RADIO: 2000W TIMED RELAY MODULE
Functions
This module may be used in wireless mode and by one or more
additional local pushbuttons.
Technical Specifications
Mains voltage: 230V
~
±15% - 50Hz
Power on resistive load: Max. 10A 2000W
Power on other loads: please refer to the provided booklet
DS1054-022
Module consumption: < 1VA - < 0.3W
Radio frequency: 2.4GHz
Sound level: <60dB a 20 cm
Ambient temperature: from -20°C to +40°C
Relative humidity: 0 - 70%
Dimensions: 48 x 33 x 22.5 mm
[1.96 x 1.30 x 0.88”]
MTR2000MRP
5454464
2000W modular radio contactor
MTR2000MRPX
5454465
2000W modular radio contactor with
external antenna
RAdIO RANGe
Standard Range:
•
In the same room (< 100 m²)
• 50 m in open range
POWeR Range (*):
•
Inside 100 m² apartments with
perpendicular crossing of main wall or
ceiling
• 250 m in open range
(
Note: in both cases the range may be
reduced by the presence of metallic
elements, crossing of walls, or partitions
)
RAdIO TRANSMISSION
The transmitter Led will light up only if
the radio transmission was successful.
Adding an intermediate receiver will solve
the problem of an insufficient range.
Refer to the transmitter instruction booklet
for more information.
Special features of the MTR2000MRP(X):
Switches may be used instead of pushbuttons
with the MTR2000MRP(X) receiver (an E2BP transmitter
must be used).
To establish a connection, switch
5
times rapidly (not 10!), instead of 5 pulses. Simply repeat the connection
procedure with 5 pulses to use a pushbutton instead of the switch again.
WIRING
IMPORTANT
:
Before starting any configuration, press briefly
23
times to unlock the relay.
The module will lock again automatically after
6 hours.
It can also be locked immediately with
21
short
presses.
DS1054-023D
P8
(*) Contact an Urmet retailer or go to www.yokis.com for information on availability
GB
Installing Cautions
The module must be installed only by qualified
personnel and into a place the end-user cannot
access, according to the installing national rules.
In order to follow the safety rules, the module must
be connected to a power line that is upstream pro-
tected by a magnetothermic switch 10A C curve.
Except MTV500ER, for all other YOKIS radio
receiver modules you must use a pointed and pro-
perly insulated tool to press the “connect” hole
shortly.
Connection
button
3 wires
4 wires
Test button
State light