BRIEF UNIT INFO

P19 OF 40

P20 OF 40

Cold Plasm Function

Remote control the cold plasm function to ON and turn on the cold plasm when the fan motor is ON; remote 
control the cold plasm to OFF or turn off the cold plasm when the dan motor is OFF.

Unit Display

Basic Display

1) When the unit is energized, the display symbol display, then only power lamp is light.
2) When use remote control to turn on the unit, the running LED is light, and the current setting running mode 
    lamp displayed at the same time.
COOLING: running lamp and cooling lamp are light; HEATING: running lamp and heating lamp are light;
DRY: running lamp and dry lamp are light; FAN: running lamp and fan lamp are light;
AUTO: auto lamp, running lamp and actual running mode lamp are light.
(3) If turn off the LIGHT button, all the display is off (it is valid when the unit is OFF).
(4) After set SLEEP function, the display maintains the original display status, it means the light switch does not
influence sleep function.

Dual-8 Display

O

If the digital pipe display current setting temperature, the setting temperature range is 61-86 F. It will display 

O

O

O

77 F for cooling and fan under auto mode, and display 68 F for heating, and the cooling controller displays 77 F. 

O

The temperature range is 32-86 F when the indoor temperature displays.

Fan Speed Display

There are 3 status dynamic circle display for fan symbol, they are middle two segments, middle four segments 
and display six segments, and the middle two segments is displaying. The fan speed symbol blinks the fastest 
when remote control super-fan; the fan speed symbol blinks the lowest when remote control low-fan; the blink 
speed of display symbol is between high fan and low fan when remote control med fan; the blink speed of display 
depends on the indoor actual running speed when remote control auto fan speed; if the indoor fan motor stops, it 
blink display at the lowest speed.

Indoor Unit Malfunction Lamp Display

Note: The malfunction code will circulate display when different malfunctions exist together. The indicator will light 
0.5S and display 0.5S when it blinks. The indoor temperature sensor malfunction will not be inspected during 
defrost, or oil return period.

The system is abnormal (anti-high temp. power off, cooling overload)

Compressor overload protection

H3

Blink 3 times

Module protection

High-pressure protection

Anti-freeze protection power-off

Discharge temperature protection

Low voltage over-current protection

Mode clash

Communication malfunction

The indoor ambient temperature sensor is open, short circuit

Any indoor evaporator temperature sensor is open, short circuit

The outdoor ambient temperature sensor is open, short circuit

The outdoor condenser temperature sensor is open, short circuit

The outdoor discharge temperature sensor is open, short circuit

Defrost or heating oil return

Fail to start up

PFC malfunction

Compressor demagnetizing protection

The malfunction below need used by  to be remote control, it will display when press sleep button 6 times continuously in 3S, and exit 
inspect state(it is not valid under auto mode) automatically in 5min, or will exit when press sleep button 6 times continuously in 3S.

Mal Malfunction Name

Dual-8 Display Running Lamp Heating Lamp Cooling Lamp

H4

H5

E1

E2

Blink 4 times

Blink 5 times

Blink once

Blink twice

E4

E5

E7

E6

H1

Blink 4 times

Blink 5 times

Blink 7 times

Blink 6 times

Blink once

F1

F2

F3

F4

F5

H7

HC

HE

Blink once

Blink twice

Blink 3 times

Blink 4 times

Blink 5 times

Blink 7 times

Blink 6 times

Blink 14 times

Cooling overload down frequency

Unit overflow down frequency

Compressor discharge down frequency

Unit AC voltage decreasing down frequency

Heating anti-high temperature down frequency

Anti-cool air protection

Cooling oil return

F6

F8

F9

E0

H0

E9

F7

Blink 6 times

Blink 8 times

Blink 9 times

Blink 10 times

Blink 10 times

Blink 9 times

Blink 7 times

REMOTE CONTROL & UNIT FUNCTIONS

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

O

In cooling and fan mode, after setting sleep procedure 1h, T preset will increase 1 F; 2h later, T preset will 

O

O

increase 2 F, then remain the temperature, T preset will not exceed 86 F; under heating, after setting sleep 

O

O

procedure 1h, T preset will decrease 1 F; 2h later, T preset will decrease 2 F, then remain the temperature, 

O

T preset will not exceed 61 F; the setting temperature will not change under fan and auto mode.

Timer Function

General timer:
a. TIMER ON: The timer on can be set when the unit is OFF, the controller will run under original setting mode
when the time of timer on reaches, the timer space is 0.5h, and setting range is 0.5-24h.

b. TIMER OFF: The timer off can be set when the unit is ON, the unit is OFF when the timer time reaches, the
timer space is 0.5h, and setting range is 0.5-24h.

Clock timer:
a. TIMER ON: If set timer on when the unit is running, it will keep running. if set the timer on when the unit is off,
the unit will run with the pre-setting mode when the time of setting timer on reaches.

b. TIMER OFF: If set timer off when the unit is off, when setting timer off, the unit will maintain stand-by status; if
set timer off when the unit is on, when the time of setting timer off reaches, the system will stop to run.

c. TIMER changing: When the unit under timer status, it can set ON and OFF by remote control, and reset timer
time, the unit will run under the last setting status.

Set timer on and timer off together when the unit is running, the unit will maintain the current status, once the time
of setting timer off reaches, the unit will stop to work.

Set timer on and timer off together when the unit is off, the unit will maintain off status until the time of timer on
reaches, the unit will start to work, hereafter the time of timer on reaches everyday, the unit will run under the
original setting mode, and the unit stop to work when the time of timer off reaches.

When the time of setting timer on and setting timer off is the same, the unit is off.

Memory Function

Memory contents: mode, swing (up and down), light, set Temp., set fan speed, general timer (clock timer doesn't 
memory)

The unit will on automatically with memory content after re-energized.

There is no setting timer function in the last remote control order, and the system memory the last remote control
order and working under that setting method.

There is general timer function in the last remote control order, the system is energized before the timer time
haven't reach, the unit will memory timer function of the last remote control order after re-energized, and the 
timer time will star to calculate after re-energized.

There is timer function in the last remote control order, but the timer time reaches, the system will de-energize 
after timer on and timer off, after re-energized, the system will memory the running status which before power-off, 
and no timer action; the clock timer doesn't memory.

U-TOUCH Function

If controller receives U-TOUCH command, it will run at the ambient temp sent by remote control (but it will also 
run at sampling temp. of AC temp sensor itself except defrost and anti-cool air). The remote control will send 
ambient temp to controller every 10min, so if the controller hasn"t received ambient temp from remote control 
after 11min, it will run at temp. of AC itself. If this function is not set, all ambient temp will adopt sampling value of 
AC temp. sensor itself.

Turbo Function

The TURBO function can be set only under COOLING and HEATING mode, when controller receiving turbo 
order, the indoor fan motor will run with high speed, and send turbo signal and high speed to outdoor unit.

After energization, up & down swing motor will totate guide louver to position 0 
to close air outlet. After turn on the unit, if swing function has not been set, up & 
down guide louver will clockwise turn to position D under heating mode, or 
clockwise turn to level position L1 under other modes. If the unit is turn on with 
swing function setting, guide louver will swing between L and D. There are 7 
kinds of swing states of guide louver. Position L,A,B,C,D, swing between L and 
D, stop between L and D (included angle L and D is equiangular). Upon stop of 
unit, guide louver will close to position 0. Swing action is valid only when swing 
command is set and indoor fan is running.

Swing (up and down) Control

REMOTE CONTROL & UNIT FUNCTIONS

Sleep Function

Содержание WMMS-09EW-V2B

Страница 1: ...pment NEC State City or Local Codes and related manuals from us Otherwise damage to equipment or property even injury to people may occur Installer Currently licensed HVAC installer only Read this man...

Страница 2: ...ory labs third party labs and various fields applications following related industrial and company standards 7 Field installation details matter with all 1 if your units will work correctly and proper...

Страница 3: ...ty approval because warranty is approved only to those qualified and successful installations by qualified HVAC technician I know the warranty if approved is a standard 5 year compressor and 1 year ot...

Страница 4: ...eral knowledge and experience a full single head installation may normally cost anywhere from 800 to 1500 These costs are estimates and your actual costs may differ due to job nature and location 8 Nu...

Страница 5: ...D MUST READ MUST READ P7 OF 40 P8 OF 40 YMGI Engineered Comfort Products for A Sustainable and Efficient Green World YMGI Engineered Comfort Products for A Sustainable and Efficient Green World The co...

Страница 6: ...t Green World YMGI Engineered Comfort Products for A Sustainable and Efficient Green World If the damage is minor or partial that you choose to accept you can contact the distributor or YMGI to discus...

Страница 7: ...he Customer Request to Ship Products to YMGI Service Center for Inspection and Repair and Authorization to Charge form 2 You will review the form and fill all fields appropriately sign and send back t...

Страница 8: ...copper tube Aluminum fin copper tube Swing Motor Model MP28VB 1 4 3 8 MP28EC MP35XX Output of Swing Motor W 2 2 2 5 Fuse A PCB 3 15A Transformer 0 2A PCB 3 15A Transformer 0 2A PCB 3 15A Transformer 0...

Страница 9: ...WS DIMENSIONS MOUNING BRACKET CLEARANCE YMGI Engineered Comfort Products for A Sustainable and Efficient Green World YMGI Engineered Comfort Products for A Sustainable and Efficient Green World WMMS 0...

Страница 10: ...this mode only indoor fan is running at setting status Under auto fan speed it will run by cooling auto fan Heating Mode When the indoor receiving the information mode clash from outdoor unit and the...

Страница 11: ...ter setting sleep procedure 1h T preset will increase 1 F 2h later T preset will O O increase 2 F then remain the temperature T preset will not exceed 86 F under heating after setting sleep O O proced...

Страница 12: ...ER 4 OVER 80 CLEARANCE REQUIRED AROUND UNITS DUAL ZONE 2 YMGI Engineered Comfort Products for A Sustainable and Efficient Green World YMGI Engineered Comfort Products for A Sustainable and Efficient G...

Страница 13: ...E REQUIRED AROUND UNITS QUAD ZONE OVER 2 OVER 4 OVER 4 OVER 80 YMGI Engineered Comfort Products for A Sustainable and Efficient Green World YMGI Engineered Comfort Products for A Sustainable and Effic...

Страница 14: ...for screws Align mounting plate holes with those holes drilled on the wall and put anchors or screws into the holes to secure mounting plate Steps To Mount Plate a b c Drill mounting holes to make su...

Страница 15: ...ipes need to come out of the bottom side facing the front of indoor unit of the indoor unit snap off portion 2 on plastic casing If pipes need to come out of the left side facing the front of indoor u...

Страница 16: ...N INDOOR AND OUTDOOR UNITS Firstly connect copper tubes at indoor unit Bend pipes by tools but not by hands Extra length is needed for future service REFRIGERANT PIPES For distance other than 25 betwe...

Страница 17: ...25 26 27 28 29 30 Jumping connector 1 32 Transformer 48X26P 1 33 Wire clamp 1 34 Rear clamp 1 35 Connecting cable 1 36 swing louver clamp 1 37 swing louver 1 38 swing louver up 1 39 swing louver down...

Страница 18: ...e 68012019 1 Receiver board 30545042 1 Front panel 200022921 1 Guide louver 261120432 1 Guide louver 261120422 1 Motor MP28EC 15212002 1 Right motor clamp 26112429 1 Bearing holder 26152423 1 Motor FN...

Страница 19: ...2 Front case 200026524 1 Front panel 2000284402 1 remote control YT1F 30510049 1 Displaying light board 22432071 1 Electric box cover 1 20112019 1 Wire clamp 71010103 1 Terminal board 4201026601 1 El...

Страница 20: ...mfort Products for A Sustainable and Efficient Green World DISASSEMBLY PROCEDURE OPERATING PROCEDURES PHOTOS Disassemble Front Panel Lift the front panel upward Firstly screw off a screw fixing the up...

Страница 21: ...ny damages to person or property of whatever kind direct or indirect special or consequential whether resulting from use or loss of use of the product The original licensed installer or current servic...

Отзывы: