Yingli Solar PV Modules, Installation and User Manual
page 8
This supplement refers to modules of the follwing types:
FAMILY
YGE 60 Cell SERIES
&
YGE-Z 60 Cell SERIES
YGE 72 Cell SERIES
YGE 72 Cell NH SERIES
PANDA 48 Cell SERIES
PANDA 60 Cell SERIES
TYPE
YL230P-29b
YL280P-35b
YL180C-24b
YL225C-30b
YL235P-29b
YL285P-35b
YL185C-24b
YL230C-30b
YL240P-29b
YL290P-35b
YL190C-24b
YL235C-30b
YL245P-29b
YL295P-35b
YL195C-24b
YL240C-30b
YL250P-29b
YL300P-35b
YL200C-24b
YL245C-30b
YL255P-29b
YL305P-35b
YL205C-24b
YL250C-30b
YL260P-29b
YL310P-35b
YL210C-24b
YL255C-30b
YL265P-29b
YL315P-35b
YL215C-24b
YL260C-30b
YL265C-30b
YL270C-30b
M O U N T I N G R E Q U I R E M E N T S
Mounting Method Option A: Bolts or clamps
Modules that Require
Four (4) Connection Points
The Following Modules Require Six (6) Con-
nection Points for Installations that Exceed 50
psf (2400 Pa) Loading
YGE 60 Cell SERIES & YGE-Z 60 Cell
SERIES
YGE 72 Cell NH SERIES
YGE 72 Cell SERIES*
PANDA 60 Cell SERIES & PANDA 60
Cell SERIES
* Connections are required at the four outer mounting holes
E L E C T R I C A L C H A R AC T E R I S T I C S
Nameplate ratings are average values. The electrical characteristics are /- 10 percent of the indicated values of Isc, Voc, and Pmax under Standard Test
Conditions (irradiance of 1000 W/m2, AM 1.5 spectrum, and a cell temperature of 25ºC). Refer to module datasheets for specific power output tolerance.
Module
family
Module
type
Power
output
Voltage at
Pmax
Current at
Pmax
Open-circuit voltage
Short-circuit current
Max. DC system
voltage
Max. series fuse
rating
P
max
V
mpp
I
mpp
V
oc
I
sc
[W]
[V]
[A]
[V]
[A]
[V]
[A]
YGE 60 Cell
SERIES&YGE-Z 60
Cell SERIES
YL265P-29b
265
30.5
8.70
37.8
9.18
1000
15
YL260P-29b
260
30.3
8.59
37.7
9.09
1000
15
YL255P-29b
255
30.0
8.49
37.7
9.01
1000
15
YL250P-29b
250
29.8
8.39
37.6
8.92
1000
15
YL245P-29b
245
29.6
8.28
37.5
8.83
1000
15
YL240P-29b
240
29.3
8.18
37.5
8.75
1000
15
YL235P-29b
235
29.1
8.08
37.4
8.66
1000
15
YL230P-29b
230
28.9
7.97
37.3
8.57
1000
15
YGE 72 Cell
NH SERIES
YL315P-35b
315
36.8
8.56
45.7
9.12
1000
15
YL310P-35b
310
36.3
8.53
45.6
8.99
1000
15
YL305P-35b
305
36.1
8.45
45.4
8.93
1000
15
YL300P-35b
300
35.8
8.37
45.2
8.86
1000
15
YL295P-35b
295
35.6
8.29
45.0
8.79
1000
15
YL290P-35b
290
35.3
8.22
44.8
8.73
1000
15
YL285P-35b
285
35.0
8.14
44.6
8.66
1000
15
YL280P-35b
280
34.7
8.06
44.4
8.59
1000
15
Module Supplement
YINGLI SOLAR
Installation Method: Zep Solar Mounting Systems
ZSI, ZSII
YGE-Z 60 Cell SERIES*