2.5  Others Functions

Wavelength Calibration (Details in chapter 3)

The built-in reference light source can be used to perform wavelength calibration of the instrument.

USB Mouse Operation (Details in chapter 3)

You can connect a USB mouse to perform the same operations that you can perform by tapping the 
instrument’s touch panel. Connect a USB mouse to a USB port on the instrument’s front panel.

User Keys (Details chapter 9 in IM AQ6370E-01EN)

Frequently used keys can be registered in the function menu (user keys).
By registering user keys, you can execute specific operations with less steps.
Up to 24 keys can be registered. By default, none of the keys are registered.

Application Feature (APP Feature) (Details chapter 8 in IM AQ6370E-01EN)

The application feature (APP feature) is an expansion feature used to install and uninstall various
dedicated software applications designed for this instrument. Various applications are available 
to assist with the measurement condition setup, analysis, and data saving according to the 
measurement target, such as DFB-LD, LED, and other light signals and WDM signals.
Add-on applications can be downloaded from YOKOGAWA webpage and installed to expand the 
features of the instrument.

Data Initialization (Details chapter 9 in IM AQ6370E-01EN)

Settings can be reset to their factory defaults.

Help (Details chapter 9 in IM AQ6370E-01EN)

Explanations of various settings, function menus, and keys can be shown on the instrument’s 
screen.

Key Lock (Details chapter 9 in IM AQ6370E-01EN)

Operation of keys other than the registered user keys can be locked to prevent operation mistakes 
by the user.

Remote (Details in IM AQ6370E-17EN)

This instrument can be remotely controlled over a network from a PC or other controllers.

Содержание AQ6370E

Страница 1: ...User s Manual AQ6370E Optical Spectrum Analyzer Getting Started Guide IM AQ6370E 02EN 1st Edition...

Страница 2: ...w us to serve you best by completing the user registration form accessible from our website https tmi yokogawa com support Contact Us If you want to resolve a technical support issue or need to contac...

Страница 3: ...actually appear on your screen Every effort has been made in the preparation of this manual to ensure the accuracy of its contents However should you have any questions or find any errors please cont...

Страница 4: ...nt for China Safety Instruction Manual IM 00C01C01 01Z1 A document for the EU Manuals Provided on the Website Download the following manuals from our website Manual Title Manual No Description AQ6370E...

Страница 5: ...Rated Voltage 250 V Q British standard Rated Voltage 250 V H Chinese standard Rated Voltage 250 V N Brazilian standard Rated Voltage 250 V T Taiwanese standard Rated Voltage 125 V B Indian standard R...

Страница 6: ...at the attached power cord meets the designated standards of the country and area that you are using it in If the suffix code is Y a power cord is not included UL CSA standard A1006WD VDE standard Kor...

Страница 7: ...ons In the manual the symbol is used in conjunction with the word WARNING or CAUTION WARNING Calls attention to actions or conditions that could cause serious or fatal injury to the user and precautio...

Страница 8: ...y for the customer s failure to comply with these requirements The following symbols are used on this instrument Handle with care Refer to the user s manual or service manual This symbol appears on da...

Страница 9: ...Connect the Protective Ground Terminal Be sure to connect the protective earth to prevent electric shock before turning ON the power The power cord that you can use for the instrument is a three pron...

Страница 10: ...specify them as accessories Do not use faulty accessories Install or Use the Instrument in Appropriate Locations Do not install or use the instrument outdoors or in locations subject to rain or water...

Страница 11: ...vant de mettre sous tension veiller brancher la mise la terre de protection afin d viter les chocs lectriques Le cordon d alimentation que vous utilisez pour l instrument est un cordon trois broches B...

Страница 12: ...e l instrument voir le sch ma fonctionnel l annexe 3 Ne pas appliquer de signaux de potentiel flottant la terre du connecteur d entr e Ceci est extr mement dangereux car le potentiel de terre risque d...

Страница 13: ...trument is a Class 1 laser product as defined by EN 60825 1 2014 A11 2021 IEC 60825 1 2007 Safety of Laser Products Part 1 Equipment Classification Requirements and User s Guide In addition this instr...

Страница 14: ...Regulation valid only in the EEA and UK Battery Regulation in the UK Batteries are included in this product This marking indicates they shall be sorted out and collected as ordained in the EU battery...

Страница 15: ...tment Wavelength Calibration Resolution Calibration Connecting the DUT Auto Sweep Setting and Measurement Other Settings Starting a Measurement Sweep Displaying Waveforms Displaying Calculated Wavefor...

Страница 16: ...4 2 4 Data Analysis 2 5 2 5 Others Functions 2 6 Chapter 3 Preparing for Measurement 3 1 Installing the Instrument 3 1 3 2 Attaching the Connector Adapter 3 6 3 3 Connecting the Device 3 9 3 4 Turning...

Страница 17: ...re 5 3 5 4 Mechanical Inspection 5 6 5 5 Operational Inspection 5 7 5 6 Replacing Fuses 5 8 5 7 Warning Display Function 5 9 5 8 Daily Maintenance 5 12 5 9 Care during Storage 5 14 5 10 Recommended Re...

Страница 18: ...Optical input connector For details on the usable optical fiber cables see section 3 9 POWER Used to start and shut down the instrument For details on the Power ON OFF see section 3 4 USB interface Us...

Страница 19: ...ls on the GP IB see chapter 2 in IM AQ6370E 17EN TRIGGER IN Trigger input For details on the trigger input see section 3 4 in IM AQ6370E 01EN ANALOG OUT Analog output For details on the analog output...

Страница 20: ...being measured The soft key functions change according to whether the screen display mode is wavelength display mode or frequency display mode LEVEL The LEVEL key contains functions related to level a...

Страница 21: ...al alignment wavelength adjustment hardware setup and setting initialization FILE Contains functions for saving and loading waveform data from the instrument s internal memory and USB storage memory A...

Страница 22: ...changes at the same time Note that if the COARSE key is on lamp on the numeric value increase decrease step will be larger Arrow keys Pressing the key has the same effect as turning the rotary knob c...

Страница 23: ...putting values with the numeric keypad The last entered right most character is removed allowing entry of the correct character By holding the BACK SPACE key down you can erase the entire entry in the...

Страница 24: ...h or center frequency Section 2 1 SPAN Displays and sets the sweep span Section 2 1 RES Displays and sets the resolution Section 2 2 SENS Displays and sets the sensitivity Section 2 4 AVG Displays and...

Страница 25: ...Subscale Displays relative levels of differential waveforms and normalized waveforms Section 2 6 21 Appears when Fiber Connector is set to Angled Section 3 8 22 Appears when High Close in Dynamic Mod...

Страница 26: ...Summary 1 2 3 4 5 6 App Index Chapter 2 Feature Summary 2 1 System Configuration DUT GP IB interface Ethernet interface USB mouse USB storage PC Video signal output 101 key USB keyboard USB mouse USB...

Страница 27: ...ilable By using the one action key functions you can set measurement conditions using the waveform data of the active trace trace set as the control or calculation target To use them a waveform must b...

Страница 28: ...l density display function which shows power per nm dB nm and a noise mask function which masks levels at or less than the specified value are available Horizontal Scale The horizontal scale of the wa...

Страница 29: ...her by setting up to 1024 fixed markers you can measure the wavelength difference or level difference between adjacent fixed markers and between the moving marker and a fixed marker In addition marker...

Страница 30: ...Optical power can be analyzed by integrating the measured waveform levels ITLA SSER STSSER Measurement Signal to Spontaneous Emission Ratio SSER and Signal to Total Source Spontaneous Emission Ratio S...

Страница 31: ...APP feature is an expansion feature used to install and uninstall various dedicated software applications designed for this instrument Various applications are available to assist with the measurement...

Страница 32: ...the instrument and use packaging with a shock absorbing capacity that is greater than or equal to the packaging used upon shipment from the factory Never use inferior packaging materials that are una...

Страница 33: ...ementales suffisamment longtemps avant de le retirer du carton Installation Conditions Install the instrument so that the following conditions are met Flat Horizontal Location Place the instrument in...

Страница 34: ...nt to adjust to the ambient temperature before use When the instrument is packaged in a box and moved prevent condensation by allowing sufficient time for the instrument to acclimatize before removing...

Страница 35: ...feet and handle attachment holes 5 Attach the rack mount kit to the instrument 6 Mount the instrument on a rack Note When rack mounting the instrument allow at least 10 cm of space around the inlet an...

Страница 36: ...nfirm that no other cables are connected before carrying the instrument Do Not Place Anything on Top of the Instrument Never stack instruments or place any other objects on top of the instrument espec...

Страница 37: ...to enter the monochromator adversely affecting its optical performance Also if debris is adhering to the optical components inside the monochromator when a strong light source is input the monochroma...

Страница 38: ...extr mit virole D placement de l adaptateur de connecteur vers la droite ou vers la gauche ou en l ins rant de force peut endommager la virole ou de l adaptateur de connecteur A connector adapter is r...

Страница 39: ...adapter s lock lever down The adapter has been attached correctly if the groove in the lock lever interlocks with the latch pin of the optical input output section Explanation Types of Connector Adap...

Страница 40: ...ns using the mouse see section 4 3 Connecting a Keyboard You can connect a keyboard for entering file names comments and other items Also the functions and settings of the instrument are assigned to k...

Страница 41: ...AUTION Do not remove the USB storage device or turn the power OFF while the USB storage device access indicator is blinking This can damage the data on the device or the device itself French ATTENTION...

Страница 42: ...ction will be compromised If there is no AC outlet that is compatible with the power cord that you will be using and you cannot ground the instrument do not use the instrument French AVERTISSEMENT Ass...

Страница 43: ...ed supply frequency range 48 Hz to 63 Hz Maximum power consumption Approx 100 VA This instrument can use a 100 V or a 200 V power supply The maximum rated voltage differs according to the type of powe...

Страница 44: ...and initialization of the instrument begins The instrument will not start for a few seconds immediately after step 2 even if you press the POWER switch The initialization screen appears and the intern...

Страница 45: ...ement a warm up of one hour is also required prior to measurement Unless the Wavelength Calibration is carried out the wavelength accuracy of the instrument cannot be guaranteed For details on wavelen...

Страница 46: ...MAIN POWER situ sur le panneau arri re Le fichier de configuration du syst me d exploitation ne serait pas sauvegard ce qui entra nerait probablement des dysfonctionnements la prochaine mise sous tens...

Страница 47: ...POWER switch for approximately four seconds or longer to force standby mode Note that the operating system configuration file will not be backed up possibly resulting in malfunctions upon start up the...

Страница 48: ...s le connecteur de sortie optique Ne regardez jamais directement dans le connecteur de sortie optique La lumi re infrarouge risquerait de gravement vous blesser ou de provoquer une perte de vision Pro...

Страница 49: ...ight source that you provide The external light source must meet the following conditions Wavelength range 1520 nm to 1560 nm 20 dBm or higher Level stability 0 1 dBp p or less Wavelength stability 0...

Страница 50: ...ent adjustment is executed The previous screen is displayed again after the alignment adjustment ends When the AQ6370E AQ6370D Reference Light Source Is Connected 3 Tap Built in Source 4 Tap Execute A...

Страница 51: ...perform internal wavelength calibration Perform wavelength calibration according to the instructions in Wavelength Calibration Using an External Light Source in section 3 7 Wavelength Calibration If y...

Страница 52: ...connecteur de sortie optique La lumi re infrarouge risquerait de gravement vous blesser ou de provoquer une perte de vision Procedure Wavelength Calibration Using the Internal Reference Light Source w...

Страница 53: ...finish If you are using this instrument for the first time or using it after it has been severely shaken while being moved you must perform the alignment adjustment procedure after warm up ends If th...

Страница 54: ...ler If the calibration light source level is less than or equal to 40 dBm Gas cell absorption line type When using a reference light source with multiple absorption lines if the instrument s wavelengt...

Страница 55: ...th value For Laser Type Light Sources 8 Tap the External Laser A screen for specifying the wavelength of the external light source is displayed 9 Select the laser wavelength value using the rotary kno...

Страница 56: ...l absorption line wavelength value using the rotary knob or the arrow keys The allowed wavelength range is 600 1700 nm 10 Press ENTER The wavelength value is set 11 Tap the Execute Wavelength calibrat...

Страница 57: ...6370E s optical input connector using a 9 5 125 m SM single mode optical fiber Light source Optical fiber AQ6370E Note For the light source use a stabilized single mode laser light Set the optical out...

Страница 58: ...lution is high e g 0 05 nm or less The resolution calibration function measures the equivalent noise bandwidth at each resolution setting and internally sets the resolution bandwidth to the result The...

Страница 59: ...SURED Peak value TRACE B waveform Measurement resolution used in the analysis algorithm e g EDFA NF If the RES BW parameter is set to MEASURED the resolution bandwidth is determined from the TRACE B w...

Страница 60: ...ting optical fiber Do not try to forcefully attach the optical fiber s optical connector with the plug inserted at a slanted angle Doing so may damage the instrument s optical connector s components o...

Страница 61: ...a lumi re d entr e v rifiez qu elle ne d passe la valeur nominale maximale de l analyseur AQ6370E car si tel tait le cas la section optique pourrait tre endommag e Appuyez fermement le connecteur opti...

Страница 62: ...e lap PC Otherwise set Normal Note If you set Fiber Connector to Angled is displayed in the measurement conditions area The instrument s measurement accuracy specification is for when Fiber Connector...

Страница 63: ...asurement level without improving resolution Optical fibers with a thick core diameter are especially useful for inputting spatial light for measurement but they have poor resolution Choose the best t...

Страница 64: ...e screen and sliding your finger This is used to move the displayed waveform or marker position Pinch Out and Pinch In Pinch out refers to the act of pressing two fingers against the screen and spread...

Страница 65: ...orizontally the zoom center wavelength center frequency the zoom start wavelength start frequency and the zoom stop wavelength stop frequency also change in sync Zooming a Waveform With the waveform d...

Страница 66: ...by dragging this line horizontally Moving marker You can move a line marker by dragging the line marker line Line markers Label Operation When you tap the label area a keyboard appears which you can...

Страница 67: ...For details on trace functions see chapter 4 in IM AQ6370E 01EN Trace setting area Select the trace you want to activate Select the trace operation mode Shows and hides traces Measurement Condition O...

Страница 68: ...eference level DIV value or the like on the main scale or the offset value or the like on the sub scale a parameter input window or parameter selection window appears which you can use to set the para...

Страница 69: ...ey Operation When you tap a shortcut key at the bottom of the waveform display area the function assigned to the key will be executed For a description of each shortcut key see section 1 4 Shortcut ke...

Страница 70: ...ecute its function immediately Contains a submenu Indicates that there is a submenu of additional items related to the current item Tap to display the submenu A separate window will be displayed Tap t...

Страница 71: ...nction that closes the window For example when the More 1 2 menu is taped the menu changes to the Setup 2 2 menu and the menu display changes to More 2 2 Shows the submenu of the function menu In this...

Страница 72: ...u Click the in the upper right of the screen The names of the front panel keys in the instrument s FUNCTION section are displayed You can also do the same by right clicking the mouse FUNCTION SWEEP CE...

Страница 73: ...etc Display settings TRACE SHIFT F6 Sets trace ZOOM SHIFT F7 Sets display scale DISPLAY SHIFT F8 Sets screen display Analysis functions MARKER SHIFT F9 Sets marker SEARCH SHIFT F10 PEAK BOTTOM search...

Страница 74: ...ost entered character in the numeric keypad input area is removed allowing entry of the correct character Note If the value entered with the numeric keypad is not in the allowed value range the neares...

Страница 75: ...value tap backspace to delete numbers from the right and enter the correct numbers 3 After entering a value tap nm ENT depending on the parameter unit The value is applied 4 Tap to close the parameter...

Страница 76: ...sition in the character input area where you want to input characters to move the cursor to that position You can also use the function menu to move the cursor insert characters delete all characters...

Страница 77: ...Entering the Date and Time 4 Tap the value you want to set The cursor moves to the value you tapped and a parameter input window appears The cursor position also moves by tapping Cursor on the functi...

Страница 78: ...rum matches the wavelength of the light source is within the wavelength accuracy standard For more information see section 6 2 Spectrum Width Measurement in IM AQ6370E 01EN 2 If the wavelength error i...

Страница 79: ...eform 10 Remove the SM optical fiber from the instrument and connect the light source to an optical power meter 11 Use the optical power meter to measure power values of the light source 12 Check that...

Страница 80: ...irmware The AQ6370E can read the update firmware UPD extension in one of two ways Prepare the update firmware according to your environment Reading the Firmware from a USB Memory Device Create a direc...

Страница 81: ...pdating is complete the AQ6370E automatically shuts down This completes the update procedure Turn the power on and the AQ6370E will start normally Note Once updating starts you cannot abort the proces...

Страница 82: ...AQ6370E over a network You need to enter a user name and password when establishing a connection User name user Password yokogawa 6 Use a file management software on the PC to copy the update software...

Страница 83: ...inspection mettre l instrument hors tension en pla ant l interrupteur MAIN POWER sur OFF sur le panneau arri re puis d brancher le cordon d alimentation ATTENTION Si des corps trangers se retrouvent...

Страница 84: ...dex 5 5 Operational Inspection Checking the Operation of the Front Panel Keys and Touch Panel With the power turned on operate all the front panel keys and the function menus displayed on the touch pa...

Страница 85: ...Replacing Fuses There is a fuse inside the instrument However you should not replace the fuse yourself It could indicate additional internal damage If you believe the fuse is blown please contact your...

Страница 86: ...oint Sample point setting for using the smoothing function is missing 15 Marker Setting changed The Marker type was changed to Normal Marker 17 Level Unit changed The LEVEL UNIT key setting was change...

Страница 87: ...n incorrect file name 126 Directory already exists Directory cannot be created because a directory of the same name already exists 127 File already exists File cannot be created because a file of the...

Страница 88: ...ument s calibration data 205 Internal communication error An abnormality occurred during instrument internal communication 206 Internal communication error An abnormality occurred during instrument in...

Страница 89: ...riables 322 Overflow An overflow occurred in an arithmetic operation 323 Undefined marker variable A command containing a marker value variable was executed when no marker had been displayed 324 Inval...

Страница 90: ...ose d une source de lumi re de r f rence int gr e pour les ajustements d alignement La lumi re infrarouge est toujours mise depuis le connecteur de sortie optique Ne regardez jamais directement dans l...

Страница 91: ...connecteur de sortie optique La lumi re infrarouge risquerait de gravement vous blesser ou de provoquer une perte de vision 1 Turn the power OFF 2 Remove the connector adapter from the instrument For...

Страница 92: ...ght or excessive dust Where water droplets can contact the instrument or where high humidity can cause them to form on the instrument Where active gas is present or where the instrument may be subject...

Страница 93: ...e Refer to the table below as a general guideline For part replacement and purchase contact your nearest YOKOGAWA dealer Parts with Limited Service Life Part Name Replacement Period LCD backlight At n...

Страница 94: ...2 3 4 5 6 App Index 5 11 Disposal When disposing of the YOKOGAWA produts follow the laws and ordinances of the country or region where the product will be disposed of If you are disposing of the produ...

Страница 95: ...ed resolution calibration using an external DFB LD Minimum sampling resolution1 0 001 nm Wavelength sampling points 101 to 200001 AUTO Level sensitivity setting TRAD mode NORM_HOLD NORM_AUTO NORMAL MI...

Страница 96: ...1 7 9 0 2 s NORM_AUTO 1 s NORMAL 2 s MID 5 s HIGH1 20 s HIGH2 75 s HIGH3 Optical return loss11 Typ 35 dB with angled PC connector Warm up time At least 1 hour After warm up ends alignment adjustment w...

Страница 97: ...ilt in wavelength reference light source or single longitudinal mode laser peak level 20 dBm or higher absolute waveform accuracy in the wavelength range of 1520 to 1560 nm 0 003 nm or less 6 With the...

Страница 98: ...rve fitting Other Trace copy trace clear write mode fixed mode setting show hide setting Marker and search Marker Delta markers up to 1024 markers power spectral density markers power integral markers...

Страница 99: ...2 3 4 5 6 App Index 6 2 External Dimensions Unit mm approx inch Unless otherwise specified tolerances are 3 however tolerances are 0 3 mm when below 10 mm 426 16 77 13 13 0 51 19 6 0 77 221 8 70 0 59...

Страница 100: ...require you to return the software with the entire device on which the software is installed for a refund or credit if any 1 Overview a Applicability This agreement applies to the Windows software th...

Страница 101: ...dware or software you use to multiplex or pool connections or reduce the number of devices or users that access or use the software does not reduce the number of licenses you need You may only use suc...

Страница 102: ...nsed and the software has been properly activated with a genuine product key or by other authorized method When you connect to the Internet while using the software the software will automatically con...

Страница 103: ...t mail it to Microsoft Corporation ATTN LCA ARBITRATION One Microsoft Way Redmond WA 98052 6399 Tell us your name address how to contact you what the problem is and what you want A form is available a...

Страница 104: ...rmal negotiation and arbitration 9 Governing Law The laws of the state or country where you live or if a business where your principal place of business is located govern all claims and disputes conce...

Страница 105: ...this notice THIS PRODUCT IS LICENSED UNDER THE AVC THE VC 1 AND THE MPEG 4 PART 2 VISUAL PATENT PORTFOLIO LICENSES FOR THE PERSONAL AND NON COMMERCIAL USE OF A CONSUMER TO i ENCODE VIDEO IN COMPLIANCE...

Страница 106: ...FOR BREACH OF A WARRANTY GUARANTEE OR CONDITION YOUR LOCAL LAWS IMPOSE TO THE EXTENT NOT PROHIBITED BY YOUR LOCAL LAWS IF YOU HAVE ANY BASIS FOR RECOVERING DAMAGES YOU CAN RECOVER FROM THE MANUFACTURE...

Отзывы: