YMGI M2 SERIES Скачать руководство пользователя страница 17

W

ARRANTY

 &

SUPPORT

UNIT MAINTENANCE & 

SER

VICE GUIDE

P32 OF 34

P31 OF 34

WARRANTY AND TECH. SUPPORT

YMGI warrants to the purchaser/owner(s) that YMGI products be free from defects in material and 
workmanship under the normal use and maintenance, with the standard Limited Product Warranty 
Policies that comes with the unit or sales package.

YMGI IS NOT RESPONSIBLE FOR

CONTACT FOR FIELD SERVICE OR REPAIR

The following people, in a prioritized sequence, will take care of your request or issue:
1) The original installer; otherwise,
2) Your current service contractor; otherwise,
3) Authorized contractor in YMGI list that is close to you; otherwise,
4) Authorized Distributor in YMGI Distributor list; otherwise,
5) Contractor/Distributor you prefer who is close to you.

CONTACT FOR GENERAL TECHNICAL QUESTIONS OR SUPPORT, IN A SEQUENCE:

1) The original installer; otherwise,
2) The current service contractor; otherwise,

3) The distributor; where the unit is purchased from otherwise,
4) YMGI Technical Support:
    Tel: (866) 833-3138*703          Email: [email protected]

* Regular equipment maintenance or field service or field inspection.

* Damage or repairs required as a consequence Customer do-it-yoursely(DIY) installation and/or any other faulty 
   installation or improper application.

* Failure to start due to voltage conditions, blown fuses, open circuit breakers, or other damages due to the 
  inadequacy or interruption of electrical service.

* Damage or repairs needed as a consequence of any misapplication, abuse, improper servicing, unauthorized 
  alteration, or improper operation.
* Damage as a result of floods, winds, fires, lightening, accidents, corrosive atmosphere, or other conditions 
  beyond the control of YMGI.

* Parts not supplied or designated by YMGI.
* Products installed outside USA or Canada.

* Any damages to person or property of whatever kind, direct or indirect, special or consequential, whether 
  resulting from use or loss of use of the product.

The original licensed installer or current service contractor should be contacted first of all, since they installed 
the unit and/or know more details than anybody else.
They will check the unit and find out the problems with the professional knowledge about HVAC and electric 
product installation by using special tools or instrument.
They can contact YMGI technical support for technical help during unit installation or inspection.
Product model and serial numbers needed, which can be found on unit nameplate sticker, so that our 
technician can quickly identify the unit, parts and wiring diagrams, among our many products and models.

* Any problems due to improper cooling and heating load calcuation of the room/building the air conditioner/heat 
  pump system is to be installed. Equipment users can get the calculation schedule from your room/building 
  architect or your installation or related service HVAC contractor, who should have knowledge and tools to do 
  these calculation correctly.
* Any problems due to improper sizing and selecting air conditioner/heat pump system. These equipment sizing 
  and selection work should be conducted by either your room/building architect or your installation or related 
  service HVAC contractor, who should have knowledge and tools to do these calculation correctly, and get your 
  approval, before your purchasing these air conditioner or heat pump equipment.
* Any problems due to improper installing of the air conditioner/heat pump system. Installation should be 
  conducted by currently licensed HVAC technician, following manufacturer installation instructions, all governing 
  safety codes, with care and professionalism. 
* Any problems due to improper operation of the air conditioner/heat pump system. Users shall keep the manual 
  and look up in the manuals for the correct understanding how the unit will work and how to operate the unit 
  correctly.
* Any problems due to improper maintenance of the air conditioner/heat pump system. Like a car, regular 
  maintenance or yearly checking is necessary for the unit to work properly for you, before the season comes. For 
  example, air filter shall be checked for cleaness from time to time. Remote control batteries shall be checked for 
  enough power, before judging the unit is not working...

DIAGONSIS CODE, POSSIBLE CLAUSES, AND SUGGESTED ACTIONS TO 
USER AND TECHNICIAN

DIAGNOSIS CODE & TROUBLE-SHOOTING GUIDELINE

Codes

Descriptions

Possible Reasons

Suggestion to User

Technician Trouble-Shooting

E1

Condensate Full in drain pan

Dain pan dirty, drain hose 
clogging, water level switch 
failure, loose connection, 
bad control board/
components, etc.

Check if drain hose is 
clogged; if not, need to call 
your installing or service 
technician.

E2

Indoor air temp. sensor failure

Bad temperature sensor; 
loose connection, damaged 
wires, bad control board/
components, etc.

E3

Indoor coil copper tube 
sensor failure

Bad temperature sensor; 
loose connection, damaged 
wires, bad control board/
components, etc.

Lift up grille/cover, to check 
if the sensor looks bad or 
drops out of holding socket/
pocket; or, to call installing 
or service technician.

E4

Abnormal cooling

E5

Abnormal heating

Dirty filters/coils, refrigerant 
leaks over time, pipe too 
long, kinks or clogging in 
pipe line or valves, pipe 
damage, sensor failure, 
compressor or board or 
other component failures, 
etc.

1) Regularly check and
    clean indoor unit filters, 
    indoor and outdoor coils.

2) The service valves at
    outdoor unit should be 
    generally cool at cooling 
    mode, hot at heating 
    mode;

3) Call your installing or
    service technician to 
    check unit.

E6

Cooling-outdoor coil low 
temp. protection

Outdoor too cold to run 
cooling mode, windy, too 
much refrigerant, short 
piping, etc.

E7

Cooling-Indoor coil anti-
freeze protection

Dirty filter/coils, indoor fan 
motor failure, loose blower 
wheel/motor connection, too 
much or less refrigerant, 
pipe/cap. tube/valve 
clogging, etc.

E8

Heating-outdoor coil high 
temp. protection

Outdoor temperature too 
warm to run heating mode, 
too much refrigerant, short 
piping, etc.

E9

Heating-indoor coil anti-to 
hot protection

Dirty filter/coils, indoor fan 
motor failure, loose blower 
wheel/motor connection, too 
much refrigerant, pipe/cap. 
tube/valve clogging, etc.

E0

Heating-outdoor coil too 
cold protection

Outdoor temperature is too 
cold to run heat pump/
heating.

1) Shut off the unit;

2) Cooling, wait until 
    weather allows the unit 
    to re-start, or switch to 
    alternative cooling 
    equipment which allows 
    lower ambient cooling;

3) Heating, wait until 
    weather allows the unit 
    to re-start, or switch to 
    base-board heater, gas 
    furnace or other 
    alternative heating 
    sources during cold 
    hours/days.

1) Check if these are
    caused by installation or 
    component failure;

2) There could be nothing 
    abnormal, but the unit is 
    at protection mode, which 
    means the current 
    ambient temperature is 
    not proper to run the unit;

3) If there is something
    wrong, need to find all 
    the clauses and correct 
    or fix the problems and 
    not to leave any bugs.

1) Shut off power;

2) Follow possible clauses 
    listed at the left, to check 
    one by one;

3) To save time for quick 
    diagnosis as much as 
    posible, suggest your 
    technician to make 
    appointment with YMGI 
    tech. support, and call us  
    while the techician is at 
    job site. 

4)  Better to check the unit, 
    get problems and model 
    model #, and serial # 
    ready, before calling 
    YMGI tech. support.

5) Need the technician 
    physically, at the job site, 
    use right tools and 
    experience, to find all the 
    clauses and correct or fix 
    the problems and not to 
    leave any bugs.

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

Содержание M2 SERIES

Страница 1: ...designed and manufactured free from defects in material and workmanship under the normal use and maintenance Installation operation maintenance and service shall follow professional practices for reg...

Страница 2: ...Damage to Unit People Properties and Others Resulted from Such Behaviour Following NEC State and Local Codes and Installation Instructions of All Units Otherwise Unit Warranty Will Be Void and Seriou...

Страница 3: ...itch to outdoor unit 9 The size of HVAC circuit breaker fuse or disconnect switch to the outdoor unit 11 What is the refrigerant pipe length between each indoor unit and the outdoor unit Unit A Unit B...

Страница 4: ...Sears etc which the manufacturer may not require licensed personnel to install Reading and following the YMGI Group recommendations suggestions and requirements written in the following pages and oth...

Страница 5: ...BRIEF UNIT INFO BRIEF UNIT INFO P8 OF 34 P7 OF 34 1 The YMGI Limited Product Warranty Policy details the eligibilities coverage s and other explanations of the warranty terms between YMGI group and t...

Страница 6: ...t Green World YMGI Engineered Comfort Products for A Sustainable and Efficient Green World If the damage is minor or partial that you choose to accept you can contact the distributor or YMGI to discus...

Страница 7: ...m and fill all fields appropriately sign and send back to the YMGI Group 3 Once the form has been completed and sent back to YMGI remove the units and ship back to YMGI Please make a note describing t...

Страница 8: ...ting Needs and Actual Part Availability Reason Unit Appearance Subject to Change or Update Continuously without Prior Notice Outdoor unit s provides the electrical and thermal power for the whole syst...

Страница 9: ...MS 2X30C 32B WMMS 2X09K 34B WMMS 0912K 34B WMMS 2X12K 34B WMMS 2X18K 34B WMMS 2X24K 34B WMMS 2X30K 34B WMMS 09E F 34B WMMS 09 12E F 34B WMMS 12E F 34B WMMS 18E F 34B WMMS 24E F 34B WMMS 30E F 34B WMMS...

Страница 10: ...100mm 4 SYSTEM COMPONENTS INSTALLATION CLEARANCE DUAL ZONE OVER 500mm 20 Outdoor unit OVER 50mm 2 OVER 100mm 4 OVER 2000mm 80 Indoor unit A OVER 100mm 4 Indoor unit B CLEARANCE REQUIRED AROUND UNITS S...

Страница 11: ...STRUCTION INSTALLER S INSTRUCTION P20 OF 34 P19 OF 34 SYSTEM COMPONENTS INSTALLATION CLEARANCE TRIPLE ZONE SYSTEM COMPONENTS INSTALLATION CLEARANCE QUAD ZONE YMGI Engineered Comfort Products for A Sus...

Страница 12: ...Optional Wall Thermostat UNIT OPERATION INSTALLER S INSTRUCTION P22 OF 34 P21 OF 34 Heating mode Sleep mode Dry mode Fan mode Set temperature Status indicating bar 2 bar indicator POWER ON Cooling mod...

Страница 13: ...t of SLEEP mode When SLEEP button is pressed star moon sign either shows up or goes off If star moon sign is ON MODE turns into SLEEP mode see related function change separately if pressed again star...

Страница 14: ...NCEL E HEAT MODE Pointing remote line control to the unit press MODE button until HEAT is shown In this mode you can press FAN SPEED button to change the fan speed of indoor unit Press TEMPERATURE ADJ...

Страница 15: ...Prior to Using the Unit Regular Air Filter Deodorization Filter orAir Cleaner must be cleaned once a while depending upon air quality and unit application Open Front Panel only After Unit Stops Runni...

Страница 16: ...wait a little while Pressed ON OFF too many times Press it firmly to check if the indoor unit beeps DOUBTING ABOUT UNIT FAILURE Phenomenon Analysis and Solution Indoor unit fan stops for about 10 min...

Страница 17: ...ep the manual and look up in the manuals for the correct understanding how the unit will work and how to operate the unit correctly Any problems due to improper maintenance of the air conditioner heat...

Страница 18: ...have seen as a unit history No Date Service Maintenance Conducted Person Phone USER NOTES Put down whatever questions you have or problems you have seen as a unit history No Date Questions or Problems...

Отзывы: