YMGI LIT-WMMS-(56)-DC IVTR Скачать руководство пользователя страница 8

INST

ALLER'S 

INSTRUCTION

P14 OF 38

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

INSTALLATION ILLUSTRATION

Air out

Drainage hose

Connection pipe

Indoor unit

Outdoor unit

Display icon (May vary open models):

Air wall sleeve

Guide panel

Filter

Bolt

Nut

Wrench

Notes: Actual unit/ part looking and 
installation may vary from the illustrated.
Subject to continuous improvement 
and change without prior notice.

Wrapping Tape

Wall Plpe

Wireless remote control

Displayer

Air Inlet

Front Panel

Recelver

Power/Run

Cooling

Heating

Set temp.

Dehumidify

Air in

INST

ALLER'S 

INSTRUCTION

P13 OF 38

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

1) Mounting Indoor & Outdoor 
    Units and Running 
    Piping/Wiring

Ruler (Not Shown)
Stud-Finder
Dry-Wall Saw
Electric Drill
3" Hole Saw
Drill Extension
Hammer Drill and Bit (Not Shown)
Measuring Tape
Level
Flash Light
Screw Driver (Phillps and Flat)
Hammer
Knife
Scissors
Goggled Glass
Mask
Gloves
Ladder

2) Refrigeration Related Work

3) Electrical Related Installation

Wire Cutter
Wire Stripper
Sharp Plier
Cable Ties
Black Tape for Electrical Use
lectrical Meter

Clamp Meter (Not Shown)
Manifold
Infra Thermometer (Not Shown)

4) Trial Running Units and 
Inspection

RECOMMENDED TOOLS FOR INSTALLATION

Individual Wrentch Set (Use Two at 
One Time)
Flare-Nut Tool Set (Not Shown)
Hex Head Allen Wrentch Sets (Metric 
and Imperial)
Brazing Rods and Brazing Torch 
Outfit for AC Application (Not Shown)
Brazing Flux
Nitrogen Cylinder for Positive 
Pressure Leakage Check (Not Shown)
Soap Bubble for Positive Pressure 
Leakage Check (Not Shown)
Vacuum Pump for Negative Pressure 
Leakage Check 
Helium Refrigerant Minor Leakage 
Check (Not Shown)
Manifold

Содержание LIT-WMMS-(56)-DC IVTR

Страница 1: ...igroup com This product is designed and manufactured free from defects in material and workmanship for normal use and maintenance Installation operation maintenance and service shall follow profession...

Страница 2: ...MGI technical support division directly at Dear Customer s End User s Unit Purchaser s Installer s Contractor s Thanks for choosing YMGI products The YMGI equipment you purchased is either a split typ...

Страница 3: ...e humidity ranges installation operation maintenance service warranty parts and so on 4 Properly select correct most suitable YMGI product models of units and accessories for your HVAC applications jo...

Страница 4: ...he installation 5 Supply electrical power V Ph Hz measured at wiring terminal block of Indoor unit outdoor unit 7 Wire gauge length and terminal colors between circuit breaker disconnect switch to out...

Страница 5: ...ls to do these calculations correctly and get your approval before purchasing the air conditioner or heat pump equipment Any problems due to improper installing of the air conditioner heat pump system...

Страница 6: ...ing the air conditioner for a long time Otherwise the accumulated dust may cause fire or electric shock Select the most appropriate temperature Don t leave windows and doors open for a long time while...

Страница 7: ...lities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety 5 Children should be supervis...

Страница 8: ...r Not Shown Stud Finder Dry Wall Saw Electric Drill 3 Hole Saw Drill Extension Hammer Drill and Bit Not Shown Measuring Tape Level Flash Light Screw Driver Phillps and Flat Hammer Knife Scissors Goggl...

Страница 9: ...PIPE 1 For well draining the drain hose should be placed at a downward slant 2 Do not wrench or bend the drain hose or flood its end by water 3 When the long drainage hose passing through indoor shoul...

Страница 10: ...ing the electric wire if the wire length is not enough please contact with the authorized service shop to buy a exclusive electric wire that is long enough and the joint on the wire are not allowed Th...

Страница 11: ...AWG 12 and it should accord with UL4703 2 The MC 4 connectors should be assembled to the PV wires and the other side of the PV wires should be assembled with spade terminals ASSEMBLY OF MC 4 CONNECTO...

Страница 12: ...the operation 2 Press MODE button to select the COOL HEAT not available for cooling only unit is FAN and so on to check All the functions to make sure the unit functions correctly and properly Refrig...

Страница 13: ...URBO MODE INCREASE Temp Time TIMER ON TIMER OFF LIGHT SLEEP TEMP U TOUCH NOT USED NOTE2 Be sure there are no obstructions between the indoor unit and the remote control Do not drop or allow any liquid...

Страница 14: ...emote press the TIMER ON button once more and the word ON will stop blinking and stay on the remote The time you would like the unit to turn on is now set TIMER OFF BUTTON This allows you to set the t...

Страница 15: ...he change of swing status will also depend on the circulation sequence stated above About swing up and down Press and buttons simultaneously to lock or unlock the keyboard If the remote controller is...

Страница 16: ...isconnect the electrical power at outdoor unit Before cleaning the unit t Never sprinkle water on the indoor unit and the outdoor unit Volatile liquid gasoline or the like will damage the unit So wipe...

Страница 17: ...essure refrigerant and oil and line voltage The copper lines must be installed properly to prevent leakage and foreign substances from contaminating the refrigerant system 2 You will save money in the...

Страница 18: ...rior to paying the contractor in full The cost of not having your unit installed properly can be more expensive than spending a little extra money that hiring the right contractor will cost Protect yo...

Страница 19: ...ur unit We will be happy to assist you with any questions you may have concerning the functions of your new unit 1 Part repair or replacement after trouble shooting This is the most common and general...

Страница 20: ...r installation instruction manual or come separately in the unit packaging box envelope If for any reason they are not included with your shipment contact our sales or customer service to request a co...

Страница 21: ...P39 OF 40 YMGI Engineered Comfort Products for A Sustainable and Efficient Green World P40 OF 40 YMGI Engineered Comfort Products for A Sustainable and Efficient Green World...

Отзывы: