<7. General Specifications>
7-18
IM 01C25W01-01EN
1.4
Digital Remote Sensored Diaphragm Seal System
F40E.ai
Model
Suffix Codes
Description
EJXC40A
.............................................................
Digital remote sensored diaphragm seal system*
4
Measurement type
-D .....................................................
Differential Pressure
Master Style
(High pressure side)
5 ..................................................
Direct mount flanged diaphragm seal
6 ..................................................
Direct mount Hygienic diaphragm seal
S ..................................................
Screw mount*
1
Slave Style
(Low pressure side)
5 ..............................................
Direct mount flanged diaphragm seal
6 ..............................................
Direct mount Hygienic diaphragm seal
S ..............................................
Screw mount*
1
Digital Remote Sensor
R ..........................................
Digital Remote Sensor
Process Connection
for Master
W .....................................
With Flush type flanged seal
E ......................................
With Extended type flanged seal
T ......................................
With Screw monted
Wetted parts for Master
Master (High-side)
Diaphragm seal
□
..................................
Select from diaphragm material codes of diaphragm seal.
(Diaphragm material codes: S, V, H, J, T, U, M, or K)
Master (High-side)
Screw mounted
□
..................................
Select from GS 01C25W05-01EN (EJXC40A)
(Wetted parts material codes: L, or A)
Process Connection for Slave
W .............................
With Flush type flanged seal
E ..............................
With Extended type flanged seal
T ..............................
With Screw monted
Wetted parts for Slave
Slave (Low-side)
Diaphragm seal
□
..........................
Select from diaphragm material codes of diaphragm seal.
(Diaphragm material codes: S, V, H, J, T, U, M, or K)
Slave (Low-side)
Screw mounted
□
..........................
Select from GS 01C25W05-01EN (EJXC40A)
(Wetted parts material codes: L, or A)
Fill Fluid*
2
□
......................
Refer to table 3
Accessory for Master
-1 .................
With C10FR flushing connection ring
-N .................
None
Accessory for Slave
1 ..............
With C10FR flushing connection ring
N ..............
None
*1:
Applicable when screw mount is specified with either master or slave.
*2:
It must be selected fill fluid from diaphragm seal. When selecting screw mounted either master or slave, limits of
temperature is following table. and refer to GS 01C25W05-01EN (EJXC40A) for detail specifications.
Process temperature
Ambient temperature
Silicone
−40 to 120°C (−40 to 248°F)
−40 to 85°C (−40 to 185°F)*
3
Fluorinated oil (optional)
−40 to 120°C (−40 to 248°F)
−20 to 80°C (−4 to 176°F)
*3:
−30 to 80°C (−22 to 176°F) with LCD display
*4:
See subsection “Applicable Products” .
Option code /EC
(DRS cable) always must be specified.