Safe Usage 

–– Warnings & Cautions on Environment and Usage

Environmental Warnings / Cautions     –– Warning    –– Caution

KEEP  THE  THERMOMETER
AWAY FROM DROPPING WATER
AND DO NOT USE IN WATER.

This thermometer has waterproof-
ing, but it cannot be operated in the
water.  Water drops on the filter or
the area around it may cause incor-
rect measurement.  Wipe up the fil-
ter and the area around it completely
before taking measurement.

KEEP  THE  THERMOMETER
AWAY FROM DIRECT SUNLIGHT,
DUST,  HIGH TEMPERATURES
AND HIGH HUMIDITY DURING
USE AND STORAGE.

This may cause irreparable damage or
incorrect measurement.
e.g. Leaving the thermometer in a car
under a burning sun for long may result
in damage as it will get hot inside the car.

Usage Warnings / Cautions     –– Warning    –– Caution

4

GGGGGGGGG

DO  NOT  EXPOSE THE THER-
MOMETER TO  SUDDEN TEM-
PERATURE CHANGES.

Sudden temperature changes may
cause  incorrect  measurement.
Leave the thermometer for a while
to let it reach stable temperature
before taking measurement.

AVOID MEASURING SHINY OB-
JECTS.

Shiny objects, of which emissivity value
is near 0, reflect surrounding tempera-
tures.  As this thermometer's sensitiv-
ity to emissivity is fixed at 0.95 / 0.70,
the displayed temperature could differ
from the actual temperature of objects,
which has different emissivity value.
(See "Emissivity" on page 14)

DO  NOT  USE  ANY  BATTERY
OTHER THAN SPECIFIED.

This may cause irreparable dam-
age or incorrect measurement.

DO NOT TOUCH THE FILTER.

Do not touch the filter with some-
thing  hard  or  things  with  sharp
points, which may damage the fil-
ter.  Damaged filter causes incor-
rect measurement.

DO NOT LET THE THERMOM-
ETER TOUCH THE OBJECT THAT
IS BEING MEASURED.

The unit is a non-contact thermom-
eter.  Touching or getting too close
to the objects with high tempera-
tures may cause irreparable dam-
age or incorrect measurement.

DO NOT OPERATE THE THER-
MOMETER NEAR LARGE ELEC-
TROMAGNETIC FIELDS.

Usage in such environments may
cause irreparable damage or incor-
rect measurement.

KEEP  THE  THERMOMETER
AWAY  FROM  CHARGED  OB-
JECTS.

This may cause irreparable dam-
age or incorrect measurement.

DO NOT DROP THE THERMOM-
ETER  OR  APPLY  VIOLENT
SHOCKS.

This product has shock resistant
structure to survive under normal
usage, but throwing or falling the
unit intentionally with force  may
cause irreparable damage.

53008-E  12.5.12 1:12 PM  ページ 3

Содержание 53008

Страница 1: ...product in a place except for home Registration No Equipment Name Trade Name Manufacturer Country of Origin KCC REM IMY EEN326 Emission Thermometer Yokogawa Meter Instruments Corporation Yokogawa Met...

Страница 2: ...surface of an ob ject into temperature This thermometer measures the surface temperature of solid and liquid without contacting them The temperature of gas cannot be measured by this thermometer Cont...

Страница 3: ...sult in hazardous radiation exposure Safe Usage When operating the instrument be sure to observe the cautionary notes given below to ensure correct and safe use of the instrument If you use the instru...

Страница 4: ...alue is near 0 reflect surrounding tempera tures As this thermometer s sensitiv ity to emissivity is fixed at 0 95 0 70 the displayed temperature could differ from the actual temperature of objects wh...

Страница 5: ...0 Accuracy 0 95 0 to 200 C 2 C 201 to 500 C 1 Repeatability 1 C of reading value Display resolution 1 C Sighting method Non coaxial laser marker Class 2 HOLD time 15 seconds Continuous measurement mod...

Страница 6: ...e is no button to turn ON OFF the power supply Pressing MEASURE button wakes up the thermometer The power supply turns off automatically after 15 seconds absence of pressing any button Name of Compone...

Страница 7: ...s a Class 2 laser prod uct as defined by IEC60825 1 Safety of Laser Products Part1 Equipment classi fication and requirements In addition this instrument complies with 21 CFR 1040 10 except for deviat...

Страница 8: ...matically after 15 seconds NOR HOLD can be changed into MAX MIN HOLD See Setting on page 15 Continuous Measurement Starting Continuous Measurement qPress and hold both of MEASURE button and SET ENTER...

Страница 9: ...away from the measuring object unless there is any obstacle However please note that the measuring field of view enlarges in proportion to the measuring distance This thermometer has an optical resolu...

Страница 10: ...ess and hold CALL button for two seconds or more in HOLD Mode refer to page 8 and CALL sign appears on the LCD display In CALL recalling mode the last record of tem perature data and the corresponding...

Страница 11: ...page 14 Record Erasing HOLD mode Selections refer to page 15 rWhen each setting is completed it automatically turns to the next setting mode For example when setting of High Limit Temperature for Alar...

Страница 12: ...Limit Temperature for Alarm cannot be set at lower temperature than Low Limit Temperature for Alarm Turning ON OFF Alarm Function qWhen the High Limit Temperature setting is completed the setting mod...

Страница 13: ...the displayed value as the Low Limit Temperature for Alarm Note The Low Limit Temperature for Alarm cannot be set at higher temperature than High LimitTemperature for Alarm Turning ON OFF Alarm Funct...

Страница 14: ...f data Emissivity Emissivity is a value that indicates the infrared energy emitted from the surface of an object Every object has its own emissivity value and it varies depending on the surface condit...

Страница 15: ...The measured object is smaller than the field of view Adjust the measuring distance referring to the Field of view described in page 9 The thermometer is affected by a nearby heating source Cut off t...

Страница 16: ...rmation or damage Periodical Inspection It is recommended that the thermometer be calibrated annually For further information please contact the vendor from which you purchased the product Battery Bat...

Страница 17: ...17...

Страница 18: ...18...

Отзывы: