TROUBLESHOOTING
POSSIBLE CAUSES
SOLUTIONS
UNIT DOES NOT START
Unit may have become unplugged
Fuse may have blown
Circuit breaker may have been tripped
Unit may be off or in wall thermostat mode.
Check section on dipswitch settings to verify
dipswitches are set properly.
Unit may be in a protection or diagnostic failure
mode.
See section on diagnostic codes.
Check that plug is plugged securely in wall receptacle.
Note: Plug has a test/reset button on it. Make sure that the
plug has not tripped.
Replace the fuse.
Reset circuit breaker.
Turn unit on (bottom right button on keypad).
DISPLAY HAS STRANGE
NUMBERS/CHARACTERS
ON IT
The unit may be in a diagnostic condition. Check diagnostic
codes --- checking Control section to determine if unit has had
a failure.
The unit may be set for ° C (instead of ° F), see the
SENIOR OPERATION
.
UNIT MAKING NOISES
•
Clicking, gurgling and whooshing noises are normal during
operation of unit.
UNIT NOT COOLING / HEATING ROOM
•
Unit air discharge section is blocked
•
Temperature setting is not high or low enough
•
Note: Set point limits may not allow the unit to
heat or cool the room to the temperature desired.
Check section on dipswitch settings.
•
Unit air filters are dirty.
•
Room is excessively hot or cold when unit is
started
•
Vent door left open
•
Unit may be in a protection or diagnostic failure
mode.
•
Check section on Intelligent Self --- checking
Control.
•
Compressor is in time delay. There is a protective
time delay (approx. 3 minutes) on starting the
compressor after a power outage (or restarting
after it has been turned off), to prevent tripping of
the compressor overload.
•
Make sure that curtains, blinds or furniture are not restricting
or blocking unit airflow.
•
Reset to a lower or higher temperature setting.
•
Remove and clean filters.
•
Allow sufficient amount of time for unit to heat or cool the
room.
•
Start heating or cooling early before outdoor temperature,
cooking heat or gatherings of people make room
uncomfortable.
•
Close vent door.
•
Check DIP switch settings for desired comfort.
•
Wait approximately 3 minutes for compressor to start.
WATER DRIPPING OUTSIDE
If a drain kit has not been installed, condensation runoff during
very hot and humid weather is normal. See Note 2. If a drain
kit has been installed and is connected to a drain system,
check gaskets and fittings around drain for leaks and plugs.
WATER DRIPPING INSIDE
Wall sleeve is not installed level
Wall sleeve must be installed level for proper drainage of
condensation. Check that installation is level and make any
necessary adjustments.
ICE OR FROST FORMS ON INDOOR COIL
•
Low outdoor temperature
•
Dirty filters
•
When outdoor temperature is approximately 55 °F (12.8°C) or
below, frost may form on the indoor coil unit is in Cooling
mode. Switch unit to FAN operation until ice or frost melts.
•
Remove and clean filters.
COMPRESSOR PROTECTION
•
Power may have cycled, so compressor is in a
restart protection.
•
Random Compressor restart
: Whenever the unit is plugged
in, or power has been restarted, a random compressor restart
will occur. After a power outage, the compressor will restart
after approximately 3 minutes.
•
Compressor Protection
: To prevent short cycling of the
compressor, there is a random startup delay of 3 minutes and
a minimum compressor run time of 3 minutes.
NOTES:
1.
If circuit breaker is tripped or fuse is blown more than once, contact a qualified electrician.
2.
If unit is installed where condensation drainage could drip in an undesirable location, an accessory drain kit should be installed and
connected to drain system.
Содержание PTAC Series
Страница 10: ...YMGI Your Modern Green Idea 10 ...
Страница 27: ...YMGI Your Modern Green Idea 27 ...
Страница 31: ...YMGI Your Modern Green Idea 31 NOTE See the Remote Thermostat Change instructions before using the thermostat ...
Страница 43: ...YMGI Your Modern Green Idea 43 PTAC Wiring Diagrams Wiring diagram PTAC Cooling Only 40 models ...
Страница 44: ...YMGI Your Modern Green Idea 44 Wiring diagram PTAC w Elec Heater 41 models ...
Страница 45: ...YMGI Your Modern Green Idea 45 Wiring diagram PTHP Heat Pump Wiring Drawing 7K 9K 12K 42 43 45 models ...
Страница 46: ...YMGI Your Modern Green Idea 46 Wiring diagram PTHP Heat Pump Wiring Drawing 15K heat pump 42 43 45 models ...
Страница 51: ...YMGI Your Modern Green Idea 51 ...