6-5
IM DLM4038-03EN
Specifications
1
2
3
4
5
6
App
Index
Item
Specifications
Trigger type (A trigger)
Edge:
Triggers on the edge of a single trigger source
The source can be set to a signal from CH1 to CH8, LOGIC
1
, EXT, or LINE.
Edge OR:
Triggers when any of the edge trigger conditions of multiple trigger sources is met
Sources can be set to channels from CH1 to CH8.
Edge Qualified: Triggers on the edge of a single trigger source while qualifications are met
The source can be set to a signal from CH1 to CH8, LOGIC
1
, or EXT.
Qualifications can be specified for CH1 to CH8 and LOGIC
1
.
State:
Triggers when a pattern (conditions of signals) changes from met to not met or
from not met to met
A clock channel can be specified for determining whether the pattern has been
met or not met. No clock can also be selected.
Patterns can be combined using AND or OR.
The pattern signals and clock source can be set to a signal from CH1 to CH8 or
LOGIC
1
.
Pulse Width:
Triggers on the width of a single trigger source
The source can be set to a signal from CH1 to CH8 or LOGIC
1
.
More than:
Triggers when the time length during which the condition is met
is longer than Time1, and the condition changes to not met
Time1: 4 ns to 10 s in 2-ns steps
Less than:
Triggers when the time length during which the condition is met
is shorter than Time1, and the condition changes to not met
Time1: 6 ns to 10 s in 2-ns steps
Between:
Triggers when the time length during which the condition is met
is longer than Time1 but shorter than Time2 and the condition
changes to not met
Time1: 4 ns to (10 s – 4 ns) in 2-ns steps
Time2: 8 ns to 10 s in 2-ns steps
Minimum spacing between Time1 and Time2: 4 ns
OutOfRange:
Triggers when the time length during which the condition is met
is shorter than Time1 or longer than Time2 and the condition
changes to not met
Time1: 6 ns to (10 s – 4 ns) in 2-ns steps
Time2: 8 ns to 10 s in 2-ns steps
Minimum spacing between Time1 and Time2: 4 ns (2 ns only
when Time1 = 6 ns and Time2 = 8 ns)
TimeOut:
Triggers when the time length during which the condition is met
exceeds Time1
Time1: 4 ns to 10 s in 2-ns steps
Time accuracy:
2
±(0.5% of s 2 ns)
Minimum time
detection width:
2 ns (typical value
3
)
State Width:
Triggers on the time-duration for which a pattern (conditions of signals) is met or
not met
For details on the pattern signals and clock source and pattern combination, see
“State.”
For details on the time settings, see “Pulse Width.”
FlexRay:
4
Triggers on a FlexRay bus signal
The source can be set to a signal from CH1 to CH8.
Mode:
Frame Start, Error, ID/Data, ID OR
Bit Rate: 2.5 M, 5 M, 10 Mbps
Bus channel: A, B
CAN:
4
Triggers on a CAN (Controller Area Network) bus signal
The source can be set to a signal from CH1 to CH8.
Mode:
SOF, Error, ID/Data, ID OR
Bit Rate: 33.3 k, 83.3 k, 125 k, 250 k, 500 k, 1 Mbps, User Define
For User Define, you can set a value from 10 k to 1 Mbps in 0.1-kbps steps.
1 For LOGIC ports, L0 to L7, A0 to A7 and B0 to B7 bits can be set individually or at the port level.
A0 to A7 and B0 to B7 are available on models with the /L16 option.
2 Values measured under standard operating conditions (see section 6.11 for details) after a 30-minute warm-up.
3 Typical values represent typical or average values. They are not strictly warranted.
4 FlexRay and CAN are options.
6.2 Triggering Section