YMGI M2 SERIES Скачать руководство пользователя страница 9

INST

ALLER'S 

INSTRUCTION

BRIEF UNIT INFO

IMPORTANT NOTES-About System Performance:

1) The rated performance data is tested under one of the  indoor & outdoor conditions at standard set-up installation.
2) Actual performance varies upon many factors such as indoor and outdoor temperatures, inter-connecting  pipe length/bending, elevation 
    difference between indoor and outdoor units, refrigerant level, vacuum level, leakage,  air or moisture or other contamilation level, foreign 
    substance left in the piping, indoor filter cleaness, indoor  and outdoor coil conditions, and others.
3) The electrical driving voltage and frequency, as well as the mechanical performing pressures and temperatures,  at different operating points, 
    during different operating periods, at different operating conditions. Suggest to measure temepratures and  pressures several minutes after 
    starting, when unit is stablized.
4) May refer to other specification tables or engineering  submittals, for detailed system performance at different conditions.
5) System performance will be degraded, if systems are improperly  selected, operated, installed, maintained, or serviced (which are not 
    conducted by manufacturer).

MINI WALL MOUNT SYSTEMS-MODELS

Wall Mount Mini Split - Single Zone

Cooling Only

System Model

WMMS-09K-31A(B)

WMMS-12K-31A(B)

WMMS-18K-31B

WMMS-24K-31B

WMMS-30K-31B

WMMS-36K-31B

      Indoor Unit

WMMS-09E-31A(B)

WMMS-12E-31A(B)

WMMS-18E-31B

WMMS-24E-31B

WMMS-30E-31B

WMMS-36E-31B

Outdoor Unit

WMMS-09C-31A(B)

WMMS-12C-31A(B)

WMMS-18C-31B

WMMS-24C-31B

WMMS-30C-31B

WMMS-36C-31B

Heat Pump

System Model

WMMS-09K-32A(B)

WMMS-12K-32A(B)

WMMS-18K-32B

WMMS-24K-32B

WMMS-30K-32B

WMMS-36K-32B

Indoor Unit

WMMS-09E-32A(B)

WMMS-12E-32A(B)

WMMS-18E-32B

WMMS-24E-32B

WMMS-30E-32B

WMMS-36E-32B

Outdoor Unit

WMMS-09C-32A(B)

WMMS-12C-32A(B)

WMMS-18C-32B

WMMS-24C-32B

WMMS-30C-32B

WMMS-36C-32B

Heat Pump

/ Elec. Heat

System Model

WMMS-09K-34B

WMMS-12K-34B

WMMS-18K-34B

WMMS-24K-34B

WMMS-30K-34B

WMMS-36K-34B

      Indoor Unit

WMMS-09E-34B

WMMS-12E-34B

WMMS-18E-34B

WMMS-24E-34B

WMMS-30E-34B

WMMS-36E-34B

Outdoor Unit

WMMS-09C-32B

WMMS-12C-32B

WMMS-18C-32B

WMMS-24C-32B

WMMS-30C-32B

WMMS-36C-32B

Wall Mount Mini Split - Dual Zone

Cooling Only

System Model

      Indoor Unit

Outdoor Unit

Heat Pump

System Model

Indoor Unit

Outdoor Unit

Heat Pump

/ Elec. Heat

System Model

      Indoor Unit

Outdoor Unit

WMMS-2X09K-31B

WMMS-0912K-31B

WMMS-2X12K-31B

WMMS-2X18K-31B

WMMS-2X-24K-31B

WMMS-2X30K-31B

WMMS-09E(F)-31B

WMMS-09/12E(F)-31B

WMMS-12E(F)-31B

WMMS-18E(F)-31B

WMMS-24E(F)-31B

WMMS-30E(F)-31B

WMMS-2X09C-31B

WMMS-0912C-31B

WMMS-2X12C-31B

WMMS-2X18C-31B

WMMS-2X24C-31B

WMMS-2X30C-31B

WMMS-2X09K-32B

WMMS-0912K-32B

WMMS-2X12K-32B

WMMS-2X18K-32B

WMMS-2X24K-32B

WMMS-2X30K-32B

WMMS-09E(F)-32B

WMMS-09/12E(F)-32B

WMMS-12E(F)-32B

WMMS-18E(F)-32B

WMMS-24E(F)-32B

WMMS-30E(F)-32B

WMMS-2X09C-32B

WMMS-0912C-32B

WMMS-2X12C-32B

WMMS-2X18C-32B

WMMS-2X24C-32B

WMMS-2X30C-32B

WMMS-2X09K-34B

WMMS-0912K-34B

WMMS-2X12K-34B

WMMS-2X18K-34B

WMMS-2X24K-34B

WMMS-2X30K-34B

WMMS-09E(F)-34B

WMMS-09/12E(F)-34B

WMMS-12E(F)-34B

WMMS-18E(F)-34B

WMMS-24E(F)-34B

WMMS-30E(F)-34B

WMMS-2X09C-32B

WMMS-09/12C-32B

WMMS-2X12C-32B

WMMS-2X18C-32B

WMMS-2X24C-32B

WMMS-2X30C-32B

Wall Mount Mini Split - Triple Zone

Cooling Only

System Model

      Indoor Unit

Outdoor Unit

Heat Pump

System Model

Indoor Unit

Outdoor Unit

Heat Pump

/ Elec. Heat

System Model

      Indoor Unit

Outdoor Unit

WMMS-3X09K-31B

WMMS-3X12K-31B

WMMS-2X0912K-31B WMMS-2X-1218K-31B WMMS-2X1824K-31B

WMMS-1230K-31B

WMMS-09E(F)-31B

WMMS-09E(F)-31B

WMMS-09/12E(F)-31B WMMS-12/18E(F)-31B WMMS-18/24E(F)-31B WMMS-12/30E(F)-31B

WMMS-3X09C-31B

WMMS-3X12C-31B

WMMS-2X0912C-31B WMMS-2X1218C-31B WMMS-2X1824C-31B WMMS-2X1230C-31B

WMMS-3X09K-32B

WMMS-3X12K-32B

WMMS-2X0912K-32B WMMS-2X1218K-32B WMMS-2X1824K-32B WMMS-2X1230K-32B

WMMS-09E(F)-32B

WMMS-09E(F)-32B

WMMS-09/12E(F)-32B WMMS-12/18E(F)-32B WMMS-18/24E(F)-32B WMMS-12/30E(F)-32B

WMMS-3X09C-32B

WMMS-3X12C-32B

WMMS-2X0912C-32B WMMS-2X1218C-32B WMMS-2X1824C-32B WMMS-2X1230C-32B

WMMS-3X09K-34B

WMMS-3X12K-34B

WMMS-2X0912K-34B WMMS-2X1218K-34B WMMS-2X1824K-34B WMMS-2X1230K-34B

WMMS-09E(F)-34B

WMMS-09E(F)-34B

WMMS-09/12E(F)-34B WMMS-12/18E(F)-34B WMMS-18/24E(F)-34B WMMS-12/30E(F)-34B

WMMS-3X09C-32B

WMMS-3X12C-32B

WMMS-2X0912C-32B WMMS-2X1218C-32B

WMMS-2X1824-32B

WMMS-2X1230C-32B

Cooling Only

System Model

      Indoor Unit

Outdoor Unit

Heat Pump

System Model

Indoor Unit

Outdoor Unit

Heat Pump

/ Elec. Heat

System Model

      Indoor Unit

Outdoor Unit

Wall Mount Mini Split - Quad Zone

WMMS-4X09K-31B

WMMS-4X12K-31B

WMMS32X0912K-31B

WMMS-3X-1209K-31B

WMMS-2X(0912)K-31B

WMMS-09E(F)-31B

WMMS-12E(F)-31B

WMMS-09/12E(F)-31B

WMMS-12/09E(F)-31B

WMMS-09/12E(F)-31B

WMMS-4X09C-31B

WMMS-4X12C-31B

WMMS-3X0912C-31B

WMMS-3X1209C-31B

WMMS-2X(0912)C-31B

WMMS-4X09K-32B

WMMS-4X12K-32B

WMMS-3X0912K-32B

WMMS-3X1209K-32B

WMMS-2X(0912)K-32B

WMMS-09E(F)-32B

WMMS-12E(F)-32B

WMMS-09/12E(F)-32B

WMMS-12/09E(F)-32B

WMMS-09/12E(F)-32B

WMMS-4X09C-32B

WMMS-4X12C-32B

WMMS-3X0912C-32B

WMMS-3X1209C-32B

WMMS-2X(0912)C-32B

WMMS-4X09K-34B

WMMS-4X12K-34B

WMMS-3X0912K-34B

WMMS-3X1209K-34B

WMMS-2X(0912)K-34B

WMMS-09E(F)-34B

WMMS-12(E)F-34B

WMMS-09/12E(F)-34B

WMMS-12/09E(F)-34B

WMMS-09/12E(F)-34B

WMMS-4X09C-32B

WMMS-4X12C-32B

WMMS-3X0912C-32B

WMMS-3X1209C-32B

WMMS-2X(0912)C-34B

Wall Mount Mini -Basic Split 
Systems-Single & Multiple Zones

13 SEER

R410A 

SYSTEM COMPONENTS-GENERAL

INDOOR UNIT

Air Inlet

Air Intake Grilles

Temperature Sensor

Indicating Lamp &
Signal Receiving
Window

Emergency Switch

Horizontal Louver

Vertical Louver

Air Outlet

Air Filter

Remote Control

Air Inlet   

Connecting Pipe 
and Cable

Drainage Hose

Air Outlet

OUTDOOR UNIT

The figures in this manual are based on the external view of a standard model.
Consequently, the shape or appearance may differ from that of the air conditioner you have 
selected.

P15 OF 34

P16 OF 34

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

Содержание M2 SERIES

Страница 1: ...designed and manufactured free from defects in material and workmanship under the normal use and maintenance Installation operation maintenance and service shall follow professional practices for reg...

Страница 2: ...Damage to Unit People Properties and Others Resulted from Such Behaviour Following NEC State and Local Codes and Installation Instructions of All Units Otherwise Unit Warranty Will Be Void and Seriou...

Страница 3: ...itch to outdoor unit 9 The size of HVAC circuit breaker fuse or disconnect switch to the outdoor unit 11 What is the refrigerant pipe length between each indoor unit and the outdoor unit Unit A Unit B...

Страница 4: ...Sears etc which the manufacturer may not require licensed personnel to install Reading and following the YMGI Group recommendations suggestions and requirements written in the following pages and oth...

Страница 5: ...BRIEF UNIT INFO BRIEF UNIT INFO P8 OF 34 P7 OF 34 1 The YMGI Limited Product Warranty Policy details the eligibilities coverage s and other explanations of the warranty terms between YMGI group and t...

Страница 6: ...t Green World YMGI Engineered Comfort Products for A Sustainable and Efficient Green World If the damage is minor or partial that you choose to accept you can contact the distributor or YMGI to discus...

Страница 7: ...m and fill all fields appropriately sign and send back to the YMGI Group 3 Once the form has been completed and sent back to YMGI remove the units and ship back to YMGI Please make a note describing t...

Страница 8: ...ting Needs and Actual Part Availability Reason Unit Appearance Subject to Change or Update Continuously without Prior Notice Outdoor unit s provides the electrical and thermal power for the whole syst...

Страница 9: ...MS 2X30C 32B WMMS 2X09K 34B WMMS 0912K 34B WMMS 2X12K 34B WMMS 2X18K 34B WMMS 2X24K 34B WMMS 2X30K 34B WMMS 09E F 34B WMMS 09 12E F 34B WMMS 12E F 34B WMMS 18E F 34B WMMS 24E F 34B WMMS 30E F 34B WMMS...

Страница 10: ...100mm 4 SYSTEM COMPONENTS INSTALLATION CLEARANCE DUAL ZONE OVER 500mm 20 Outdoor unit OVER 50mm 2 OVER 100mm 4 OVER 2000mm 80 Indoor unit A OVER 100mm 4 Indoor unit B CLEARANCE REQUIRED AROUND UNITS S...

Страница 11: ...STRUCTION INSTALLER S INSTRUCTION P20 OF 34 P19 OF 34 SYSTEM COMPONENTS INSTALLATION CLEARANCE TRIPLE ZONE SYSTEM COMPONENTS INSTALLATION CLEARANCE QUAD ZONE YMGI Engineered Comfort Products for A Sus...

Страница 12: ...Optional Wall Thermostat UNIT OPERATION INSTALLER S INSTRUCTION P22 OF 34 P21 OF 34 Heating mode Sleep mode Dry mode Fan mode Set temperature Status indicating bar 2 bar indicator POWER ON Cooling mod...

Страница 13: ...t of SLEEP mode When SLEEP button is pressed star moon sign either shows up or goes off If star moon sign is ON MODE turns into SLEEP mode see related function change separately if pressed again star...

Страница 14: ...NCEL E HEAT MODE Pointing remote line control to the unit press MODE button until HEAT is shown In this mode you can press FAN SPEED button to change the fan speed of indoor unit Press TEMPERATURE ADJ...

Страница 15: ...Prior to Using the Unit Regular Air Filter Deodorization Filter orAir Cleaner must be cleaned once a while depending upon air quality and unit application Open Front Panel only After Unit Stops Runni...

Страница 16: ...wait a little while Pressed ON OFF too many times Press it firmly to check if the indoor unit beeps DOUBTING ABOUT UNIT FAILURE Phenomenon Analysis and Solution Indoor unit fan stops for about 10 min...

Страница 17: ...ep the manual and look up in the manuals for the correct understanding how the unit will work and how to operate the unit correctly Any problems due to improper maintenance of the air conditioner heat...

Страница 18: ...have seen as a unit history No Date Service Maintenance Conducted Person Phone USER NOTES Put down whatever questions you have or problems you have seen as a unit history No Date Questions or Problems...

Отзывы: