YMGI WMMS-09EW-V2B Скачать руководство пользователя страница 7

BRIEF UNIT INFO

MUST READ

P11 OF 40

P12 OF 40

IMPORTANT NOTES

These precautions are essential and must be strictly observed.

DO NOT

 pull on the power cord or refrigeration lines. 

Install them in a secured position. A line set plastic 
cover is recommended.

DO NOT

 install the unit in places where there is 

exposure to flammable materials or gas leakage. 

DO NOT

 use wire or circuit breakers that do not meet 

electrical safety standards.  Several circuits cannot 
be connected to one breaker.

DO NOT

 wire or open the unit while it is running. 

Make sure to shut off all circuits prior to inspecting or 
servicing the unit.

DO NOT

 install unit in a damp laundry room or near 

flammable gas. All units must be protected by 
certified electrical circuit breakers and in accordance 
with all safety codes.

DO NOT

 use the unit in cool or dry mode for 

prolonged periods where humidity is higher than 80%. 

SAFETY WARNINGS

READ THESE SAFETY WARNINGS COMPLETELY PRIOR TO ANY USE 

DO NOT

 install the indoor unit close to cooking 

surfaces or ventilation systems. Poor placement 
could inhibit peak performance.       

DO NOT

 blow cold air directly towards people for 

extended periods.

DO NOT

 use chemical solvents, flammable 

insecticides, or abrasive materials. Clean the unit 
only with a soft dry cloth or rag.

DO NOT

 continue to operate the unit if there is any 

abnormal odor, burning, scorching, or smoke. Stop 
and disconnect the unit immediately.

DO NOT

 use the system for anything other than what 

it was designed for or any non-HVAC purposes. Do 
not store near food, paint, or other chemicals.

DO NOT

 operate the unit for prolonged periods 

without refreshing ambient air. Opening a door or 
window periodically will suffice.

DO NOT

 draw on the power cord or refrigeration

lines. Install them in secured positions. Plastic
cover of line set is recommended.

DO NOT

 blow the cold air directly towards people

for prolonged period. Otherwise, people may get
cold.

DO NOT

 use smaller than enough wires. Do not

put several circuits to one breaker. Don't use
smaller than enough circuit breakers. Otherwise
power failure or fire may be caused.                

DO NOT

 wire or open unit while unit is running.

Sparks or fire may occur. It may cause a shock to
people. 

Ground connection

Forbidden

Disconnect the plug

Imperative

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

* Your technician will then need to verify and confirm the problem(s) before YMGI can ship out the replacement part(s). 
  Inaccurate or incomplete troubleshooting or part replacement will delay the repair. YMGI technical support will only speak 
  with a licensed/certified technician in regards to the repair of your unit.  In our experience this saves time and money for 
  all parties involved.

Your technician is the only person to perform any physical checking, trouble-shooting and replacing of any 
defective part(s) for your units. Our factory technical support is just a help.  

YMGI provided no labor warranty 

on the products.

 

2. Unit/part repair at our workshop(s):

  Due to the limitations of our technical support not being at your job site, 

    or your technician's experience with our product, the problem may not be resolved as quickly as would be 
    desired.

 

If the problem is still not resolved after attempts between your technician and our technical support, 

    you can elect to have the unit repaired at our facility.  If this step is chosen:

1) YMGI will send to you the 

Customer Request to Ship Products to YMGI Service Center for Inspection and Repair, 

    and Authorization to Charge 

form.

2) You will review the form and fill all fields appropriately, sign and send back to the YMGI Group.
3) Once the form has been completed and sent back to YMGI, remove the units and ship back to YMGI.

Please make a note describing the problem and communication history, if possible. Our technicians will check the 
units and find the problem(s), repair the issue(s), and ship the unit back to you following the conditions set forth in 
the signed repair agreement. All unit removal and re-installation is done at your cost

 

and must be done by a 

currently valid licensed HVAC technician.

3. Unit replacement:

 Only applies to those defects reported within 30 days of original purchase date

 

and if all 

    necessary warranty paperwork had been received and approved. This option applies only if the above steps 
    cannot resolve the problem(s). Either indoor or outdoor unit replacement is available, based on the actual need, 
    at YMGI's determination. 

This option shall be the last resort

, due to refrigerant and wiring considerations. All 

    unit removal, re-installation and shipping cost are the responsibility of the customer.

 

YMGI maintains the final 

    authority as to unit replacement.  Replacement will be made with the same model only.  Alternate units will be 
    treated as a new order. 

Returning Replaced Defective Units/Parts/Accessories After Unit Repair: (

Only applies to steps 1&3 above)

1) Repack the replaced unit/ part /accessory in the box which contained the replacement part. 
2) Parts can be boxed for UPS, FedEx or equivalent ground service. Units shall be secured onto the skid on which the 
    replacement was shipped after placing into the

 

package from the replacement

 

product.

3) Ship 

all

 replaced products, to YMGI-designated location. You will be charged if YMGI does not receive the replaced parts.

Standard factory warranty does not cover the cost of materials and labor that are incurred at your site. 
There will be no cost for the replacement unit, if YMGI determines the defect is manufacturer related. 
Replacement will be made with the same model,

 

only.  Alternate units will be treated as a new order.

CUSTOMER SERVICE / TECHNICAL SUPPORT FROM YMGI GROUP

For questions or help with your unit, contact the original installer or service provider.
YMGI Group does not install nor physically service your unit. Your installer or service provider must check the 
unit prior to contacting YMGI Group from your jobsite, in order to be helped in an efficient and timely manner.
* Factory customer service at [email protected] Tel: 1-866-833-3138x704
* Factory technical support at [email protected] Tel: 866-833-3138x703
* Fax: 1-866-377-3355
An 

"YMGI Group Customer Service/Technical Support Daily Log Sheet"

 will be filed in writing at our office, 

for effective communication between you and YMGI Group customer service, your technician and YMGI Group 
technical support. Before contacting the YMGI Group locate the IP# written at the top of your warranty registration 
form.  Use this IP# whenever you contact the YMGI Group.

DISTRIBUTOR AND MANUFACTURER POLICIES

* All questions concerning sales or money will be directed to the sales distributor from which you purchased the 
  units.
* Read and follow all policies set forth from the distributor from which you purchased your unit.
* Upon purchase and installation of the unit(s), you agree to be bounded by all policies published by both 
  distributors and YMGI.
* MGI Group has the final authority and supersedes other related parties (distributors, etc.) concerning all policies 
  regarding YMGI products.

CUSTOMER AND TECHNICIAN MUST READ

Содержание WMMS-09EW-V2B

Страница 1: ...pment NEC State City or Local Codes and related manuals from us Otherwise damage to equipment or property even injury to people may occur Installer Currently licensed HVAC installer only Read this man...

Страница 2: ...ory labs third party labs and various fields applications following related industrial and company standards 7 Field installation details matter with all 1 if your units will work correctly and proper...

Страница 3: ...ty approval because warranty is approved only to those qualified and successful installations by qualified HVAC technician I know the warranty if approved is a standard 5 year compressor and 1 year ot...

Страница 4: ...eral knowledge and experience a full single head installation may normally cost anywhere from 800 to 1500 These costs are estimates and your actual costs may differ due to job nature and location 8 Nu...

Страница 5: ...D MUST READ MUST READ P7 OF 40 P8 OF 40 YMGI Engineered Comfort Products for A Sustainable and Efficient Green World YMGI Engineered Comfort Products for A Sustainable and Efficient Green World The co...

Страница 6: ...t Green World YMGI Engineered Comfort Products for A Sustainable and Efficient Green World If the damage is minor or partial that you choose to accept you can contact the distributor or YMGI to discus...

Страница 7: ...he Customer Request to Ship Products to YMGI Service Center for Inspection and Repair and Authorization to Charge form 2 You will review the form and fill all fields appropriately sign and send back t...

Страница 8: ...copper tube Aluminum fin copper tube Swing Motor Model MP28VB 1 4 3 8 MP28EC MP35XX Output of Swing Motor W 2 2 2 5 Fuse A PCB 3 15A Transformer 0 2A PCB 3 15A Transformer 0 2A PCB 3 15A Transformer 0...

Страница 9: ...WS DIMENSIONS MOUNING BRACKET CLEARANCE YMGI Engineered Comfort Products for A Sustainable and Efficient Green World YMGI Engineered Comfort Products for A Sustainable and Efficient Green World WMMS 0...

Страница 10: ...this mode only indoor fan is running at setting status Under auto fan speed it will run by cooling auto fan Heating Mode When the indoor receiving the information mode clash from outdoor unit and the...

Страница 11: ...ter setting sleep procedure 1h T preset will increase 1 F 2h later T preset will O O increase 2 F then remain the temperature T preset will not exceed 86 F under heating after setting sleep O O proced...

Страница 12: ...ER 4 OVER 80 CLEARANCE REQUIRED AROUND UNITS DUAL ZONE 2 YMGI Engineered Comfort Products for A Sustainable and Efficient Green World YMGI Engineered Comfort Products for A Sustainable and Efficient G...

Страница 13: ...E REQUIRED AROUND UNITS QUAD ZONE OVER 2 OVER 4 OVER 4 OVER 80 YMGI Engineered Comfort Products for A Sustainable and Efficient Green World YMGI Engineered Comfort Products for A Sustainable and Effic...

Страница 14: ...for screws Align mounting plate holes with those holes drilled on the wall and put anchors or screws into the holes to secure mounting plate Steps To Mount Plate a b c Drill mounting holes to make su...

Страница 15: ...ipes need to come out of the bottom side facing the front of indoor unit of the indoor unit snap off portion 2 on plastic casing If pipes need to come out of the left side facing the front of indoor u...

Страница 16: ...N INDOOR AND OUTDOOR UNITS Firstly connect copper tubes at indoor unit Bend pipes by tools but not by hands Extra length is needed for future service REFRIGERANT PIPES For distance other than 25 betwe...

Страница 17: ...25 26 27 28 29 30 Jumping connector 1 32 Transformer 48X26P 1 33 Wire clamp 1 34 Rear clamp 1 35 Connecting cable 1 36 swing louver clamp 1 37 swing louver 1 38 swing louver up 1 39 swing louver down...

Страница 18: ...e 68012019 1 Receiver board 30545042 1 Front panel 200022921 1 Guide louver 261120432 1 Guide louver 261120422 1 Motor MP28EC 15212002 1 Right motor clamp 26112429 1 Bearing holder 26152423 1 Motor FN...

Страница 19: ...2 Front case 200026524 1 Front panel 2000284402 1 remote control YT1F 30510049 1 Displaying light board 22432071 1 Electric box cover 1 20112019 1 Wire clamp 71010103 1 Terminal board 4201026601 1 El...

Страница 20: ...mfort Products for A Sustainable and Efficient Green World DISASSEMBLY PROCEDURE OPERATING PROCEDURES PHOTOS Disassemble Front Panel Lift the front panel upward Firstly screw off a screw fixing the up...

Страница 21: ...ny damages to person or property of whatever kind direct or indirect special or consequential whether resulting from use or loss of use of the product The original licensed installer or current servic...

Отзывы: