<10. EXPLOSION PROTECTED TYPE INSTRUMENT>
10-13
IM 01F06F00-01EN
10.5 TIIS
Certificate:
Model
Shedder
bar Material
Integral Type Flowmeter
Remote Type Detector
N (None Indicator)
D (With Indicator)
N (None Indicator)
DY015
DY025/R1
DY040/R2
E
TC14901
TC14912
TC14923
X
TC18903
TC18914
TC18925
DY025
DY040/R1
DY050/R2
E
TC19504
TC19513
TC19522
X
TC18904
TC18915
TC18926
DY040
DY050/R1
DY080/R2
E
TC19505
TC19514
TC19523
X
TC18905
TC18916
TC18927
DY050
DY080/R1
DY100/R2
E
TC19506
TC19515
TC19524
X
TC18906
TC18917
TC18928
DY080
DY100/R1
DY150/R2
E
TC19507
TC19516
TC19525
X
TC18907
TC18918
TC18929
DY100
DY150/R1
DY200/R2
E
TC19508
TC19517
TC19526
X
TC18908
TC18919
TC18930
DY150
DY200/R1
E
TC19509
TC19518
TC19527
X
TC18909
TC18920
TC18931
DY200
E
TC19510
TC19519
TC19528
X
TC18910
TC18921
TC18932
DY250
E
TC19511
TC19520
TC19529
DY300
E
TC19512
TC19521
TC19530
DY400
B
TC18945
TC18955
TC18965
Model
Shedder
bar Material
Remote Type Converter
N (None Indicator)
D (With Indicator)
DYA
TC14934
TC14935
Integral Type Flowmeter
Remote Type Flowmeter
None Indicator
With Indicator
Detector
Converter
Construction
Ex d IIC T6
←
←
←
Flame Proof Approval
←
←
←
Amb.Temp
-20°C up to +60°C
←
←
←
Rating
Maximum power supply vortage: DC42V
Current Signal: DC4-20mA
Pulse Signal:
ON : 2V 200mA
OFF : 42V 4mA
Output Voltage: 30Vp-p
Output Current: 100µ Ap-p
Maximum power supply vortage:
DC42V
Current Signal: DC4-20mA
Pulse Signal:
ON : 2V 200mA
OFF : 42V 4mA
Input Signal: 30V p-p,100µ A p-p
Resistance Temp, Sensor Input:
Pt1000 at 0°C
Specified Current: less than 1mA
* In case that ambient temperature exceeds 50°C, use heat-resistant cables with maximum allowable temperature of 70°C or above.