick them a...

Страница 20: ...arking requirement This marking indicates that you must not discard this electrical electronic product in domestic household waste Product Category With reference to the equipment types in the WEEE di...

Страница 21: ...rcent Lead Pb 0 004 Notice This marking indicates they shall be sorted out and collected as ordained in the EU battery directive The chemical symbol beneath the marking means relevant chemical substan...

Страница 22: ......

Отзывы: