6
—Trigger function example—
•A to B(n) trigger
Example: Trigger on the 7th edge of signal on B. This is effective for
measurements with shifted timing, such as non-standard
video signal vertical/horizontal periods or motor reference
position pulses and drive pulses.
Input signal A
Input signal B
Trigger
•Serial pattern trigger (user defined)
Example: Trigger on an arbitrarily set pattern of up to 128 bits. This
is effective for detecting ID/Data and other portions of
proprietary communication formats.
Pattern configuration screen
Trigger
(Arbitrary pattern)
•Dual bus trigger
Example: Trigger on a combination of CAN and LIN bus triggers. I
2
C +
SPI bus triggers, and other combinations are possible.
Trigger when either LIN or CAN bus signal conditions become true
Input signal A CAN
Input signal B LIN
Real time filter with optimum noise reduction supports a wide range of frequencies
(from 8 kHz to 200 MHz)
The DLM2000 series has two types of filters, one processed at the input circuit and one based on MATH functions. These filters are effective
for rejecting unwanted signals, allowing observation of only the desired bandwidths.
Trigger Function capturing combined analog/digital complex waveforms
The DLM2000 series comes with a variety of easy-to-configure triggers combining analog and logic inputs such as edge, enhanced, and B triggers.
Real time filters
Each channel has 14 low pass filters available from 8 kHz to
200 MHz. Waveforms of limited bandwidths are stored in internal
memory.
Cutoff frequencies
: 200 MHz, 100 MHz, 20 MHz, 10 MHz, 5 MHz,
2 MHz, 1 MHz, 500 kHz, 250 kHz, 125 kHz,
62.5 kHz, 32 kHz, 16 kHz, and 8 kHz
Processing with built-in filters
Filtering of a PWM waveform using computation
Input signal
Computed
waveform
Computed digital filters
The input waveform can be filtered using an IIR filter, which is a
MATH function. Filtered waveforms can be displayed at the same
time as the input waveform for comparison. You can select low
pass or high pass filters.
Cutoff frequency setting range
: 0.01 Hz to 500 MHz
Edge trigger
Edge
Enhanced triggers
Edge OR
B triggers
A Delay B
A to B(n)
Dual bus
(combination trigger of 2 serial busses)
Edge
(qualified)
State
Pulse width
State width
Serial
(optional)
FlexRay/CAN/CAN FD/LIN/
SENT/PSI5/UART/I
2
C/SPI
(standard) user-defined
TV
NTSC/PAL/SDTV/
HDTV/user defined
unctionality
Large selection of triggers and filters
F